Energy Efficient Cooling in Data Center Using Optimization Approach

被引:0
|
作者
Nakamura, Masayuki [1 ]
Nakamura, Ryota [1 ]
Nishida, Ryuichi [2 ]
Takeuchi, Akira [1 ]
Tominaga, Tetsuya [1 ]
机构
[1] NTT Energy & Environm Syst Labs, Tokyo, Japan
[2] NTT FACILITIES INC, Tokyo, Japan
来源
2012 PROCEEDINGS OF SICE ANNUAL CONFERENCE (SICE) | 2012年
关键词
data centers; energy efficiency; optimization; thermal control;
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
This paper presents an optimal cooling approach to minimize the power consumption of computer room air conditioners in data centers. A temperature control experiment was conducted in a simulated data center. Based on the experimental data, temperature and power consumption models are introduced to formulate an optimization problem. The resulting coordinated control led to a power consumption reduction. The simulation results indicate that the proposed optimization approach resulted in 6% to 14% less power consumption than that of a baseline control.
引用
收藏
页码:2103 / 2108
页数:6
相关论文
共 50 条
  • [1] Learning and Optimization Models for Energy Efficient Cooling Control in Data Center
    Nakamura, Masayuki
    2016 55TH ANNUAL CONFERENCE OF THE SOCIETY OF INSTRUMENT AND CONTROL ENGINEERS OF JAPAN (SICE), 2016, : 395 - 400
  • [2] Energy Efficient Approach using Server Virtualization in Cloud Data Center
    Desa, Mohd Shukri Bin Md
    Samuel, Joshua
    Elango, Sangeetha
    Johari, Zainudin
    Stephen, Daniel M.
    2018 IEEE 4TH INTERNATIONAL SYMPOSIUM IN ROBOTICS AND MANUFACTURING AUTOMATION (ROMA), 2018,
  • [3] Optimization of data-center immersion cooling using liquid air energy storage
    Liu, Chuanliang
    Hao, Ning
    Zhang, Tianbo
    Wang, Dexuan
    Li, Zhenya
    Bian, Wenjie
    JOURNAL OF ENERGY STORAGE, 2024, 90
  • [4] Increase energy efficiency of data center cooling facilities with airflow optimization
    Buchholz, Jochen
    Sandoval, Yosandra
    Volk, Eugen
    2013 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC 2013), 2013, : 4439 - 4443
  • [5] Energy Conservation Approach for Data Center Cooling Using Heat Pipe Based Cold Energy Storage System
    Wu, Xiao Ping
    Mochizuki, Masataka
    Mashiko, Koichi
    Thang Nguyen
    Wuttijumnong, Vijit
    Cabsao, Gerald
    Singh, Randeep
    Akbarzadeh, Aliakbar
    26TH ANNUAL IEEE SEMICONDUCTOR THERMAL MEASUREMENT AND MANAGEMENT SYMPOSIUM, PROCEEDINGS 2010, 2010, : 115 - 122
  • [6] Energy Efficient and Lower Capital Cost - an Alternative Data Center Cooling Strategy
    Hughes, Phil
    Tschudi, William
    ASHRAE TRANSACTIONS 2011, VOL 117, PT 2, 2011, 117 : 34 - 42
  • [7] Detecting Data Center Cooling Problems Using a Data-driven Approach
    Chen, Charley
    Wang, Guosai
    Sun, Jiao
    Xu, Wei
    9TH ASIA-PACIFIC SYSTEMS WORKSHOP 2018 (APSYS'18), 2018,
  • [8] Optimization on Ports Activation Towards Energy Efficient Data Center Networks
    Chkirbene, Zina
    Hamila, Ridha
    Foufou, Sebti
    Kiranyaz, Serkan
    Gabbouj, Moncef
    UBIQUITOUS NETWORKING, UNET 2018, 2018, 11277 : 155 - 166
  • [9] Particle based Optimization for Predictive Energy Efficient Data Center Management
    Carnerero, A. D.
    Ramirez, D. R.
    Limon, D.
    Alamo, T.
    2020 59TH IEEE CONFERENCE ON DECISION AND CONTROL (CDC), 2020, : 2660 - 2665
  • [10] Energy Efficient Data Center
    Bieswanger, Andreas
    Hamann, Hendrik F.
    Wehle, Hans-Dieter
    IT-INFORMATION TECHNOLOGY, 2012, 54 (01): : 17 - 23