Elemental assessment of dried and ground samples of leeches via portable X-ray fluorescence

被引:0
作者
Zhou, Shubin [1 ]
Cheng, Qiuming [1 ]
Weindorf, David C. [2 ]
Yuan, Zhaoxian [3 ]
Yang, Biying [1 ]
Sun, Qun [4 ]
Zhang, Zhenjie [1 ]
Yang, Jie [1 ]
Zhao, Molei [1 ]
机构
[1] China Univ Geosci, State Key Lab Geol Proc & Mineral Resources, Beijing 100083, Peoples R China
[2] Cent Michigan Univ, Dept Earth & Atmospher Sci, Mt Pleast, MI 48859 USA
[3] Hebei Geo Univ, Inst Resource & Environm Engn, Shijiazhuang 050031, Peoples R China
[4] Hebei Univ Technol, Sch Chem Engn, Tianjin 300401, Peoples R China
基金
中国国家自然科学基金;
关键词
TRADITIONAL CHINESE MEDICINE; TRACE-ELEMENTS; IN-SITU; CHARACTERIZING SOILS; HEAVY-METALS; XRF ANALYSIS; SPECTROMETRY; CONTAMINATION; SEDIMENTS; NAIL;
D O I
10.1039/d0ja00328j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Determination of elemental concentrations in animal tissues is critically important due to the extensive use of animal tissues in food and medicine. Traditionally, elemental analysis has mostly relied on laboratory-based methods, such as inductively coupled plasma atomic emission spectrometry (ICP-AES) and inductively coupled plasma mass spectrometry (ICP-MS). Portable X-ray fluorescence (XRF) spectrometry, which has been widely applied in soil and rock analysis, has rarely been used to quantify elements in animal tissues. In this pilot study, the effectiveness of using pXRF to determine elemental concentrations in leeches was demonstrated. The effects of the moisture content and compaction (density) on pXRF readings were experimentally quantified. The penetration depth of X-rays in leech samples is generally <15 mm. For leech samples with different thicknesses (thicknesses ranging from 2.5 mm to 15 mm), measured pXRF elemental concentrations were found to decrease with increasing sample thickness in a power function, the square of the correlation coefficient (R-2) of which was 0.96 and 0.89 for Zn and Fe, respectively. Therefore, the thickness correction for intermediate sample thickness is possible in future analysis, enabling a more accurate analysis for samples with insufficient sample mass. The detection limits determined for As and Cu in dried and ground leech samples with a thickness of similar to 15 mm were similar to 5 and similar to 20 mg kg(-1), respectively, which were equal to/lower than the regulatory limits for both food and medicine. The pXRF measured concentrations of S, K, Fe, Cu, Zn, and As were highly correlated with ICP results (R-2 >= 0.92), with the exception of Ca (R-2 = 0.81). Simple linear regression models were employed to predict the ICP-based elemental composition of 15 leech samples using pXRF elemental data as inputs; the validation results were quite good for all the studied elements (R-2 >= 0.92). Thus, pXRF shows great potential for safety control of elemental concentrations in food and medicine.
引用
收藏
页码:2573 / 2581
页数:9
相关论文
共 50 条
  • [41] Organic matter removal on oxide determination in Oxisols via portable X-ray fluorescence
    Costa, Yasmmin Tadeu
    Ribeiro, Bruno Teixeira
    Curi, Nilton
    de Oliveira, Geraldo Cesar
    Guimaraes Guilherme, Luiz Roberto
    COMMUNICATIONS IN SOIL SCIENCE AND PLANT ANALYSIS, 2019, 50 (06) : 673 - 681
  • [42] Forensic identification of pharmaceuticals via portable X-ray fluorescence and diffuse reflectance spectroscopy
    Shutic, Sarah
    Chakraborty, Somsubhra
    Li, Bin
    Weindorf, David C.
    Sperry, Kathy
    Casadonte, Dominick
    FORENSIC SCIENCE INTERNATIONAL, 2017, 279 : 22 - 32
  • [43] Compost Cation Exchange Capacity via Portable X-Ray Fluorescence (PXRF) Spectrometry
    Li, Bin
    Chakraborty, Somsubhra
    Sosa, Maria Fernanda Godoy
    Kusi, Nana Yaw O.
    Weindorf, David C.
    COMPOST SCIENCE & UTILIZATION, 2018, 26 (04) : 271 - 278
  • [44] Assessment of copper bioaccumulation in Euglena gracilis by X-Ray fluorescence technique
    Cervantes-Garcia, David
    Rubalcaba-Sil, Jose Luis
    Gonzalez-Mendoza, Daniel
    Aviles-Marin, Monica
    LATIN AMERICAN JOURNAL OF AQUATIC RESEARCH, 2014, 42 (03): : 662 - 665
  • [45] Plant elemental composition and portable X-ray fluorescence (pXRF) spectroscopy: quantification under different analytical parameters
    Towett, Erick K.
    Shepherd, Keith D.
    Drake, B. Lee
    X-RAY SPECTROMETRY, 2016, 45 (02) : 117 - 124
  • [46] Elemental Composition in Female Dry Femora Using Portable X-Ray Fluorescence (pXRF): Association with Age and Osteoporosis
    Zdral, Sofia
    Monge Calleja, Alvaro M.
    Catarino, Lidia
    Curate, Francisco
    Santos, Ana Luisa
    CALCIFIED TISSUE INTERNATIONAL, 2021, 109 (02) : 231 - 240
  • [47] X-ray Diffraction and Elemental Analysis of Medical and Environmental Samples
    Bielecka, K.
    Kurtek, W.
    Banas, D.
    Kubala-Kukus, A.
    Braziewicz, J.
    Majewska, U.
    Pajek, M.
    Wudarczyk-Mocko, J.
    Stabrawa, I.
    ACTA PHYSICA POLONICA A, 2014, 125 (04) : 911 - 918
  • [48] Practical Considerations in Trace Element Analysis of Bone by Portable X-ray Fluorescence
    Byrnes, Jennifer F.
    Bush, Peter J.
    JOURNAL OF FORENSIC SCIENCES, 2016, 61 (04) : 1041 - 1045
  • [49] Comparison of portable X-ray fluorescence spectrometry and laboratory-based methods to assess the soil elemental composition: Applications for wetland soils
    Borges, Camila Silva
    Weindorf, David C.
    Nascimento, Diogo Costa
    Curi, Nilton
    Guimaraes Guilherme, Luiz Roberto
    Carvalho, Geila Santos
    Ribeiro, Bruno Teixeira
    ENVIRONMENTAL TECHNOLOGY & INNOVATION, 2020, 19
  • [50] Calibration of portable X-ray fluorescence equipment for the geochemical analysis of carbonate matrices
    Arenas-Islas, Diana
    Angel Huerta-Diaz, Miguel
    Orion Norzagaray-Lopez, Carlos
    Gabriela Mejia-Pina, Karla
    Alberto Valdivieso-Ojeda, Jacob
    Luis Otero, Xose
    Arcega-Cabrera, Flor
    SEDIMENTARY GEOLOGY, 2019, 391