Influence of heart rate and phase of the cardiac cycle on the occurrence of motion artifact in dual-source CT angiography of the coronary arteries

被引:56
|
作者
Achenbach, Stephan [1 ,2 ,3 ,4 ]
Manolopoulos, Michael [3 ,4 ]
Schuhbaeck, Annika [1 ,2 ]
Ropers, Dieter [3 ,4 ]
Rixe, Johannes [1 ,2 ]
Schneider, Christian [1 ,2 ]
Krombach, Gabriele A. [1 ,2 ]
Uder, Michael [3 ,4 ]
Hamm, Christian [1 ,2 ]
Daniel, Werner G. [3 ,4 ]
Lell, Michael [3 ,4 ]
机构
[1] Univ Giessen, Dept Cardiol, D-35392 Giessen, Germany
[2] Univ Giessen, Dept Radiol, D-35392 Giessen, Germany
[3] Univ Erlangen Nurnberg, Dept Radiol, Erlangen, Germany
[4] Univ Erlangen Nurnberg, Dept Cardiol, Erlangen, Germany
关键词
Coronary CT angiography; Image quality; Heart rate; Dual-source CT; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; IMAGE QUALITY; RATE-VARIABILITY; RECONSTRUCTION INTERVALS; DIAGNOSTIC-ACCURACY; RADIATION-EXPOSURE; WINDOWS;
D O I
10.1016/j.jcct.2011.11.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Coronary CT angiography allows visualization of the coronary arteries. However, motion artifact can impair delineation of the coronary artery lumen and detection of coronary artery stenoses. OBJECTIVE: We investigated the influence of heart rate and the segment of the cardiac cycle during which images are reconstructed on the occurrence of motion artifacts. METHODS: We evaluated coronary CT angiography datasets obtained by 64-slice dual-source CT in 100 consecutive patients. Data were reconstructed at 13 time instants during the cardiac cycle and evaluated for the presence of motion artifact. RESULTS: Mean heart rate was 66 +/- 14 beats/min. Overall, 98 of 100 patients had evaluable datasets. For heart rates <= 60 beats/min, optimal image quality was uniformly found during late diastole (100% of cases with evaluable image quality during a time window between 65% and 75% of the cardiac cycle). With increasing heart rates, images reconstructed during late systole more frequently provided best image quality. However, image reconstruction could not be restricted to a systolic time period. To achieve evaluable image quality in 95% of cases, data acquired between 25% and 75% of the cardiac cycle had to be available for patients with heart rates >60 beats/min. CONCLUSION: Dual-source CT provides high image quality across a wide range of heart rates. Although data acquisition may be limited to diastole for patients with heart rates <= 60 beats/min, the availability of data acquired both during systole and diastole is necessary for patients with higher heart rates. (C) 2012 Society of Cardiovascular Computed Tomography. All rights reserved.
引用
收藏
页码:91 / 98
页数:8
相关论文
共 50 条
  • [21] Diagnostic accuracy of dual-source CT coronary angiography: The effect of average heart rate, heart rate variability, and calcium score in a clinical perspective
    Zhang, Long-Jiang
    Wu, Sheng-Yong
    Wang, Jing
    Lu, Ying
    Zhang, Zhuo-Li
    Jiang, Shi-Sen
    Zhou, Chang-Sheng
    Lu, Guang-Ming
    ACTA RADIOLOGICA, 2010, 51 (07) : 727 - 740
  • [22] Diagnostic Quality of Dual-Source Coronary CT Examinations Performed Without Heart Rate Control: Importance of Obesity and Heart Rate on Image Quality
    Zimmerman, Stefan L.
    Kral, Brian G.
    Fishman, Elliot K.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2014, 38 (06) : 949 - 955
  • [23] Diagnostic accuracy of dual-source CT coronary angiography with prospective ECG-triggering on different heart rate patients
    Sun, Ming-li
    Lu, Bin
    Wu, Run-ze
    Johnson, Laura
    Han, Lei
    Liu, Gang
    Yu, Fang-Fang
    Hou, Zhi-hui
    Gao, Yang
    Wang, Hong-yu
    Jiang, Shiliang
    Yang, Yue-jin
    Qiao, Shu-bin
    EUROPEAN RADIOLOGY, 2011, 21 (08) : 1635 - 1642
  • [24] Dual-source computed tomography coronary angiography in patients with high heart rate
    Tatsuhiro Fujimura
    Toshiro Miura
    Tomoko Nao
    Masayuki Yoshimura
    Yoshiteru Nakashima
    Munemasa Okada
    Takayuki Okamura
    Jutaro Yamada
    Chikage Ohshita
    Yasuaki Wada
    Naofumi Matsunaga
    Masunori Matsuzaki
    Masafumi Yano
    Heart and Vessels, 2014, 29 : 443 - 448
  • [25] Myocardial Bridging of the Left Anterior Descending Coronary Artery: Depiction Rate and Morphologic Features by Dual-Source CT Coronary Angiography
    Hwang, Jin Ho
    Ko, Sung Min
    Roh, Hong Gee
    Song, Meong Gun
    Shin, Je Kyoun
    Chee, Hyun Kun
    Kim, Joon Suk
    KOREAN JOURNAL OF RADIOLOGY, 2010, 11 (05) : 514 - 521
  • [26] Impact of heart rate on coronary computed tomographic angiography interpretability with a third-generation dual-source scanner
    Miller, Robert J. H.
    Eisenberg, Evann
    Friedman, John
    Cheng, Victor
    Hayes, Sean
    Tamarappoo, Balaji
    Thomson, Louise
    Berman, Daniel S.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2019, 295 : 42 - 47
  • [27] Diagnostic performance of dual-source CT coronary angiography with and without heart rate control: Systematic review and meta-analysis
    Li, M.
    Zhang, G. -M.
    Zhao, J. -S.
    Jiang, Z. -W.
    Peng, Z. -H.
    Jin, Z. -T.
    Sun, G.
    CLINICAL RADIOLOGY, 2014, 69 (02) : 163 - 171
  • [28] Limits of the possible: diagnostic image quality in coronary angiography with third-generation dual-source CT
    Ochs, Marco M.
    Siepen, Fabian Aus Dem
    Fritz, Thomas
    Andre, Florian
    Gitsioudis, Gitsios
    Korosoglou, Grigorios
    Seitz, Sebastian
    Bogomazov, Yuriy
    Schlett, Christopher L.
    Sokiranski, Roman
    Sommer, Andre
    Gueckel, Friedemann
    Brado, Matthias
    Kauczor, Hans-Ulrich
    Goerich, Johannes
    Friedrich, Matthias G. W.
    Katus, Hugo A.
    Buss, Sebastian J.
    CLINICAL RESEARCH IN CARDIOLOGY, 2017, 106 (07) : 485 - 492
  • [29] Evaluation of coronary stent patency and in-stent restenosis with dual-source CT coronary angiography without heart rate control
    Oncel, Dilek
    Oncel, Guray
    Tastan, Ahmet
    Tamci, Batuhan
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (01) : 56 - 63
  • [30] Effect of Heart Rate and Coronary Calcification on the Diagnostic Accuracy of the Dual-Source CT Coronary Angiography in Patients with Suspected Coronary Artery Disease
    Meng, Lingdong
    Cui, Lianqun
    Cheng, Yuntao
    Wu, Xiaoyan
    Tang, Yuansheng
    Wang, Yong
    Xu, Fayun
    KOREAN JOURNAL OF RADIOLOGY, 2009, 10 (04) : 347 - 354