Fully automatic segmentation of arbitrarily shaped fiducial markers in cone-beam CT projections

被引:16
作者
Bertholet, J. [1 ]
Wan, H. [2 ]
Toftegaard, J. [1 ]
Schmidt, M. L. [1 ]
Chotard, F. [1 ,3 ]
Parikh, P. J. [2 ]
Poulsen, P. R. [1 ]
机构
[1] Aarhus Univ Hosp, Dept Oncol, Aarhus, Denmark
[2] Washington Univ, Sch Med, Dept Radiat Oncol, St Louis, MO USA
[3] Polytech Nantes, Nantes, France
关键词
image-guided radiotherapy; fiducial markers; marker segmentation; KILOVOLTAGE; MOTION; RADIOTHERAPY; TARGETS; THERAPY; IMAGES;
D O I
10.1088/1361-6560/aa52f7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Radio-opaque fiducial markers of different shapes are often implanted in or near abdominal or thoracic tumors to act as surrogates for the tumor position during radiotherapy. They can be used for real-time treatment adaptation, but this requires a robust, automatic segmentation method able to handle arbitrarily shaped markers in a rotational imaging geometry such as cone-beam computed tomography (CBCT) projection images and intra-treatment images. In this study, we propose a fully automatic dynamic programming (DP) assisted template-based (TB) segmentation method. Based on an initial DP segmentation, the DPTB algorithm generates and uses a 3D marker model to create 2D templates at any projection angle. The 2D templates are used to segment the marker position as the position with highest normalized crosscorrelation in a search area centered at the DP segmented position. The accuracy of the DP algorithm and the new DPTB algorithm was quantified as the 2D segmentation error (pixels) compared to a manual ground truth segmentation for 97 markers in the projection images of CBCT scans of 40 patients. Also the fraction of wrong segmentations, defined as 2D errors larger than 5 pixels, was calculated. The mean 2D segmentation error of DP was reduced from 4.1 pixels to 3.0 pixels by DPTB, while the fraction of wrong segmentations was reduced from 17.4% to 6.8%. DPTB allowed rejection of uncertain segmentations as deemed by a low normalized cross-correlation coefficient and contrast-to-noise ratio. For a rejection rate of 9.97%, the sensitivity in detecting wrong segmentations was 67% and the specificity was 94%. The accepted segmentations had a mean segmentation error of 1.8 pixels and 2.5% wrong segmentations.
引用
收藏
页码:1327 / 1341
页数:15
相关论文
共 12 条
[1]   Real-time segmentation of multiple implanted cylindrical liver markers in kilovoltage and megavoltage x-ray images [J].
Fledelius, W. ;
Worm, E. ;
Hoyer, M. ;
Grau, C. ;
Poulsen, P. R. .
PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (11) :2787-2800
[2]   Robust automatic segmentation of multiple implanted cylindrical gold fiducial markers in cone-beam CT projections [J].
Fledelius, Walther ;
Worm, Esben ;
Elstrom, Ulrik V. ;
Petersen, Jorgen B. ;
Grau, Cai ;
Hoyer, Morten ;
Poulsen, Per R. .
MEDICAL PHYSICS, 2011, 38 (12) :6351-6361
[3]   The first clinical treatment with kilovoltage intrafraction monitoring (KIM): A real-time image guidance method [J].
Keall, Paul J. ;
Ng, Jin Aun ;
O'Brien, Ricky ;
Colvill, Emma ;
Huang, Chen-Yu ;
Poulsen, Per Rugaard ;
Fledelius, Walther ;
Juneja, Prabhjot ;
Simpson, Emma ;
Bell, Linda ;
Alfieri, Florencia ;
Eade, Thomas ;
Kneebone, Andrew ;
Booth, Jeremy T. .
MEDICAL PHYSICS, 2015, 42 (01) :354-358
[4]   Automatic tracking of implanted fiducial markers in cone beam CT projection images [J].
Marchant, T. E. ;
Skalski, A. ;
Matuszewski, B. J. .
MEDICAL PHYSICS, 2012, 39 (03) :1322-1334
[5]   Kilovoltage Intrafraction Monitoring for Prostate Intensity Modulated Arc Therapy: First Clinical Results [J].
Ng, Jin Aun ;
Booth, Jeremy T. ;
Poulsen, Per R. ;
Fledelius, Walther ;
Worm, Esben Schjodt ;
Eade, Thomas ;
Hegi, Fiona ;
Kneebone, Andrew ;
Kuncic, Zdenka ;
Keall, Paul J. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (05) :E655-E661
[6]   A method for robust segmentation of arbitrarily shaped radiopaque structures in cone-beam CT projections [J].
Poulsen, Per Rugaard ;
Fledelius, Walther ;
Keall, Paul J. ;
Weiss, Elisabeth ;
Lu, Jun ;
Brackbill, Emily ;
Hugo, Geoffrey D. .
MEDICAL PHYSICS, 2011, 38 (04) :2151-2156
[7]   Automatic tracking of arbitrarily shaped implanted markers in kilovoltage projection images: A feasibility study [J].
Regmi, Rajesh ;
Lovelock, D. Michael ;
Hunt, Margie ;
Zhang, Pengpeng ;
Pham, Hai ;
Xiong, Jianping ;
Yorke, Ellen D. ;
Goodman, Karyn A. ;
Rimner, Andreas ;
Mostafavi, Hassan ;
Mageras, Gig S. .
MEDICAL PHYSICS, 2014, 41 (07)
[8]   Cardiac and respiration induced motion of mediastinal lymph node targets in lung cancer patients throughout the radiotherapy treatment course [J].
Schmidt, Mai Lykkegaard ;
Hoffmann, Lone ;
Knap, Marianne Marquard ;
Rasmussen, Torben Riis ;
Folkersen, Birgitte Holst ;
Toftegaard, Jakob ;
Moller, Ditte Sloth ;
Poulsen, Per Rugard .
RADIOTHERAPY AND ONCOLOGY, 2016, 121 (01) :52-58
[9]   Automated patient setup and gating using cone beam computed tomography projections [J].
Wan, Hanlin ;
Bertholet, Jenny ;
Ge, Jiajia ;
Poulsen, Per ;
Parikh, Parag .
PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (06) :2552-2561
[10]   Using dynamic programming to improve fiducial marker localization [J].
Wan, Hanlin ;
Ge, Jiajia ;
Parikh, Parag .