Ultrasound-assisted cloud point extraction for speciation and indirect spectrophotometric determination of chromium(III) and (VI) in water samples

被引:40
作者
Hashemi, Mandi [1 ]
Daryanavard, Seyed Mosayeb [1 ,2 ]
机构
[1] Bu Ali Sina Univ, Dept Analyt Chem, Fac Chem, Hamadan, Iran
[2] Univ Hormozgan, Fac Sci, Bandar Abbas, Iran
关键词
Chromium; Ultrasound-assisted cloud point extraction; Speciation; Spectrophotometry; Electroplating wastewater; ATOMIC-ABSORPTION-SPECTROMETRY; ICP-OES; CR-III; PRECONCENTRATION; SEPARATION; MEDIA; ION;
D O I
10.1016/j.saa.2012.02.073
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Ultrasound-assisted cloud point extraction (UACPE) procedure was developed for speciation and indirect spectrophotometric determination of chromium(III) and (VI) in environmental water samples. The method is based on the reduction of Cr(VI) by iodide in acidic media and subsequently formation of I-3- anion. The I-3- formed can further react with cetyltrimethylammonium bromide (CTAB) and induce its clouding due to formation of an ion-association complex. The formed complex was separated from solution and dissolved in ethanol for spectrophotometric measurement. Cerium(IV) ammonium sulphate was chosen as an oxidizing reagent for pre-oxidation step of Cr(III) to Cr(VI) species before the addition of iodide to the system, up to chromium in trivalent can be determined by the procedure. Experimental parameters for both spectrophotometric reaction and extraction procedure have been optimized. Under optimized conditions Cr(VI) can be determined in the range 20-400 ng mL(-1) (R-2 = 0.999). Detection limit, preconcentration factor and relative standard deviation were 12 ng mL(-1), 20.0 and 2.2% (n = 5), respectively with 10mL sample volumes. The proposed method has been successfully applied for determination of chromium(V) in spiked water, synthetic seawater and electroplating wastewater samples with average recoveries of 100.1, 99.4 and 99.1%, respectively. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:189 / 193
页数:5
相关论文
共 29 条
[1]   Preconcentration and speciation of chromium in waters using solid-phase extraction and atomic absorption spectrometry [J].
Adriá-Cerezo, DM ;
Llobat-Estellés, M ;
Maurí-Aucejo, AR .
TALANTA, 2000, 51 (03) :531-536
[2]  
Arab-zavar M.H., 2000, TALANTA, V52, P1007
[3]  
Balasubramanian N, 1996, J AOAC INT, V79, P989
[4]   FLOW-INJECTION EXTRACTION SPECTROPHOTOMETRIC DETERMINATION OF CHROMIUM(VI) WITH THE BENZYLTRIBUTYLAMMONIUM CATION [J].
BARAKAT, SA ;
BURNS, DT ;
HARRIOTT, M .
ANALYTICA CHIMICA ACTA, 1993, 272 (01) :135-138
[5]   Ultrasound in analytical chemistry [J].
Capote, F. Priego ;
Luque de Castro, M. D. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (01) :249-257
[6]   Sensitized spectrophotometric determination of Cr(III) ion for speciation of chromium ion in surfactant media using α-benzoin oxime [J].
Ghaedi, M ;
Asadpour, E ;
Vafaie, A .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2006, 63 (01) :182-188
[7]   The simple and rapid spectrophotometric determination of trace chromium(VI) after preconcentration as its colored complex on chitin [J].
Hoshi, S ;
Konuma, K ;
Sugawara, K ;
Uto, M ;
Akatsuka, K .
TALANTA, 1998, 47 (03) :659-663
[8]   AN INDIRECT METHOD FOR THE DETERMINATION OF CHROMIUM SPECIES IN WATER SAMPLES BY SEQUENTIAL INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY [J].
KORN, M ;
KORN, MGA ;
REIS, BF ;
DEOLIVEIRA, E .
TALANTA, 1994, 41 (12) :2043-2047
[9]   Speciation of chromium in water samples by cloud point extraction combined with low temperature electrothermal vaporization ICP-OES [J].
Li, YJ ;
Hu, B ;
Jiang, ZC ;
Wu, YW .
ANALYTICAL LETTERS, 2006, 39 (04) :809-822
[10]  
Liang P, 2005, ATOM SPECTROSC, V26, P89