Influence of heart rate and phase of the cardiac cycle on the occurrence of motion artifact in dual-source CT angiography of the coronary arteries

被引:56
|
作者
Achenbach, Stephan [1 ,2 ,3 ,4 ]
Manolopoulos, Michael [3 ,4 ]
Schuhbaeck, Annika [1 ,2 ]
Ropers, Dieter [3 ,4 ]
Rixe, Johannes [1 ,2 ]
Schneider, Christian [1 ,2 ]
Krombach, Gabriele A. [1 ,2 ]
Uder, Michael [3 ,4 ]
Hamm, Christian [1 ,2 ]
Daniel, Werner G. [3 ,4 ]
Lell, Michael [3 ,4 ]
机构
[1] Univ Giessen, Dept Cardiol, D-35392 Giessen, Germany
[2] Univ Giessen, Dept Radiol, D-35392 Giessen, Germany
[3] Univ Erlangen Nurnberg, Dept Radiol, Erlangen, Germany
[4] Univ Erlangen Nurnberg, Dept Cardiol, Erlangen, Germany
关键词
Coronary CT angiography; Image quality; Heart rate; Dual-source CT; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; IMAGE QUALITY; RATE-VARIABILITY; RECONSTRUCTION INTERVALS; DIAGNOSTIC-ACCURACY; RADIATION-EXPOSURE; WINDOWS;
D O I
10.1016/j.jcct.2011.11.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Coronary CT angiography allows visualization of the coronary arteries. However, motion artifact can impair delineation of the coronary artery lumen and detection of coronary artery stenoses. OBJECTIVE: We investigated the influence of heart rate and the segment of the cardiac cycle during which images are reconstructed on the occurrence of motion artifacts. METHODS: We evaluated coronary CT angiography datasets obtained by 64-slice dual-source CT in 100 consecutive patients. Data were reconstructed at 13 time instants during the cardiac cycle and evaluated for the presence of motion artifact. RESULTS: Mean heart rate was 66 +/- 14 beats/min. Overall, 98 of 100 patients had evaluable datasets. For heart rates <= 60 beats/min, optimal image quality was uniformly found during late diastole (100% of cases with evaluable image quality during a time window between 65% and 75% of the cardiac cycle). With increasing heart rates, images reconstructed during late systole more frequently provided best image quality. However, image reconstruction could not be restricted to a systolic time period. To achieve evaluable image quality in 95% of cases, data acquired between 25% and 75% of the cardiac cycle had to be available for patients with heart rates >60 beats/min. CONCLUSION: Dual-source CT provides high image quality across a wide range of heart rates. Although data acquisition may be limited to diastole for patients with heart rates <= 60 beats/min, the availability of data acquired both during systole and diastole is necessary for patients with higher heart rates. (C) 2012 Society of Cardiovascular Computed Tomography. All rights reserved.
引用
收藏
页码:91 / 98
页数:8
相关论文
共 50 条
  • [31] High-pitch coronary CT angiography with third generation dual-source CT: limits of heart rate
    Sonja Gordic
    Daniela B. Husarik
    Lotus Desbiolles
    Sebastian Leschka
    Thomas Frauenfelder
    Hatem Alkadhi
    The International Journal of Cardiovascular Imaging, 2014, 30 : 1173 - 1179
  • [32] Dual-source CT coronary angiography: prospective versus retrospective acquisition technique
    De Cecco, C. N.
    Buffa, V.
    Fedeli, S.
    Vallone, A.
    Ruopoli, R.
    Luzietti, M.
    Miele, V.
    Enrici, M. Maurizi
    Musumeci, F.
    David, V.
    RADIOLOGIA MEDICA, 2011, 116 (02): : 178 - 188
  • [33] Defining the optimal systolic phase targets using absolute delay time for reconstructions in dual-source coronary CT angiography
    Celeng, Csilla
    Vadvala, Harshna
    Puchner, Stefan
    Pursnani, Amit
    Sharma, Umesh
    Kovacs, Attila
    Maurovich-Horvat, Pal
    Hoffmann, Udo
    Ghoshhajra, Brian
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2016, 32 (01) : 91 - 100
  • [34] Low-Dose Scan Protocols in Dual-Source CT Coronary Angiography
    Li, Min
    Sun, Gang
    RADIOLOGY, 2012, 263 (03) : 937 - 938
  • [35] Strengths and limitations of coronary angiography with turbo high-pitch third-generation dual-source CT
    Ochs, M. M.
    Andre, F.
    Korosoglou, G.
    Fritz, T.
    Seitz, S.
    Bogomazov, Y.
    Schlett, C. L.
    Sokiranski, R.
    Sommer, A.
    Gueckel, F.
    Brado, M.
    Kauczor, H. -U.
    Goerich, J.
    Buss, S. J.
    CLINICAL RADIOLOGY, 2017, 72 (09) : 739 - 744
  • [36] Dual-Source versus 64-Section CT Coronary Angiography at Lower Heart Rates: Comparison of Accuracy and Radiation Dose
    Baumueller, Stephan
    Leschka, Sebastian
    Desbiolles, Lotus
    Stolzmann, Paul
    Scheffel, Hans
    Seifert, Burkhardt
    Marincek, Borut
    Alkadhi, Hatem
    RADIOLOGY, 2009, 253 (01) : 56 - 64
  • [37] Automatic selection of optimal systolic and diastolic reconstruction windows for dual-source CT coronary angiography
    Seifarth, H.
    Puesken, M.
    Wienbeck, S.
    Maintz, D.
    Fischbach, R.
    Heindel, W.
    Juergens, K. -U.
    EUROPEAN RADIOLOGY, 2009, 19 (07) : 1645 - 1652
  • [38] Dual-source CT coronary angiography: image quality and optimal reconstruction interval
    Bastarrika, G.
    Arraiza, M.
    Arias, J.
    Broncano, J.
    Zudaire, B.
    Pueyo, J. C.
    del Barrio, Y. L. Garcia
    RADIOLOGIA, 2009, 51 (04): : 376 - 384
  • [39] Heart Rate-Dependent Degree of Motion Artifacts in Coronary CT Angiography Acquired by a Novel Purpose-Built Cardiac CT Scanner
    Vecsey-Nagy, Milan
    Jermendy, Adam Levente
    Kolossvary, Marton
    Vattay, Borbala
    Boussoussou, Melinda
    Suhai, Ferenc Imre
    Panajotu, Alexisz
    Csore, Judit
    Borzsak, Sarolta
    Fontanini, Daniele Mariastefano
    Csobay-Novak, Csaba
    Merkely, Bela
    Maurovich-Horvat, Pal
    Szilveszter, Balint
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (15)
  • [40] Prospectively ECG-triggered sequential dual-source coronary CT angiography in patients with atrial fibrillation: comparison with retrospectively ECG-gated helical CT
    Xu, Lei
    Yang, Lin
    Zhang, Zhaoqi
    Wang, Yining
    Jin, Zhengyu
    Zhang, Longjiang
    Lu, Guangming
    EUROPEAN RADIOLOGY, 2013, 23 (07) : 1822 - 1828