A DC Offset Current Compensation Strategy in Transformerless Grid-Connected Power Converters

被引:65
作者
Buticchi, Giampaolo [1 ]
Lorenzani, Emilio [2 ]
Franceschini, Giovanni [1 ]
机构
[1] Univ Parma, Dipartimento Ingn Informaz, I-43124 Parma, Italy
[2] Univ Modena & Reggio Emilia, Dipartimento Sci & Metodi Ingn, I-42122 Reggio Emilia, Italy
关键词
Photovoltaic power systems; power generation control; power quality; pulsewidth-modulated power converters;
D O I
10.1109/TPWRD.2011.2167160
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A line frequency transformer is usually employed in grid-connected power converters, from both renewable and traditional energy sources, in order to suppress the DC current component and the ground leakage current. Solutions employing a high frequency transformer or employing no transformer at all have recently been investigated in order to reduce size, weight and cost. As a consequence, unless a suitable remedy is adopted, a DC current component exceeding the limits enforced by international standards may be injected into the grid. This paper proposes a simple and cheap solution to reduce the DC current component injected into the grid in the case of a full-bridge, single-phase, transformerless converter. The proposed strategy is intrinsically insensitive to offset measurement errors and can be utilized as a robust and dynamic offset compensator for the current transducer. The simulation results have confirmed the theoretical behavior of the proposed solution, while the experimental ones, performed for different values of output power and for different current control architectures, have shown its effectiveness.
引用
收藏
页码:2743 / 2751
页数:9
相关论文
共 19 条
[1]  
Ahfock T. L., 2006, AUPEC MELB AUSTR DEC
[2]  
[Anonymous], 15472003 IEEE
[3]  
[Anonymous], 2004, LEM PUBL
[4]   Auto-calibrating dc link current sensing technique for transformerless, grid connected, H-bridge inverter systems [J].
Armstrong, Matthew ;
Atkinson, David. J. ;
Johnson, C. Mark ;
Abeyasekera, Tusitha. D. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2006, 21 (05) :1385-1393
[5]   Approach to low-cost prevention of DC injection in transformerless grid connected inverters [J].
Blewitt, W. M. ;
Atkinson, D. J. ;
Kelly, J. ;
Lakin, R. A. .
IET POWER ELECTRONICS, 2010, 3 (01) :111-119
[6]   Direct current offset controller for transformerless single-phase photovoltaic grid-connected inverters [J].
Bowtell, L. ;
Ahfock, A. .
IET RENEWABLE POWER GENERATION, 2010, 4 (05) :428-437
[7]  
Enders W., 2001, P 17 EUR PHOT SOL EN, P1
[8]  
Franceschetti G., 2010, 2010 IEEE International Symposium Antennas and Propagation and CNC-USNC/URSI Radio Science Meeting, DOI 10.1109/APS.2010.5562082
[9]  
Gertmar L., 2005, 2005 IEEE 11th European Conference on Power Electronics and Applications
[10]  
*IEA PVPS, 1998, V201 IEA PVPS