The use of tunable diode laser absorption spectroscopy for the measurement of flame dynamics

被引:16
作者
Hendricks, AG [1 ]
Vandsburger, U [1 ]
Saunders, WR [1 ]
Baumann, WT [1 ]
机构
[1] Virginia Tech, Reacting Flows Lab, Dept Mech Engn 0238, Blacksburg, VA 24061 USA
关键词
flame dynamics; TDLAS; chemiluminescence;
D O I
10.1088/0957-0233/17/1/023
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Tunable diode laser absorption spectroscopy was used to measure temperature fluctuations in acoustically forced laminar and turbulent flames. The absorption of two high-temperature water lines, at 7444.37 cm(-1) (v1+v3 bands) and 7185.59 cm(-1) (2v1, v1+v3 bands), yielded an instantaneous temperature measurement of the product stream. The instantaneous temperature of the gases was used as an indicator of the energy transferred to the product stream from the combustion process. The frequency response of product gas temperature to velocity perturbations was compared to the frequency response of OH* chemiluminescence, an indicator of the chemical heat release rate. Past measurements of flame dynamics used chemiluminescence as the sole indicator of heat release rate, in effect assuming that the energy input rate from the flame into the acoustic field is dynamically equivalent to the chemical reaction rate. Through the use of TDLAS, the unsteady enthalpy of the gases was measured, which includes the effects of thermal diffusion and heat transfer. The measurements show that the frequency response function of gas temperature differs significantly from the chemiluminescence frequency response.
引用
收藏
页码:139 / 144
页数:6
相关论文
共 21 条
[1]   Diode laser absorption sensors for gas-dynamic and combustion flows [J].
Allen, MG .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1998, 9 (04) :545-562
[2]   ACTIVE CONTROL IN COMBUSTION SYSTEMS [J].
ANNASWAMY, AM ;
GHONIEM, AF .
IEEE CONTROL SYSTEMS MAGAZINE, 1995, 15 (06) :49-63
[3]  
[Anonymous], 1958, 4266 NACA
[4]   DUAL DIODE-LASER FIBEROPTIC DIAGNOSTIC FOR WATER-VAPOR MEASUREMENTS [J].
ARROYO, MP ;
BIRBECK, TP ;
BAER, DS ;
HANSON, RK .
OPTICS LETTERS, 1994, 19 (14) :1091-1093
[5]   ABSORPTION-MEASUREMENTS OF WATER-VAPOR CONCENTRATION, TEMPERATURE, AND LINE-SHAPE PARAMETERS USING A TUNABLE INGAASP DIODE-LASER [J].
ARROYO, MP ;
HANSON, RK .
APPLIED OPTICS, 1993, 32 (30) :6104-6116
[6]   DIODE-LASER ABSORPTION TECHNIQUE FOR SIMULTANEOUS MEASUREMENTS OF MULTIPLE GASDYNAMIC PARAMETERS IN HIGH-SPEED FLOWS CONTAINING WATER-VAPOR [J].
ARROYO, MP ;
LANGLOIS, S ;
HANSON, RK .
APPLIED OPTICS, 1994, 33 (15) :3296-3307
[7]   MULTIPLEXED DIODE-LASER SENSOR SYSTEM FOR SIMULTANEOUS H2O, O-2, AND TEMPERATURE-MEASUREMENTS [J].
BAER, DS ;
HANSON, RK ;
NEWFIELD, ME ;
GOPAUL, NKJM .
OPTICS LETTERS, 1994, 19 (22) :1900-1902
[8]   Scanned- and fixed-wavelength absorption diagnostics for combustion measurements using multiplexed diode lasers [J].
Baer, DS ;
Nagali, V ;
Furlong, ER ;
Hanson, RK ;
Newfield, ME .
AIAA JOURNAL, 1996, 34 (03) :489-493
[9]   ACTIVE CONTROL OF REHEAT BUZZ [J].
BLOXSIDGE, GJ ;
DOWLING, AP ;
HOOPER, N ;
LANGHORNE, PJ .
AIAA JOURNAL, 1988, 26 (07) :783-790
[10]   Diode-laser sensors for real-time control of pulsed combustion systems [J].
Furlong, ER ;
Mihalcea, RM ;
Webber, ME ;
Baer, DS ;
Hanson, RK .
AIAA JOURNAL, 1999, 37 (06) :732-737