Low-dose cone-beam CT (LD-CBCT) reconstruction for image-guided radiation therapy (IGRT) by three-dimensional dual-dictionary learning

被引:10
作者
Song, Ying [1 ]
Zhang, Weikang [2 ]
Zhang, Hong [1 ]
Wang, Qiang [1 ]
Xiao, Qing [1 ]
Li, Zhibing [1 ]
Wei, Xing [1 ]
Lai, Jialu [1 ]
Wang, Xuetao [1 ]
Li, Wan [1 ]
Zhong, Quan [1 ]
Gong, Pan [1 ]
Zhong, Renming [1 ]
Zhao, Jun [2 ]
机构
[1] Sichuan Univ, West China Hosp, Dept Radiotherapy, Ctr Canc, 37 Guo Xue Alley, Chengdu 610065, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Biomed Engn, 800 Dongchuan Rd, Shanghai 610065, Peoples R China
基金
中国国家自然科学基金;
关键词
Low dose; CBCT reconstruction; Radiation therapy; Dictionary learning; COMPUTED-TOMOGRAPHY; PROJECTION;
D O I
10.1186/s13014-020-01630-3
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background To develop a low-dose cone beam CT (LD-CBCT) reconstruction method named simultaneous algebraic reconstruction technique and dual-dictionary learning (SART-DDL) joint algorithm for image guided radiation therapy (IGRT) and evaluate its imaging quality and clinical application ability. Methods In this retrospective study, 62 CBCT image sets from February 2018 to July 2018 at west china hospital were randomly collected from 42 head and neck patients (mean [standard deviation] age, 49.7 [11.4] years, 12 females and 30 males). All image sets were retrospectively reconstructed by SART-DDL (resultant D-CBCT image sets) with 18% less clinical raw projections. Reconstruction quality was evaluated by quantitative parameters compared with SART and Total Variation minimization (SART-TV) joint reconstruction algorithm with pairedttest. Five-grade subjective grading evaluations were done by two oncologists in a blind manner compared with clinically used Feldkamp-Davis-Kress algorithm CBCT images (resultant F-CBCT image sets) and the grading results were compared by paired Wilcoxon rank test. Registration results between D-CBCT and F-CBCT were compared. D-CBCT image geometry fidelity was tested. Results The mean peak signal to noise ratio of D-CBCT was 1.7 dB higher than SART-TV reconstructions (P < .001, SART-DDL vs SART-TV, 36.36 +/- 0.55 dB vs 34.68 +/- 0.28 dB). All D-CBCT images were recognized as clinically acceptable without significant difference with F-CBCT in subjective grading (P > .05). In clinical registration, the maximum translational and rotational difference was 1.8 mm and 1.7 degree respectively. The horizontal, vertical and sagittal geometry fidelity of D-CBCT were acceptable. Conclusions The image quality, geometry fidelity and clinical application ability of D-CBCT are comparable to that of the F-CBCT for head-and-neck patients with 18% less projections by SART-DDL.
引用
收藏
页数:9
相关论文
共 24 条
  • [11] Liu L.A., 2017, The international encyclopedia of intercultural communication, P1, DOI [DOI 10.1002/9781118783665.IEICC, 10.1002/9781118783665.ieicc]
  • [12] 3D Forward and Back-Projection for X-Ray CT Using Separable Footprints
    Long, Yong
    Fessler, Jeffrey A.
    Balter, James M.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (11) : 1839 - 1850
  • [13] Effects of the penalty on the penalized weighted least-squares image reconstruction for low-dose CBCT
    Ouyang, Luo
    Solberg, Timothy
    Wang, Jing
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (17) : 5535 - 5552
  • [14] Park S, 2017, IEEE T MED IMAGING, VPP, P1
  • [15] Park S, 2015, INT CONF UBIQ ROBOT, P159, DOI 10.1109/URAI.2015.7358852
  • [16] Daily patient dose from kilo-voltage cone-beam computed tomography: A comparison between XVI and OBI
    Song, W.
    Ozawa, S.
    Alani, S.
    Liu, C.
    Chvetsov, A.
    Bhandare, N.
    Palta, J.
    Li, J.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2349 - 2349
  • [17] Reconstruction of Magnetic Resonance Imaging by Three-Dimensional Dual-Dictionary Learning
    Song, Ying
    Zhu, Zhen
    Lu, Yang
    Liu, Qiegen
    Zhao, Jun
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (03) : 1285 - 1298
  • [18] Low-dose CBCT imaging for external beam radiotherapy
    Wang, J.
    Li, T.
    Xing, L.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S109 - S110
  • [19] Iterative image reconstruction for CBCT using edge-preserving prior
    Wang, Jing
    Li, Tianfang
    Xing, Lei
    [J]. MEDICAL PHYSICS, 2009, 36 (01) : 252 - 260
  • [20] Late Side Effects After Image Guided Intensity Modulated Radiation Therapy Compared to 3D-Conformal Radiation Therapy for Prostate Cancer: Results From 2 Prospective Cohorts
    Wortel, Ruud C.
    Incrocci, Luca
    Pos, Floris J.
    van der Heide, Uulke A.
    Lebesque, Joos V.
    Aluwini, Shafak
    Witte, Marnix G.
    Heemsbergen, Wilma D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 95 (02): : 680 - 689