Analysis of bisphenol A in natural waters by means of an optical immunosensor

被引:81
作者
Rodriguez-Mozaz, S [1 ]
de Alda, ML [1 ]
Barceló, D [1 ]
机构
[1] CSIC, Dept Environm Chem, IIQAB, ES-08034 Barcelona, Spain
关键词
immunosensor; bisphenol A; water; waterworks;
D O I
10.1016/j.watres.2005.09.023
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This work describes a very simple, fast and sensitive method based on the use of the optical immunosensor '' River Analyser '' (RIANA) to the determination of bisphenol A in a waters. RIANA is based on a rapid solid-phase indirect inhibition immunoassay that takes place at an optical transducer chip chemically modified with an analyte derivative. Fluorescence produced by labelled antibodies bound to the transducer is detected by photodiodes and can be correlated with the analyte concentration. The sensor surface can be regenerated thus allowing the performance of several measurements (around 300) with the same transducer. Each test cycle, including one regeneration step, is accomplished in 15 ruin. The detection limit achieved in the direct determination of bisphenol A in water with this system was 0.014 mu g/L. Satisfactory repeatability, with relative standard deviations (RSD) ranging between 1.48% and 6.93% were obtained. The immunosensor method developed was applied to the monitoring of bisphenol A in various types of water collected in a waterworks (from the river water source to the finished drinking water) and validated against the results obtained in the same approach by a more traditional method, based on solid-phase extraction followed by liquid chromatography-mass spectrometry. Results obtained by both techniques were in general good agreement (considering the typical overestimation bias of immunoassays), and served to prove the satisfactory removal efficiency of the overall purification process applied in the waterworks and, in particular, of the sand filtration step. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:5071 / 5079
页数:9
相关论文
共 44 条
[31]   Parent bisphenol A accumulation in the human maternal-fetal-placental unit [J].
Schönfelder, G ;
Wittfoht, W ;
Hopp, H ;
Talsness, CE ;
Paul, M ;
Chahoud, I .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2002, 110 (11) :A703-A707
[32]   Highly sensitive dioxin immunoassay and its application to soil and biota samples [J].
Shan, G ;
Leeman, WR ;
Gee, SJ ;
Sanborn, JR ;
Jones, AD ;
Chang, DPY ;
Hammock, BD .
ANALYTICA CHIMICA ACTA, 2001, 444 (01) :169-178
[33]   Sensitive determination of bisphenol A in environmental water by gas chromatography with nitrogen-phosphorus detection after cyanomethylation [J].
Shin, HS ;
Park, CH ;
Park, SJ ;
Pyo, H .
JOURNAL OF CHROMATOGRAPHY A, 2001, 912 (01) :119-125
[34]  
Soh N, 2003, SENSOR MATER, V15, P423
[35]   CYANINE DYE LABELING REAGENTS - CARBOXYMETHYLINDOCYANINE SUCCINIMIDYL ESTERS [J].
SOUTHWICK, PL ;
ERNST, LA ;
TAURIELLO, EW ;
PARKER, SR ;
MUJUMDAR, RB ;
MUJUMDAR, SR ;
CLEVER, HA ;
WAGGONER, AS .
CYTOMETRY, 1990, 11 (03) :418-430
[36]   Xenoestrogens in the River Elbe and its tributaries [J].
Stachel, B ;
Ehrhorn, U ;
Heemken, OP ;
Lepom, P ;
Reincke, H ;
Sawal, G ;
Theobald, N .
ENVIRONMENTAL POLLUTION, 2003, 124 (03) :497-507
[37]   A review of the environmental fate, effects, and exposures of bisphenol A [J].
Staples, CA ;
Dorn, PB ;
Klecka, GM ;
O'Block, ST ;
Harris, LR .
CHEMOSPHERE, 1998, 36 (10) :2149-2173
[38]   Bisphenol A suppresses osteoclastic and osteoblastic activities in the cultured scales of goldfish [J].
Suzuki, N ;
Hattori, A .
LIFE SCIENCES, 2003, 73 (17) :2237-2247
[39]   Atrazine interaction with tropical humic substances by Enzyme Linked Immunosorbent Assay [J].
Toscano, I ;
Gascon, J ;
Marco, MP ;
Rocha, JC ;
Barcelo, D .
ANALUSIS, 1998, 26 (03) :130-134
[40]   Automated water analyser computer supported system (AWACSS) Part II:: Intelligent, remote-controlled, cost-effective, on-line, water-monitoring measurement system [J].
Tschmelak, J ;
Proll, G ;
Riedt, J ;
Kaiser, J ;
Kraemmer, P ;
Bárzaga, L ;
Wilkinson, JS ;
Hua, P ;
Hole, JP ;
Nudd, R ;
Jackson, M ;
Abuknesha, R ;
Barceló, D ;
Rodriguez-Mozaz, S ;
de Alda, MJL ;
Sacher, F ;
Stien, J ;
Slobodník, J ;
Oswald, P ;
Kozmenko, H ;
Korenková, E ;
Tóthová, L ;
Krascsenits, Z ;
Gauglitz, G .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (08) :1509-1519