A comparison of the Seeing Optical Stylet and the gum elastic bougie in simulated difficult tracheal intubation: a manikin study

被引:25
作者
Evans, A
Morris, S
Petterson, J
Hall, JE
机构
[1] Univ Wales Hosp, Cardiff CF14 4XN, S Glam, Wales
[2] Cardiff Univ, Wales Coll Med, Cardiff, S Glam, Wales
关键词
D O I
10.1111/j.1365-2044.2006.04539.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Management of the difficult airway is one of the major challenges that anaesthetists face. The flexible fibreoptic scope is widely available but its use requires a level of skill, training and continued practice that is not universally found in all anaesthetists, particularly trainees. The Seeing Optical Stylet is a new, semirigid fibreoptic stylet 'scope. We compared the Seeing Optical Stylet with a gum elastic bougie in a simulated Cormack and Lehane Grade 3 laryngoscopy in a manikin. Forty-four anaesthetists were timed while intubating the manikin's trachea with both devices. The mean (SD) time taken with the Seeing Optical Stylet was 20.8 (9.3) s and with the bougie 30 (19.8) s (p = 0.001). Oesophageal intubation occurred six times with the bougie but did not occur with the Seeing Optical Stylet (p = 0.011). We conclude that the Seeing Optical Stylet may be superior to the bougie in difficult tracheal intubation. We feel that the results of this manikin trial are sufficiently encouraging to proceed to a clinical trial in patients.
引用
收藏
页码:478 / 481
页数:4
相关论文
共 19 条
  • [1] The Seeing Stylet:: a new device for tracheal intubation
    Agrò, F
    Cataldo, R
    Carassiti, M
    Costa, F
    [J]. RESUSCITATION, 2000, 44 (03) : 177 - 180
  • [2] A comparison of the intubating laryngeal mask airway and the Bonfils intubation fibrescope in patients with predicted difficult airways
    Bein, B
    Worthmann, F
    Scholz, J
    Brinkmann, F
    Tonner, PH
    Steinfath, M
    Dörges, V
    [J]. ANAESTHESIA, 2004, 59 (07) : 668 - 674
  • [3] A new practical classification of laryngeal view
    Cook, TM
    [J]. ANAESTHESIA, 2000, 55 (03) : 274 - 279
  • [4] DIFFICULT TRACHEAL INTUBATION IN OBSTETRICS
    CORMACK, RS
    LEHANE, J
    [J]. ANAESTHESIA, 1984, 39 (11) : 1105 - 1111
  • [5] RAPIDITY AND ACCURACY OF TRACHEAL INTUBATION IN A MANNEQUIN - COMPARISON OF THE FIBEROPTIC WITH THE BULLARD LARYNGOSCOPE
    DYSON, A
    HARRIS, J
    BHATIA, K
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1990, 65 (02) : 268 - 270
  • [6] Difficult airway management practice patterns among anesthesiologists practicing in the United States: Have we made any progress?
    Ezri, T
    Szmuk, P
    Warters, RD
    Katz, J
    Hagberg, CA
    [J]. JOURNAL OF CLINICAL ANESTHESIA, 2003, 15 (06) : 418 - 422
  • [7] Clinical trial of a new device for fiberoptic orotracheal intubation (Augustine Scope(TM))
    Krafft, P
    Krenn, CG
    Fitzgerald, RD
    Pernerstorfer, T
    Fridrich, P
    Weinstabl, C
    [J]. ANESTHESIA AND ANALGESIA, 1997, 84 (03) : 606 - 610
  • [8] Survey of the use of the gum elastic bougie in clinical practice
    Latto, IP
    Stacey, M
    Mecklenburgh, J
    Vaughan, RS
    [J]. ANAESTHESIA, 2002, 57 (04) : 379 - 384
  • [9] Devices for difficult airway management in academic emergency departments: Results of a national survey
    Levitan, RM
    Kush, S
    Hollander, JE
    [J]. ANNALS OF EMERGENCY MEDICINE, 1999, 33 (06) : 694 - 698
  • [10] Evaluation of the Upsherscope - A new rigid fiberscope
    Pearce, AC
    Shaw, S
    Macklin, S
    [J]. ANAESTHESIA, 1996, 51 (06) : 561 - 564