Flow amperometric detection of indigo for enzyme-linked immunosorbent assays with use of screen-printed electrodes

被引:12
作者
Alvarez, MJB [1 ]
Abedul, MTF [1 ]
García, AC [1 ]
机构
[1] Univ Oviedo, Dept Quim Fis & Analit, E-33006 Oviedo, Asturias, Spain
关键词
flow electrochemical enzyme immunoassay screen-printed electrodes; ELISA; pneumolysin; 3-indoxyl phosphate; alkaline phosphatase;
D O I
10.1016/S0003-2670(02)00310-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and automated methodology for a sensitive electrochemical detection of enzyme immunoassays that employ alkaline phosphatase (AP) as label has been developed. A flow injection system with programmable pump, valve and cell functions, amperometric detection of indigo and screen-printed electrodes (SPEs) are responsible for the advantages of this methodology. Amperometric detection at a low potential of indigo, the product of the enzymatic hydrolysis of the substrate 3-indoxyl phosphate (IP), is combined with a flow injection system. This incorporates in the flow cell a disposable screen-printed board provided with a graphite working electrode. No electrode pretreatment is necessary to obtain reproducible signals. The system was applied to the determination by an enzyme-linked immunosorbent assays (ELISA) of pneumolysin (PLY), a toxin related to respiratory infections. Linear calibration curves for low and high concentration ranges were obtained. These were also performed in a proteic matrix and linearity was also obtained. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:31 / 37
页数:7
相关论文
共 22 条
  • [1] Anderson DJ, 1997, ANAL CHEM, V69, pR165
  • [2] AVIDIN-BIOTIN BASED ELECTROCHEMICAL IMMUNOASSAY FOR THYROTROPIN
    ATHEY, D
    BALL, M
    MCNEIL, CJ
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 1993, 30 : 570 - 577
  • [3] Automated amplified flow immunoassay for cocaine
    Bauer, CG
    Eremenko, AV
    Kühn, A
    Kürzinger, K
    Makower, A
    Scheller, FW
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (21) : 4624 - 4630
  • [4] Bengoechea Alvarez M. Jose, 2001, Analytica Chimica Acta, V442, P55
  • [5] Can affinity sensors be used to detect food contaminants?
    Bilitewski, U
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (21) : 692A - 701A
  • [6] A specific and ultrasensitive chemiluminescent sandwich ELISA test for the detection and quantitation of pneumolysin
    Cima-Cabal, MD
    Méndez, FJ
    Vázquez, F
    Garcia-Suárez, MD
    de los Toyos, JR
    [J]. JOURNAL OF IMMUNOASSAY & IMMUNOCHEMISTRY, 2001, 22 (02) : 99 - 112
  • [7] DIAZGARCIA M, IN PRESS ELECTROANAL
  • [8] Fernandez Bobes Cecilia, 2001, Electroanalysis, V13, P559
  • [9] Competitive enzyme immunosensor developed on a renewable carbon paste electrode support
    Fernández-Sánchez, C
    Costa-García, A
    [J]. ANALYTICA CHIMICA ACTA, 1999, 402 (1-2) : 119 - 127
  • [10] AC voltammetric carbon paste-based enzyme immunosensors
    Fernández-Sánchez, C
    González-García, MB
    Costa-García, A
    [J]. BIOSENSORS & BIOELECTRONICS, 2000, 14 (12) : 917 - 924