Simultaneous determination of hydrochlorothiazide, quinapril and quinaprilat in human plasma by liquid chromatography-tandem mass spectrometry

被引:23
作者
Parekh, Sagar A. [1 ,2 ]
Pudage, Ashutosh [2 ]
Joshi, Santosh S. [2 ]
Vaidya, Vikas V. [1 ]
Gomes, Noel A. [2 ]
Kamat, Sudhir S. [1 ]
机构
[1] Ramnarain Ruia Coll, Dept Chem, Bombay, Maharashtra, India
[2] Accutest Res Labs I Pvt Ltd, Khairane, Navi Mumbai, India
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2008年 / 873卷 / 01期
关键词
hydrochlorothiazide; quinapril; quinaprilat LC-MS/MS; multiple reaction monitoring (MRM);
D O I
10.1016/j.jchromb.2008.07.046
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the simultaneous estimation of hydrochlorothiazide, quinapril and its metabolite quinaprilat in human plasma. After solid phase extraction (SPE), the analytes and IS were chromatographed on a hypurity C8 (100 mm x 2.1 mm i.d., 5 mu m particle size) column using 2 mu L injection volume with a run time of 2.8 min. An isocratic mobile phase consisting of 0.5% (v/v) formic acid:acetonitrile (25:75, v/v) was used to separate all these drugs. The precursor and product ions of these drugs were monitored on a triple quadrupole mass spectrometer, operating in the multiple reaction monitoring mode (MRM) without polarity switch. The proposed method was validated over the range of 5-500 ng/mL for hydrochlorothiazide method and 5-1500 ng/mL for quinapril and quinaprilat. Inter-batch and intra-batch precision (coefficient of variation - % CV) across five validation runs lower limit of quantitation (LLOQ), lower quality control (LQC), middle quality control (MQC), higher quality control (HQC) and upper limit of quantitation (ULOQ) was less than 15. The accuracy determined at these levels was within +/- 13% in terms of relative percentage error. (C) 2008 Published by Elsevier B.V.
引用
收藏
页码:59 / 69
页数:11
相关论文
共 18 条
[1]   Simultaneous determination of quinapril and its active metabolite quinaprilat in human plasma using high-performance liquid chromatography with ultraviolet detection [J].
Abbara, C ;
Aymard, G ;
Hinh, S ;
Diquet, B .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 766 (02) :199-207
[2]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY FOR HYDROCHLOROTHIAZIDE IN HUMAN-URINE [J].
ALTON, KB ;
DESRIVIERES, D ;
PATRICK, JE .
JOURNAL OF CHROMATOGRAPHY, 1986, 374 (01) :103-110
[3]  
[Anonymous], 2001, Guidance for industry, bioanalytical method validation
[4]   DETERMINATION OF HYDROCHLOROTHIAZIDE IN SERUM BY HIGH-PRESSURE LIQUID-CHROMATOGRAPHY [J].
CHRISTOPHERSEN, AS ;
RASMUSSEN, KE ;
SALVESEN, B .
JOURNAL OF CHROMATOGRAPHY, 1977, 132 (01) :91-97
[5]  
CONNIE T, 1990, AZUMAYA J CHROMATO B, V532, P168
[6]   DETERMINATION OF QUINAPRIL AND ITS ACTIVE METABOLITE IN HUMAN-PLASMA AND URINE BY GAS-CHROMATOGRAPHY WITH ELECTRON-CAPTURE DETECTION [J].
FERRY, JJ ;
HORVATH, AM ;
EASTONTAYLOR, M ;
TOOTHAKER, RD ;
COLBURN, WA .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 421 (01) :187-191
[7]   TRACE ANALYSIS OF QUINAPRIL AND ITS ACTIVE METABOLITE, QUINAPRILAT, IN HUMAN PLASMA AND URINE BY GAS-CHROMATOGRAPHY NEGATIVE-ION CHEMICAL IONIZATION MASS-SPECTROMETRY [J].
GOTO, N ;
KAMATA, T ;
IKEGAMI, K .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 578 (02) :195-201
[8]  
GUMIENICZEK A, 1998, PHARM ACTA HELV, V73, P183
[9]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF HYDROCHLOROTHIAZIDE IN PLASMA AND URINE [J].
KOOPMANS, PP ;
TAN, Y ;
VANGINNEKEN, CAM ;
GRIBNAU, FWJ .
JOURNAL OF CHROMATOGRAPHY, 1984, 307 (02) :445-450
[10]   Simultaneous densitometric determination of quinapril and hydrochlorothiazide in the combination tablets [J].
Kowalczuk, D ;
Hopkala, H ;
Pietras, R .
JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2003, 16 (03) :196-200