Effect of corneal aberrations on intraocular lens power calculations

被引:26
作者
Canovas, Carmen [1 ,3 ]
Abenza, Salome [2 ]
Alcon, Encarna [1 ]
Villegas, Eloy A. [1 ]
Marin, Jose M. [2 ]
Artal, Pablo [1 ]
机构
[1] Univ Murcia, Lab Opt, Ctr Invest Opt & Nanofis, E-30001 Murcia, Spain
[2] Hosp Virgen Arrixaca, Serv Oftalmol, Murcia, Spain
[3] Abbott Med Opt, Groningen, Netherlands
关键词
IN-SITU KERATOMILEUSIS; CORRECT SPHERICAL-ABERRATION; REFRACTIVE SURGERY; CATARACT-SURGERY; HUMAN EYE; HOFFER-Q; FORMULA; MYOPIA; IOLS; PERFORMANCE;
D O I
10.1016/j.jcrs.2012.03.033
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To use ray tracing to determine the influence of corneal aberrations on the prediction of the optimum intraocular lens (IOL) power for implantation in normal eyes and eyes with previous laser in situ keratomileusis (LASIK). SETTING: Hospital Universitario Virgen de la Arrixaca, Murcia, Spain. DESIGN: Case series. METHODS: The optimum IOL power was calculated by ray tracing using a patient-customized eye model in cataract surgery cases. The calculation can be performed with or without inclusion of the patient's corneal aberrations. Standard predictions were also generated using current state-of-the-art IOL power calculation techniques. The results for all predictions were compared with the optimum IOL power after cataract surgery. RESULTS: For patients without previous LASIK (n = 18), the standard approaches and the ray-tracing procedure gave a similar mean absolute residual error and variance. The incorporation of corneal aberrations did not improve the accuracy of the ray-tracing prediction in these cases. For post-LASIK patients (n = 10), the ray-tracing prediction incorporating corneal aberrations generated the most accurate results. The difference between the prediction with and without considering corneal aberrations correlated with the amount of corneal spherical aberration (r(2) = 0.82), resulting in a difference of up to 3.00 diopters in IOL power in some cases. CONCLUSIONS: Ray tracing using patient-customized eye models was a robust procedure for IOL power calculation. The incorporation of corneal aberrations is crucial in post-LASIK eyes, primarily because of the elevated corneal spherical aberration.
引用
收藏
页码:1325 / 1332
页数:8
相关论文
共 40 条
[1]   Intraocular lens power calculation after corneal refractive surgery: Double-K method [J].
Aramberri, J .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (11) :2063-2068
[2]   Formula choice: Hoffer Q, Holladay 1, or SRK/T and refractive outcomes in 8108 eyes after cataract surgery with biometry by partial coherence interferometry [J].
Aristodemou, Petros ;
Cartwright, Nathaniel E. Knox ;
Sparrow, John M. ;
Johnston, Robert L. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (01) :63-71
[3]   History of IOLs that correct spherical aberration [J].
Artal, Pablo .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (06) :962-963
[4]   Laser In Situ Keratomileusis Disrupts the Aberration Compensation Mechanism of the Human Eye [J].
Benito, Antonio ;
Redondo, Manuel ;
Artal, Pablo .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (03) :424-431
[5]   Customized eye models for determining optimized intraocular lenses power [J].
Canovas, Carmen ;
Artal, Pablo .
BIOMEDICAL OPTICS EXPRESS, 2011, 2 (06) :1649-1663
[6]   The shape of the anterior and posterior surface of the aging human cornea [J].
Dubbelman, M ;
Sicarn, VADP ;
Van der Heijde, GL .
VISION RESEARCH, 2006, 46 (6-7) :993-1001
[7]   Validity of the keratometric index: Large population-based study [J].
Fam, Han-Bor ;
Lim, Kooi-Ling .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (04) :686-691
[8]   Intraocular lens power calculation after laser in situ keratomileusis for myopia and hyperopia - A standardized approach [J].
Feiz, V ;
Mannis, MJ ;
Garcia-Ferrer, F ;
Kandavel, G ;
Darlington, JK ;
Kim, E ;
Caspar, J ;
Wang, JL ;
Wang, W .
CORNEA, 2001, 20 (08) :792-797
[9]  
Guirao A, 2002, ARCH OPHTHALMOL-CHIC, V120, P1143
[10]   IOL calculation of high ametropis [J].
Haigis, W. .
OPHTHALMOLOGE, 2008, 105 (11) :999-1004