MRI-Guided Vacuum-Assisted Breast Biopsy Performed at 3 T With a 9-Gauge Needle: Preliminary Experience

被引:14
作者
Dogan, Basak E. [1 ,2 ]
Le-Petross, C. Huong [1 ,2 ]
Stafford, Jason R. [3 ]
Atkinson, Neely [4 ]
Whitman, Gary J. [1 ,2 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiol, Houston, TX 77030 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Breast Imaging, Houston, TX 77030 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
[4] Univ Texas MD Anderson Canc Ctr, Dept Biostat, Houston, TX 77030 USA
关键词
3; T; breast MRI; MRI-guided breast biopsy; FEASIBILITY; CANCER;
D O I
10.2214/AJR.11.8055
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to test the feasibility of 3-T vacuum-assisted large-bore core biopsy of lesions detected with MRI of the breast. CONCLUSION. Our preliminary experience revealed that 3-T MRI-guided vacuum-assisted biopsy is a safe and effective interventional method that enables accurate biopsy of lesions identified with a 3-T MRI system. Artifacts on 3-T images did not result in failed biopsy; therefore, 3-T MRI systems can be used reliably for both diagnostic and interventional breast studies.
引用
收藏
页码:W651 / W653
页数:3
相关论文
共 9 条
[1]   Positive predictive value for malignancy on surgical excision of breast lesions of uncertain malignant potential (B3) diagnosed by stereotactic vacuum-assisted needle core biopsy (VANCB): A large multi-institutional study in Italy [J].
Bianchi, S. ;
Caini, S. ;
Renne, G. ;
Cassano, E. ;
Ambrogetti, D. ;
Cattani, M. G. ;
Saguatti, G. ;
Chiaramondia, M. ;
Bellotti, E. ;
Bottiglieri, R. ;
Ancona, A. ;
Piubello, Q. ;
Montemezzi, S. ;
Ficarra, G. ;
Mauri, C. ;
Zito, F. A. ;
Ventrella, V. ;
Baccini, P. ;
Calabrese, M. ;
Palli, D. .
BREAST, 2011, 20 (03) :264-270
[2]   Increasing Accuracy of Detection of Breast Cancer with 3-T MRI [J].
Elsamaloty, Haitham ;
Elzawawi, Mohamed Salah ;
Mohammad, Shaden ;
Herial, Nabeel .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (04) :1142-1148
[3]   Efficacy of MRI and mammography for breast-cancer screening in women with a familial or genetic predisposition [J].
Kriege, M ;
Brekelmans, CTM ;
Boetes, C ;
Besnard, PE ;
Zonderland, HM ;
Obdeijn, IM ;
Manoliu, RA ;
Kok, T ;
Peterse, H ;
Tilanus-Linthorst, MMA ;
Muller, SH ;
Meijer, S ;
Oosterwijk, JC ;
Beex, LVAM ;
Tollenaar, RAEM ;
de Koning, HJ ;
Rutgers, EJT ;
Klijn, JGM .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 351 (05) :427-437
[4]   Contrast-enhanced MR imaging of the breast at 3.0 and 1.5 T in the same patients: Initial experience [J].
Kuhl, CK ;
Jost, P ;
Morakkabati, N ;
Zivanovic, O ;
Schild, HH ;
Gieseke, J .
RADIOLOGY, 2006, 239 (03) :666-676
[5]   Biopsy sampling of breast lesions: comparison of core needle- and vacuum-assisted breast biopsies [J].
Lacambra, Maribel D. ;
Lam, Christopher C. ;
Mendoza, Paulo ;
Chan, Siu Ki ;
Yu, Alex M. ;
Tsang, Julia Y. S. ;
Tan, Puay Hoon ;
Tse, Gary M. .
BREAST CANCER RESEARCH AND TREATMENT, 2012, 132 (03) :917-923
[6]   MRI-guided 9-gauge vacuum-assisted breast biopsy: Initial clinical experience [J].
Liberman, L ;
Bracero, N ;
Morris, E ;
Thornton, C ;
Dershaw, DD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (01) :183-193
[7]   MRI-guided breast biopsy at 3T using a dedicated large core biopsy set: Feasibility and initial results [J].
Meeuwis, Carla ;
Mann, Ritse M. ;
Mus, Roel. D. M. ;
Winkel, Axel ;
Boetes, Carla ;
Barentsz, Jelle O. ;
Veltman, Jeroen .
EUROPEAN JOURNAL OF RADIOLOGY, 2011, 79 (02) :257-261
[8]   MR imaging-guided 9-gauge vacuum-assisted core-needle breast biopsy: Initial experience [J].
Orel, SG ;
Rosen, M ;
Mies, C ;
Schnall, MD .
RADIOLOGY, 2006, 238 (01) :54-61
[9]   Feasibility of MRI-guided large-core-needle biopsy of suspiscious breast lesions at 3 T [J].
Peters, Nicky H. G. M. ;
Meeuwis, Carla ;
Bakker, Chris J. G. ;
Mali, Willem P. Th. M. ;
Fernandez-Gallardo, Arancha M. ;
van Hillegersberg, Richard ;
Schipper, Marguerite E. I. ;
van den Bosch, Maurice A. A. J. .
EUROPEAN RADIOLOGY, 2009, 19 (07) :1639-1644