Electroanalysis at Single Gold Nanowire Electrodes

被引:51
作者
Dawson, Karen [1 ]
Wahl, Amelie [1 ]
Murphy, Richard [1 ]
O'Riordan, Alan [1 ]
机构
[1] Natl Univ Ireland Univ Coll Cork, Tyndall Natl Inst, Cork, Ireland
基金
爱尔兰科学基金会;
关键词
SCANNING ELECTROCHEMICAL MICROSCOPY; NANOELECTRODE ENSEMBLES; NANOMETER DIMENSIONS; TRANSFER KINETICS; FABRICATION; ARRAYS; MICROELECTRODES; NANOPARTICLES; PLATINUM; SENSORS;
D O I
10.1021/jp302967p
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In this work, we report the fabrication and in-depth electrochemical analysis of discrete gold nanowire electrodes for use in electrochemical applications. The single nanowire electrodes were fabricated using a hybrid E-beam/photolithography approach at silicon substrates, providing electrodes with well-defined and reproducible dimensions Following fabrication, nanowire devices were characterized by electrical and electrochemical techniques Low electrical resistances with typical linear Ohmic responses were observed from fully packaged electrode devices. Finite element diffusion domain simulation studies were undertaken to explore analyte mass transport to nanowire electrodes at a variety of scan rates. Simulation results suggested that radial analyte diffusion profiles to nanoelectrodes should be present at fast scan rates. This behavior was confirmed experimentally where cyclic voltammograms obtained in ferrocenemonocarboxylic acid were observed to be steady-state, with high measurable currents (nA) and sigmoidal up to 1000 mV s(-1) Nanowire electrodes had very low capacitance, similar to 37 +/- 6 nF cm(-2) per nanowire, 3 orders of magnitude lower than that typically achieved by ultramicroelectrodes. The electrochemical responses of nanowires, in model redox mediators, were excellently described by Butler-Volmer kinetics. The nanowire electrodes are applied to reproducible determination of heterogeneous electron transfer rate constants, k(0), for three key model redox analytes, FcCOOH, Fe(II)(CN)(6)(4-), and Ru(NH3)(6)(3+).
引用
收藏
页码:14665 / 14673
页数:9
相关论文
共 45 条
  • [1] [Anonymous], 2001, ELECTROCHEMICAL METH
  • [2] Electrochemical biosensor for targeted detection in blood using aligned Au nanowires
    Aravamudhan, Shyarn
    Ramgir, Niranjan S.
    Bhansah, Shekhar
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2007, 127 (01) : 29 - 35
  • [3] Nanoelectrodes, nanoelectrode arrays and their applications
    Arrigan, DWM
    [J]. ANALYST, 2004, 129 (12) : 1157 - 1165
  • [4] Independent geometrical and electrochemical characterization of arrays of nanometer-scale electrodes
    Baker, WS
    Crooks, RM
    [J]. JOURNAL OF PHYSICAL CHEMISTRY B, 1998, 102 (49) : 10041 - 10046
  • [5] SCANNING ELECTROCHEMICAL MICROSCOPY .12. THEORY AND EXPERIMENT OF THE FEEDBACK MODE WITH FINITE HETEROGENEOUS ELECTRON-TRANSFER KINETICS AND ARBITRARY SUBSTRATE SIZE
    BARD, AJ
    MIRKIN, MV
    UNWIN, PR
    WIPF, DO
    [J]. JOURNAL OF PHYSICAL CHEMISTRY, 1992, 96 (04) : 1861 - 1868
  • [6] Baron R, 2008, INT J ELECTROCHEM SC, V3, P556
  • [7] Development of an electrochemical sensor nanoarray for hydrazine detection using a combinatorial approach
    Baron, Ronan
    Sljukic, Biljana
    Salter, Chris
    Crossley, Alison
    Compton, Richard G.
    [J]. ELECTROANALYSIS, 2007, 19 (10) : 1062 - 1068
  • [8] Voltammetric characterisation of silicon-based microelectrode arrays and their application to mercury-free stripping voltammetry of copper ions
    Berduque, Alfonso
    Lanyon, Yvonne H.
    Beni, Valerio
    Herzog, Gregoire
    Watson, Yvonne E.
    Rodgers, Kenneth
    Stam, Frank
    Alderman, John
    Arrigan, Damien W. M.
    [J]. TALANTA, 2007, 71 (03) : 1022 - 1030
  • [9] Fabrication of carbon microelectrodes with an effective radius of 1 nm
    Chen, SL
    Kucernak, A
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2002, 4 (01) : 80 - 85
  • [10] The voltammetric response of nanometer-sized carbon electrodes
    Chen, SL
    Kucernak, A
    [J]. JOURNAL OF PHYSICAL CHEMISTRY B, 2002, 106 (36) : 9396 - 9404