Programmable Illumination and High-Speed, Multi-Wavelength, Confocal Microscopy Using a Digital Micromirror

被引:37
作者
Martial, Franck P. [1 ]
Hartell, Nicholas A. [1 ]
机构
[1] Univ Leicester, Dept Cell Physiol & Pharmacol, Leicester LE1 9HN, Leics, England
来源
PLOS ONE | 2012年 / 7卷 / 08期
基金
英国生物技术与生命科学研究理事会;
关键词
FLUORESCENT PROTEIN; DEVICE;
D O I
10.1371/journal.pone.0043942
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Confocal microscopy is routinely used for high-resolution fluorescence imaging of biological specimens. Most standard confocal systems scan a laser across a specimen and collect emitted light passing through a single pinhole to produce an optical section of the sample. Sequential scanning on a point-by-point basis limits the speed of image acquisition and even the fastest commercial instruments struggle to resolve the temporal dynamics of rapid cellular events such as calcium signals. Various approaches have been introduced that increase the speed of confocal imaging. Nipkov disk microscopes, for example, use arrays of pinholes or slits on a spinning disk to achieve parallel scanning which significantly increases the speed of acquisition. Here we report the development of a microscope module that utilises a digital micromirror device as a spatial light modulator to provide programmable confocal optical sectioning with a single camera, at high spatial and axial resolution at speeds limited by the frame rate of the camera. The digital micromirror acts as a solid state Nipkov disk but with the added ability to change the pinholes size and separation and to control the light intensity on a mirror-by-mirror basis. The use of an arrangement of concave and convex mirrors in the emission pathway instead of lenses overcomes the astigmatism inherent with DMD devices, increases light collection efficiency and ensures image collection is achromatic so that images are perfectly aligned at different wavelengths. Combined with non-laser light sources, this allows low cost, high-speed, multi-wavelength image acquisition without the need for complex wavelength-dependent image alignment. The micromirror can also be used for programmable illumination allowing spatially defined photoactivation of fluorescent proteins. We demonstrate the use of this system for high-speed calcium imaging using both a single wavelength calcium indicator and a genetically encoded, ratiometric, calcium sensor.
引用
收藏
页数:9
相关论文
共 16 条
  • [1] High-speed confocal laser scanning microscopy using acousto-optic deflectors and a digital micromirror device
    Bansal, V
    Patel, S
    Saggau, P
    [J]. THREE-DIMENSIONAL AND MULTIDIMENSIONAL MICROSCOPY: IMAGE ACQUISITION AND PROCESSING XI, 2004, 5 (13): : 47 - 54
  • [2] High-speed addressable confocal microscopy for functional imaging of cellular activity
    Bansal, Vivek
    Patel, Saumil
    Saggau, Peter
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (03)
  • [3] Callamaras N, 1999, METHOD ENZYMOL, V307, P152
  • [4] Optical sectioning microscopy
    Conchello, JA
    Lichtman, JW
    [J]. NATURE METHODS, 2005, 2 (12) : 920 - 931
  • [5] CALCIUM SIGNALING IN A NARROW SOMATIC SUBMEMBRANE SHELL DURING SYNAPTIC ACTIVITY IN CEREBELLAR PURKINJE NEURONS
    EILERS, J
    CALLEWAERT, G
    ARMSTRONG, C
    KONNERTH, A
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1995, 92 (22) : 10272 - 10276
  • [6] Whole-field fluorescence microscope with digital micromirror device: imaging of biological samples
    Fukano, T
    Miyawaki, A
    [J]. APPLIED OPTICS, 2003, 42 (19) : 4119 - 4124
  • [7] HAGEN G, 2007, P SPIE, V6441
  • [8] Hanley QS, 1999, J MICROSC-OXFORD, V196, P317, DOI 10.1046/j.1365-2818.1999.00602.x
  • [9] A dual path programmable array microscope (PAM): simultaneous acquisition of conjugate and non-conjugate images
    Heintzmann, R
    Hanley, QS
    Arndt-Jovin, D
    Jovin, TM
    [J]. JOURNAL OF MICROSCOPY-OXFORD, 2001, 204 (02): : 119 - 135
  • [10] Non-scanning fluorescence confocal microscopy using speckle illumination and optical data processing
    Jiang, SH
    Walker, JG
    [J]. OPTICS COMMUNICATIONS, 2005, 256 (1-3) : 35 - 45