Comparative experimental analysis on the in-plane shear performance of brick masonry walls strengthened with different fiber reinforced materials

被引:39
作者
Cheng, Shuaian [1 ]
Yin, Shiping [1 ,2 ]
Jing, Lei [1 ]
机构
[1] China Univ Min & Technol, Sch Mech & Civil Engn, Jiangsu Key Lab Environm Impact & Struct Safety E, Xuzhou 221116, Jiangsu, Peoples R China
[2] China Univ Min & Technol, Sch Mech & Civil Engn, State Key Lab Geomech & Deep Underground Engn, Xuzhou 221116, Jiangsu, Peoples R China
关键词
Unreinforced masonry wall; Strengthening; FRP (fiber-reinforced polymer); ECC (engineered cementitious composite); TRC (textile-reinforced concrete); In-plane shear performance; URM WALLS; BEHAVIOR; FRP; COMPOSITES; CAPACITY; CLAY;
D O I
10.1016/j.conbuildmat.2020.120387
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Masonry structures are very vulnerable during earthquakes, and masonry walls, as the main load-bearing members, are susceptible to in-plane shear generated by earthquakes. In order to compare the shear performance of masonry walls strengthened with different fiber-reinforced materials, in-plane shear tests were carried out on 20 masonry wall specimens. Mortar-, fiber-reinforced polymer (FRP)-, engineered cementitious composite (ECC)-, textile-reinforced concrete (TRC)- and bed joint-strengthening were mainly considered. The failure modes, shear strength, pseudo-ductility and energy dissipation of different strengthening methods were analyzed and discussed. Test results showed that unreinforced, mortar- and bed joint-strengthened masonry walls had different degrees of brittleness when they were damaged, and the FRP-, ECC-, and TRC-strengthening could improve this brittleness failure phenomenon. Under the experimental conditions in this study, the effects of ECC and TRC in shear strength enhancement were comparable comparative, and the shear strength of FRP was slightly smaller than the other two materials. The TRC-strengthened specimens had the best pseudo-ductility and energy dissipation, and the FRP-strengthened specimens were the poorest ones. The ECC-strengthened specimens were somewhere in between. Based on the collected test results of the popular TRC-strengthened masonry walls, the calculated and designed values were analyzed using the design method suggested by ACI 549.4R. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:13
相关论文
共 36 条
[1]   Assessment of overlay masonry strengthening system under in-plane monotonic and cyclic loading using the diagonal tensile test [J].
Almeida, Joao A. P. P. ;
Pereira, Eduardo B. ;
Barros, Joaquim A. O. .
CONSTRUCTION AND BUILDING MATERIALS, 2015, 94 :851-865
[2]  
[Anonymous], 2011, GB/T 50129-2011
[3]  
[Anonymous], 2010, Standard Test Method for Diagonal Tension (Shear) in Masonry Assemblages
[4]  
[Anonymous], 2013, 4594R13 ACI
[5]  
[Anonymous], 2009, JGJ/T 70-2009
[6]  
[Anonymous], 2011, 507022011 GB
[7]   Shear strengthening of un-reinforced concrete masonry walls with fabric-reinforced-cementitious-matrix [J].
Babaeidarabad, Saman ;
Arboleda, Diana ;
Loreto, Giovanni ;
Nanni, Antonio .
CONSTRUCTION AND BUILDING MATERIALS, 2014, 65 :243-253
[8]   URM Walls Strengthened with Fabric-Reinforced Cementitious Matrix Composite Subjected to Diagonal Compression [J].
Babaeidarabad, Saman ;
De Caso, Francisco ;
Nanni, Antonio .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2014, 18 (02)
[9]   Shear behaviour of masonry walls strengthened by external bonded FRP and TRC [J].
Bui, Thi-Loan ;
Larbi, A. Si ;
Reboul, N. ;
Ferrier, E. .
COMPOSITE STRUCTURES, 2015, 132 :923-932
[10]   Advanced Strategies and Materials for Reinforcing Normal and Disturbed Regions in Brick Masonry Columns [J].
Campione, Giuseppe ;
Cavaleri, Liborio ;
Papia, Maurizio .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2016, 20 (04)