The use of the GuideLiner™ catheter as a child-in-mother technique: an initial single-center experience

被引:9
作者
Dardas, Petros S. [1 ]
Mezilis, Nikos [1 ]
Ninios, Vlasis [1 ]
Tsikaderis, Dimitrios [1 ]
Theofilogiannakos, Efstratios K. [1 ]
机构
[1] St Lukes Hosp, Thessaloniki Heart Inst, Dept Cardiol, Thessaloniki 54250, Greece
关键词
Percutaneous coronary interventions; GuideLiner (TM) catheter; Child-in-mother guide extension; PERCUTANEOUS CORONARY INTERVENTION; ELUTING STENTS; ARTERIES; LESIONS; TERM;
D O I
10.1007/s00380-011-0181-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Recently, a new interventional guide catheter, the GuideLiner (TM) catheter, was introduced into the market as a strategy for tackling the problem of stent delivery failure. We implemented this simplified child-in-mother technique in a series of 16 challenging coronary interventions. Balloon and stent delivery was successfully achieved in all cases and the device was both simple to deploy and remove. Apart from two cases of vessel dissection that were managed successfully with stent implantation, no other serious procedural complications were reported.
引用
收藏
页码:535 / 540
页数:6
相关论文
共 11 条
[1]   Stenting alone versus debulking and debulking plus stent in branch ostial lesions of native coronary arteries [J].
Chung, CM ;
Nakamura, S ;
Tanaka, K ;
Tanigawa, J ;
Kitano, K ;
Akiyama, T ;
Matoba, Y ;
Katoh, O .
HEART AND VESSELS, 2004, 19 (05) :213-220
[2]   Efficacy of paclitaxel-eluting stent implantation in hemodialysis patients [J].
Higashitani, Michiaki ;
Mori, Fumiaki ;
Yamada, Norihiro ;
Arashi, Hiroyuki ;
Kojika, Asako ;
Hoshi, Hiromi ;
Minami, Yuichiro ;
Yamaguchi, Junichi ;
Yamauchi, Takao ;
Takagi, Atsushi ;
Ogawa, Hiroshi ;
Hagiwara, Nobuhisa .
HEART AND VESSELS, 2011, 26 (06) :582-589
[3]   When one won't do it, use two - Double "buddy" wiring to facilitate stent advancement across a highly calcified artery [J].
Jafary, FH .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2006, 67 (05) :721-723
[4]  
Kumar S, 2010, J INVASIVE CARDIOL, V22, P495
[5]   Distal Stent Delivery With Guideliner Catheter: First in Man Experience [J].
Mamas, Mamas A. ;
Fath-Ordoubadi, Farzin ;
Fraser, Douglas G. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 76 (01) :102-111
[6]   Rotablation in the Drug Eluting Era: Immediate and Long-Term Results from a Single Center Experience [J].
Mezilis, Nick ;
Dardas, Petros ;
Ninios, Vlasis ;
Tsikaderis, Dimitrios .
JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2010, 23 (03) :249-253
[7]   Sirolimus- vs paclitaxel-eluting stents in de novo coronary artery lesions - The REALITY trial: A randomized controlled trial [J].
Morice, MC ;
Colombo, A ;
Meier, B ;
Serruys, P ;
Tamburino, C ;
Guagliumi, G ;
Sousa, E ;
Stoll, HP .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 295 (08) :895-904
[8]   Stent deployment failure: Reasons, implications, and short- and long-term outcomes [J].
Nikolsky, E ;
Gruberg, L ;
Pechersky, S ;
Kapeliovich, M ;
Grenadier, E ;
Amikam, S ;
Boulos, M ;
Suleiman, M ;
Markiewicz, W ;
Beyar, R .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 59 (03) :324-328
[9]   Percutaneous coronary intervention for unprotected left main disease in very high risk patients: safety of drug-eluting stents [J].
Pepe, Martino ;
Napodano, Massimo ;
Tarantini, Giuseppe ;
Fraccaro, Chiara ;
Cutolo, Ada ;
Peluso, Diletta ;
Isabella, Giambattista ;
Ramondo, Angelo ;
Iliceto, Sabino .
HEART AND VESSELS, 2011, 26 (01) :17-24
[10]  
Rao U, 2010, EUROINTERVENTION, V6, P277, DOI 10.4244/