Real-Time Bioimpedance-Based Biopsy Needle Can Identify Tissue Type with High Spatial Accuracy

被引:29
作者
Halonen, Sanna [1 ,2 ,3 ]
Kari, Juho [1 ]
Ahonen, Petri [1 ]
Kronstrom, Kai [1 ]
Hyttinen, Jari [2 ,3 ]
机构
[1] Injeq Ltd, R&D Dept, Hermiankatu 22, Tampere 33720, Finland
[2] Tampere Univ Technol, BioMediTech Inst, Korkeakoulunkatu 10, Tampere, Finland
[3] Tampere Univ Technol, Fac Biomed Sci & Engn, Korkeakoulunkatu 10, Tampere, Finland
关键词
Tissue classification; In vivo; Animal study; Simulations; Tissue properties; Liver; Hepatic tissue; PROBE BIP NEEDLE; DIELECTRIC-PROPERTIES; NORMAL LIVER; IN-VIVO; IMPEDANCE; BAND; DISCRIMINATION; SPECTROSCOPY; CARCINOMA;
D O I
10.1007/s10439-018-02187-9
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Histological analysis is meaningful in diagnosis only if the targeted tissue is obtained in the biopsy. Often, physicians have to take a tissue sample without accurate information about the location of the instrument tip. A novel biopsy needle with bioimpedance-based tissue identification has been developed to provide data for the automatic classification of the tissue type at the tip of the needle. The aim of this study was to examine the resolution of this identification method and to assess how tissue heterogeneities affect the measurement and tissue classification. Finite element method simulations of bioimpedance measurements were performed using a 3D model. In vivo data of a porcine model were gathered with a moving needle from fat, muscle, blood, liver, and spleen, and a tissue classifier was created and tested based on the gathered data. Simulations showed that very small targets were detectable, and targets of 2 x 2 x 2 mm(3) and larger were correctly measurable. Based on the in vivo data, the performance of the tissue classifier was high. The total accuracy of classifying different tissues was approximately 94%. Our results indicate that local bioimpedance-based tissue classification is feasible in vivo, and thus the method provides high potential to improve clinical biopsy procedures.
引用
收藏
页码:836 / 851
页数:16
相关论文
共 30 条
  • [11] Measurement of bio-impedance with a smart needle to confirm percutaneous kidney access
    Hernandez, DJ
    Sinkov, VA
    Roberts, WW
    Allaf, ME
    Patriciu, A
    Jarrett, TW
    Kavoussi, LR
    Stoianovici, D
    [J]. JOURNAL OF UROLOGY, 2001, 166 (04) : 1520 - 1523
  • [12] Detection of intraneural needle-placement with multiple frequency bioimpedance monitoring: a novel method
    Kalvoy, Havard
    Sauter, Axel R.
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2016, 30 (02) : 185 - 192
  • [13] Impedance-based tissue discrimination for needle guidance
    Kalvoy, Havard
    Frich, Lars
    Grimnes, Sverre
    Martinsen, Orjan G.
    Hol, Per Kristian
    Stubhaug, Audun
    [J]. PHYSIOLOGICAL MEASUREMENT, 2009, 30 (02) : 129 - 140
  • [14] Kari J, 2015, THIN NEEDLE BIOIMPED
  • [15] Kauppinen P., 2006, Int. J. Bioelectromagn, V8, P1
  • [16] Sensitivity distributions of impedance cardiography using band and spot electrodes analyzed by a three-dimensional computer model
    Kauppinen, PK
    Hyttinen, JA
    Malmivuo, JA
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 1998, 26 (04) : 694 - 702
  • [17] Lead field theoretical approach in bioimpedance measurements:: Towards more controlled measurement sensitivity
    Kauppinen, PK
    Hyttinen, JA
    Kööbi, T
    Malmivuo, J
    [J]. ELECTRICAL BIOIMPEDANCE METHODS: APPLICATIONS TO MEDICINE AND BIOTECHNOLOGY, 1999, 873 : 135 - 142
  • [18] Recording characteristics of electrical impedance myography needle electrodes
    Kwon, H.
    Rutkove, S. B.
    Sanchez, B.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2017, 38 (09) : 1748 - 1765
  • [19] Electrical impedance characterization of normal and cancerous human hepatic tissue
    Laufer, Shlomi
    Ivorra, Antoni
    Reuter, Victor E.
    Rubinsky, Boris
    Solomon, Stephen B.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2010, 31 (07) : 995 - 1009
  • [20] Lee BR, 1999, PROSTATE, V39, P213, DOI 10.1002/(SICI)1097-0045(19990515)39:3<213::AID-PROS10>3.0.CO