Esophageal Baseline Impedance From High-resolution Impedance Manometry Correlates With Mean Nocturnal Baseline Impedance From pH-impedance Monitoring

被引:6
作者
Horton, Anthony [1 ]
Sullivan, Brian [1 ,2 ]
Charles, Katie [1 ]
McIntosh, Thasha [2 ]
Davis, Andrea [2 ]
Gellad, Ziad [1 ,2 ]
Shimpi, Rahul [1 ]
Gyawali, C. Prakash [3 ]
Patel, Amit [1 ,2 ]
机构
[1] Duke Univ, Sch Med, Div Gastroenterol, DUMC Box 3913, Durham, NC 27710 USA
[2] Durham Vet Affairs Med Ctr, Durham, NC USA
[3] Washington Univ, Sch Med, Div Gastroenterol, St Louis, MO 63110 USA
关键词
Electric impedance; Esophageal mucosa; Esophageal pH monitoring; Gastroesophageal reflux; PROTON PUMP INHIBITORS; NORMAL VALUES; PARAMETERS; ASSOCIATION; DIAGNOSIS; OUTCOMES; YIELD; INDEX; GERD;
D O I
10.5056/jnm19142
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background/Aims Esophageal baseline impedance (BI) can be extracted from pH-impedance tracings as mean nocturnal baseline impedance (MNBI), and from high-resolution impedance manometry (HRIM), but it is unknown if values are similar between acquisition methods across HRIM manufacturers. We aim to assess correlations between MNBI and BI from HRIM (BI-HRIM) from 2 HRIM manufacturers in the setting of physiologic acid exposure time (AET). Methods HRIM and pH-impedance monitoring demonstrating physiologic AET (< 4%) off proton pump inhibitors were required. BI-HRIM was extracted as the average from 5 cm and 10 cm above the lower esophageal sphincter. Distal BI-HRIM (DBI-HRIM) was also extracted from the most distal channel (Medtronic studies). MNBI was extracted from 6 channels. Concordance between BI-HRIM across manufacturers with MNBI was analyzed. Results Thirty-six patients met the inclusion criteria (59.6 +/- 1.7 years; 22% female; body mass index 30.5 +/- 0.7; AET 1.6 +/- 0.2%). Although MNBI was similar at all channels (P >= 0.18), Diversatek BI-HRIM was lower than Medtronic BI-HRIM (P = 0.003). Overall, BI-HRIM correlated with MNBI at corresponding recording sites, 7 cm and 9 cm (P < 0.05), but not at other sites (P >= 0.19). Pearson's correlations > 0.5 were seen at MNBI at 7 cm for both systems, and at 9 cm for Medtronic. DBI-HRIM correlated with MNBI at 3 cm and 5 cm (P < 0.03), but not at other locations (P > 0.1). Conclusions While numeric differences exist between manufacturers, BI-HRIM correlates with MNBI from corresponding channels in patients with physiologic AET. Comparison with AET elevation is needed to determine correlations between pathologic MNBI with BI-HRIM across manufacturers. The optimal HRIM channels from which BI values should be extracted also warrants further study.
引用
收藏
页码:455 / 462
页数:8
相关论文
共 36 条
[1]   Mucosal Impedance Discriminates GERD From Non-GERD Conditions [J].
Ates, Fehmi ;
Yuksel, Elif Saritas ;
Higginbotham, Tina ;
Slaughter, James C. ;
Mabary, Jerry ;
Kavitt, Robert T. ;
Garrett, C. Gaelyn ;
Francis, David ;
Vaezi, Michael F. .
GASTROENTEROLOGY, 2015, 148 (02) :334-343
[2]   An analysis of distal esophageal impedance in individuals with and without esophageal motility abnormalities [J].
Blonski, Wojciech ;
Hila, Amine ;
Vela, Marcelo F. ;
Castell, Donald O. .
JOURNAL OF CLINICAL GASTROENTEROLOGY, 2008, 42 (07) :776-781
[3]   Normal values for esophageal high-resolution manometry [J].
Bogte, A. ;
Bredenoord, A. J. ;
Oors, J. ;
Siersema, P. D. ;
Smout, A. J. P. M. .
NEUROGASTROENTEROLOGY AND MOTILITY, 2013, 25 (09) :762-E579
[4]   Addition of esophageal impedance monitoring to pH monitoring increases the yield of symptom association analysis in patients off PPI therapy [J].
Bredenoord, AJ ;
Weusten, BLAM ;
Timmer, R ;
Conchillo, JM ;
Smout, AJPM .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2006, 101 (03) :453-459
[5]   Association Between Baseline Impedance Values and Response Proton Pump Inhibitors in Patients With Heartburn [J].
de Bortoli, Nicola ;
Martinucci, Irene ;
Savarino, Edoardo ;
Tutuian, Radu ;
Frazzoni, Marzio ;
Piaggi, Paolo ;
Bertani, Lorenzo ;
Furnari, Manuele ;
Franchi, Riccardo ;
Russo, Salvatore ;
Bellini, Massimo ;
Savarino, Vincenzo ;
Marchi, Santino .
CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2015, 13 (06) :1082-+
[6]   Evaluation of oesophageal mucosa integrity by the intraluminal impedance technique [J].
Farre, Ricard ;
Blondeau, Kathleen ;
Clement, Dominique ;
Vicario, Maria ;
Cardozo, Lucia ;
Vieth, Michael ;
Mertens, Veerle ;
Pauwels, Ans ;
Silny, Jiri ;
Jimenez, Marcel ;
Tack, Jan ;
Sifrim, Daniel .
GUT, 2011, 60 (07) :885-892
[7]   The added diagnostic value of postreflux swallow-induced peristaltic wave index and nocturnal baseline impedance in refractory reflux disease studied with on-therapy impedance-pH monitoring [J].
Frazzoni, M. ;
de Bortoli, N. ;
Frazzoni, L. ;
Tolone, S. ;
Furnari, M. ;
Martinucci, I. ;
Mirante, V. G. ;
Marchi, S. ;
Savarino, V. ;
Savarino, E. .
NEUROGASTROENTEROLOGY AND MOTILITY, 2017, 29 (03)
[8]   Analyses of the Post-reflux Swallow-induced Peristaltic Wave Index and Nocturnal Baseline Impedance Parameters Increase the Diagnostic Yield of Impedance-pH Monitoring of Patients With Reflux Disease [J].
Frazzoni, Marzio ;
Savarino, Edoardo ;
de Bortoli, Nicola ;
Martinucci, Irene ;
Furnari, Manuele ;
Frazzoni, Leonardo ;
Mirante, Vincenzo Giorgio ;
Bertani, Helga ;
Marchi, Santino ;
Conigliaro, Rita ;
Savarinok, Vincenzo .
CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2016, 14 (01) :40-46
[9]   AMBULATORY 24 HOUR INTRAESOPHAGEAL PH AND PRESSURE RECORDINGS V PROVOCATION TESTS IN THE DIAGNOSIS OF CHEST PAIN OF ESOPHAGEAL ORIGIN [J].
GHILLEBERT, G ;
JANSSENS, J ;
VANTRAPPEN, G ;
NEVENS, F ;
PIESSENS, J .
GUT, 1990, 31 (07) :738-744
[10]   ACG Clinical Guidelines: Clinical Use of Esophageal Physiologic Testing [J].
Gyawali, C. Prakash ;
Carlson, Dustin A. ;
Chen, Joan W. ;
Patel, Amit ;
Wong, Robert J. ;
Yadlapati, Rena H. .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2020, 115 (09) :1412-1428