Ablation for atrial fibrillation during mitral valve surgery: 1-year results through continuous subcutaneous monitoring

被引:11
作者
Bogachev-Prokophiev, Alexandr [1 ]
Zheleznev, Sergey [1 ]
Romanov, Alexander [2 ]
Pokushalov, Evgeny [2 ]
Pivkin, Alexey [1 ]
Corbucci, Giorgio [3 ]
Karaskov, Alexander [1 ]
机构
[1] State Res Inst Circulat Pathol, Dept Heart Valves Surg, Novosibirsk, Russia
[2] State Res Inst Circulat Pathol, Dept Arrhythmia & Electrophysiol Lab, Novosibirsk, Russia
[3] Medtron BRC, Maastricht, Netherlands
关键词
Atrial fibrillation; Mitral valve surgery; Continuous subcutaneous monitoring; Radiofrequency ablation; FOLLOW-UP; MAZE-III; RADIOFREQUENCY; EXPERIENCE; THERAPY; SUCCESS;
D O I
10.1093/icvts/ivs053
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Continuous monitoring of cardiac rhythm may play an important role in measuring the true symptomatic/asymptomatic atrial fibrillation (AF) burden and improve the management of anti-arrhythmic and anti-thrombotic therapies. Forty-seven patients with mitral valve disease and longstanding persistent AF (LSPAF) underwent a left atrial maze procedure with bipolar radiofrequency and valve surgery. The follow-up data recorded by an implanted loop recorder were analysed after 3, 6 and 12 months. On discharge, 40 (85.1%) patients were in stable sinus rhythm, as documented by in-office electrocardiography (ECG), 4 (8.5%) were in pacemaker rhythm and 3 (6.4%) were in AF. One (2.1%) patient died after 7 months. On 12-month follow-up examination, 30 (65.2%) patients had an AF burden <0.5% and were classified as responders. Three (6.5%) of the 16 non-responders had atrial flutter and 13 (27.7%) had documented AF recurrences with an AF burden >0.5%. Two (4.3%) patients with AF recurrences were completely asymptomatic. Among the symptomatic events stored by the patients, only 27.6% was confirmed as genuine AF recurrences according to the concomitant ECG recorded by the implanted loop recorder. A concomitant bipolar maze procedure during mitral valve surgery is effective in treating AF, as proved by detailed 1-year continuous monitoring.
引用
收藏
页码:37 / 41
页数:5
相关论文
共 12 条
[1]   The Cox-Maze III Procedure Success Rate: Comparison by Electrocardiogram, 24-Hour Holter Monitoring and Long-Term Monitoring [J].
Ad, Niv ;
Henry, Linda ;
Hunt, Sharon ;
Barnett, Scott ;
Stone, Lori .
ANNALS OF THORACIC SURGERY, 2009, 88 (01) :101-105
[2]   Complete left atrial ablation with bipolar radiofrequency [J].
Benussi, Stefano ;
Nascimbene, Simona ;
Galanti, Andrea ;
Fumero, Andrea ;
Dorigo, Enrica ;
Zerbi, Valerio ;
Cioni, Micaela ;
Alfieri, Ottavio .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2008, 33 (04) :590-595
[3]  
Bonow RO, 2008, CIRCULATION, V118, pe523, DOI DOI 10.1161/CIRCULATI0NAHA.108.190748
[4]   HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: Recommendations for personnel, policy, procedures and follow-up [J].
Calkins, Hugh ;
Brugada, Josep ;
Packer, Douglas L. ;
Cappato, Riccardo ;
Chen, Shih-Ann ;
Crijns, Harry J. G. ;
Damiano, Ralph J., Jr. ;
Davies, D. Wyn ;
Haines, David E. ;
Haissaguerre, Michel ;
Iesaka, Yoshito ;
Jackman, Warren ;
Jais, Pierre ;
Kottkamp, Hans ;
Kuck, Karl Heinz ;
Lindsay, Bruce D. ;
Marchlinski, Francis E. ;
McCarthy, Patrick M. ;
Mont, J. Lluis ;
Morady, Fred ;
Nademanee, Koontawee ;
Natale, Andrea ;
Pappone, Carlo ;
Prystowsky, Eric ;
Raviele, Antonio ;
Ruskin, Jeremy N. ;
Shemin, Richard J. .
HEART RHYTHM, 2007, 4 (06) :816-861
[5]  
Chaiyaroj Suchart, 2008, Asian Cardiovasc Thorac Ann, V16, P292
[6]   Comparison of standard Maze III and radiofrequency Maze operations for treatment of atrial fibrillation [J].
Doty, John R. ;
Doty, Donald B. ;
Jones, Kent W. ;
Flores, Jean H. ;
Mensah, Marlene ;
Reid, Bruce B. ;
Clayson, Stephen E. ;
Snow, Greg ;
Righter, Emily ;
Millar, Roger C. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2007, 133 (04) :1037-1044
[7]   Twenty-Four-Hour Holter Monitor Follow-Up Does Not Provide Accurate Heart Rhythm Status After Surgical Atrial Fibrillation Ablation Therapy Up to 12 Months Experience With a Novel Permanently Implantable Heart Rhythm Monitor Device [J].
Hanke, Thorsten ;
Charitos, Efstratios I. ;
Stierle, Ulrich ;
Karluss, Antje ;
Kraatz, Ernst ;
Graf, Bernhard ;
Hagemann, Axel ;
Misfeld, Martin ;
Sievers, Hans H. .
CIRCULATION, 2009, 120 (11) :S177-S184
[8]   Stroke with intermittent atrial fibrillation: Incidence and predictors during aspirin therapy [J].
Hart, RG ;
Pearce, LA ;
Rothbart, RM ;
McAnulty, JH ;
Asinger, RW ;
Halperin, JL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (01) :183-187
[9]   Performance of a New Leadless Implantable Cardiac Monitor in Detecting and Quantifying Atrial Fibrillation Results of the XPECT Trial [J].
Hindricks, Gerhard ;
Pokushalov, Evgueny ;
Urban, Lubos ;
Taborsky, Milos ;
Kuck, Karl-Heinz ;
Lebedev, Dmitry ;
Rieger, Guido ;
Puererfellner, Helmut .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2010, 3 (02) :141-U44
[10]   Ablation of paroxysmal atrial fibrillation during coronary artery bypass grafting: 12 months' follow-up through implantable loop recorder [J].
Pokushalov, Evgeny ;
Romanov, Alexander ;
Cherniavsky, Alexander ;
Corbucci, Giorgio ;
Pak, Inessa ;
Kareva, Yulia ;
Karaskov, Alexander .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2011, 40 (02) :405-411