Cyclic Fatigue of Nickel-Titanium Rotary Instruments in a Double (S-shaped) Simulated Curvature

被引:60
作者
Al-Sudani, Dina [1 ]
Grande, Nicola M. [2 ]
Plotino, Gianluca [2 ]
Pompa, Giorgio [2 ]
Di Carlo, Stefano [2 ]
Testarelli, Luca [2 ]
Gambarini, Gianluca [2 ]
机构
[1] King Saud Univ, Dept Endodont, Riyadh, Saudi Arabia
[2] Univ Roma La Sapienza, Dept Oral Sci, Rome, Italy
关键词
Cyclic fatigue; double curvature; nickel-titanium; single curvature; ENDODONTIC INSTRUMENTS; FRACTURE; FILES;
D O I
10.1016/j.joen.2012.03.025
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The goal of the present study was to test the fatigue resistance of nickel-titanium rotary files in a double curvature (S-shaped) artificial root canal and to compare those results with single curvature artificial root canals. Methods: Two nickel-titanium endodontic instruments consisting of identical instrument sizes (constant .06 taper and 0.25 tip diameter) were tested, Pro File instruments and Vortex instruments. Both instruments were tested for fatigue inside an artificial canal with a double curvature and inside a curved artificial canal with a single curvature. Ten instruments for each group were tested to fracture in continuous rotary motion at 300 rpm. Number of cycles to failure (NCF) was calculated to the nearest whole number, and the length of the fractured fragment was measured in millimeters. Data were statistically analyzed with a level of significance set at 95% confidence level. Results: The NCF value was always statistically lower in the double curved artificial canal when compared with the single curve (P < .05) in both the apical and coronal curvatures. Statistically significant differences (P < .05) were noted between instruments of the same size of different brand only in the single curve; Pro File registered a mean of 633.5 +/- 75.1 NCF, whereas Vortex registered a mean of 548 +/- 48.9 NCF. Conclusions: Regardless of the differences between the instruments used in the present study, the results suggest. that the more complex is the root canal, the more adverse are the effects on the cyclic fatigue resistance of the instruments. (J Endod 2012;38:987-989)
引用
收藏
页码:987 / 989
页数:3
相关论文
共 23 条
[1]   Metallurgical Characterization of a New Nickel-Titanium Wire for Rotary Endodontic Instruments [J].
Alapati, Satish B. ;
Brantley, William A. ;
Iijima, Masahiro ;
Clark, William A. T. ;
Kovarik, Libor ;
Buie, Caesar ;
Liu, Jie ;
Ben Johnson, William .
JOURNAL OF ENDODONTICS, 2009, 35 (11) :1589-1593
[2]   Effect of environment on low-cycle fatigue of a nickel-titanium instrument [J].
Cheung, Gary S. P. ;
Shen, Ya ;
Darvell, Brian W. .
JOURNAL OF ENDODONTICS, 2007, 33 (12) :1433-1437
[3]   A dozen ways to prevent nickel-titanium rotary instrument fracture [J].
Di Fiore, Peter M. .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2007, 138 (02) :196-201
[4]   Fatigue resistance of engine-driven rotary nickel-titanium instruments produced by new manufacturing methods [J].
Gambarini, Gianluca ;
Grande, Nicola Maria ;
Plotino, Gianluca ;
Somma, Francesco ;
Garala, Manish ;
De Luca, Massimo ;
Testarelli, Luca .
JOURNAL OF ENDODONTICS, 2008, 34 (08) :1003-1005
[5]   Effects of Raw Material and Rotational Speed on the Cyclic Fatigue of ProFile Vortex Rotary Instruments [J].
Gao, Yong ;
Shotton, Vincent ;
Wilkinson, Kevin ;
Phillips, Greg ;
Ben Johnson, William .
JOURNAL OF ENDODONTICS, 2010, 36 (07) :1205-1209
[6]   Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments [J].
Haïkel, Y ;
Serfaty, R ;
Bateman, G ;
Senger, B ;
Allemann, C .
JOURNAL OF ENDODONTICS, 1999, 25 (06) :434-440
[7]   Cyclic fatigue of ProTaper rotary nickel-titanium instruments in artificial canals with 2 different radii of curvature [J].
Inan, Ugur ;
Aydin, Cumhur ;
Tunca, Yasar M. .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2007, 104 (06) :837-840
[8]  
Ingle J., 2002, Endodontics
[9]   Cyclic Fatigue and Fracture Characteristics of Ground and Twisted Nickel-Titanium Rotary Files [J].
Kim, Hyeon-Cheol ;
Yum, Jiwan ;
Hur, Bock ;
Cheung, Gary Shun-Pan .
JOURNAL OF ENDODONTICS, 2010, 36 (01) :147-152
[10]   Stress distribution of three NiTi rotary files under bending and torsional conditions using a mathematic analysis [J].
Kim, T. O. ;
Cheung, G. S. P. ;
Lee, J. M. ;
Kim, B. M. ;
Hur, B. ;
Kim, H. C. .
INTERNATIONAL ENDODONTIC JOURNAL, 2009, 42 (01) :14-21