Monte Carlo calculation of dose distributions in oligometastatic patients planned for spine stereotactic ablative radiotherapy

被引:4
|
作者
Moiseenko, V. [1 ]
Liu, M. [2 ]
Loewen, S. [2 ]
Kosztyla, R. [2 ]
Vollans, E. [2 ]
Lucido, J. [2 ]
Fong, M. [2 ]
Vellani, R. [2 ]
Popescu, I. A. [2 ]
机构
[1] Univ Calif San Diego, La Jolla, CA 92093 USA
[2] British Columbia Canc Agcy, Vancouver, BC V5Z 4E6, Canada
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2013年 / 58卷 / 20期
关键词
BODY RADIATION-THERAPY; WATER; SIMULATIONS; SBRT;
D O I
10.1088/0031-9155/58/20/7107
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Dosimetric consequences of plans optimized using the analytical anisotropic algorithm (AAA) implemented in the Varian Eclipse treatment planning system for spine stereotactic body radiotherapy were evaluated by re-calculating with BEAMnrc/DOSXYZnrc Monte Carlo. Six patients with spinal vertebral metastases were planned using volumetricmodulated arc therapy. The planning goal was to cover at least 80% of the planning target volume with a prescribed dose of 35 Gy in five fractions. Tissue heterogeneity-corrected AAA dose distributions for the planning target volume and spinal canal planning organ-at-risk volume were compared against those obtained from Monte Carlo. The results showed that the AAA overestimated planning target volume coverage with the prescribed dose by up to 13.5% (mean 8.3% +/- 3.2%) when compared to Monte Carlo simulations. Maximum dose to spinal canal planning organ-at-risk volume calculated with Monte Carlo was consistently smaller than calculated with the treatment planning system and remained under spinal cord dose tolerance. Differences in dose distribution appear to be related to the dosimetric effects of accounting for body composition in Monte Carlo simulations. In contrast, the treatment planning system assumes that all tissues are water-equivalent in their composition and only differ in their electron density.
引用
收藏
页码:7107 / 7116
页数:10
相关论文
共 50 条
  • [41] ELECTRON DOSE DISTRIBUTIONS IN INHOMOGENEOUS PHANTOMS: A MONTE CARLO STUDY
    Mihailescu, D.
    Borcia, C.
    ROMANIAN REPORTS IN PHYSICS, 2018, 70 (03)
  • [42] COMPARISON OF PLANNED DOSE DISTRIBUTIONS CALCULATED BY MONTE CARLO AND RAY-TRACE ALGORITHMS FOR THE TREATMENT OF LUNG TUMORS WITH CYBERKNIFE: A PRELIMINARY STUDY IN 33 PATIENTS
    Wilcox, Ellen E.
    Daskalov, George M.
    Lincoln, Holly
    Shumway, Richard C.
    Kaplan, Bruce M.
    Colasanto, Joseph M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 77 (01): : 277 - 284
  • [43] Phase 2 Trial of Stereotactic Ablative Radiotherapy for Patients with Renal Cancer
    Hannan, Raquibul
    McLaughlin, Mark F.
    Pop, Laurentiu M.
    Pedrosa, Ivan
    Kapur, Payal
    Garant, Aurelie
    Ahn, Chul
    Christie, Alana
    Zhu, James
    Wangg, Tao
    Robles, Liliana
    Durakoglugil, Deniz
    Woldu, Solomon
    Margulis, Vitaly
    Gahan, Jeffrey
    Brugarolas, James
    Timmerman, Robert
    Cadeddu, Jeffrey
    EUROPEAN UROLOGY, 2023, 84 (03) : 275 - 286
  • [44] Repeated stereotactic ablative radiotherapy using CyberKnife for patients with hepatocellular carcinoma
    Lo, Cheng-Hsiang
    Huang, Wen-Yen
    Lin, Kuen-Tze
    Lin, Miao-Jung
    Lin, Te-Pao
    Jen, Yee-Min
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2014, 29 (11) : 1919 - 1925
  • [45] Validation of fast Monte Carlo dose calculation in small animal radiotherapy with EBT3 radiochromic films
    Noblet, C.
    Chiavassa, S.
    Smekens, F.
    Sarrut, D.
    Passal, V.
    Suhard, J.
    Lisbona, A.
    Paris, F.
    Delpon, G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (09): : 3521 - +
  • [46] Unsupervised classification of tissues composition for Monte Carlo dose calculation
    Lalonde, Arthur
    Remy, Charlotte
    Simard, Mikael
    Bouchard, Hugo
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (15):
  • [47] Available evidence on re-irradiation with stereotactic ablative radiotherapy following high-dose previous thoracic radiotherapy for lung malignancies
    De Bari, Berardino
    Filippi, Andrea Riccardo
    Mazzola, Rosario
    Bonomo, Pierluigi
    Trovo, Marco
    Livi, Lorenzo
    Alongi, Filippo
    CANCER TREATMENT REVIEWS, 2015, 41 (06) : 511 - 518
  • [48] Metabolic factors associated with the prognosis of oligometastatic patients treated with stereotactic body radiotherapy
    Klement, Rainer J.
    Sweeney, Reinhart A.
    CANCER AND METASTASIS REVIEWS, 2023, 42 (03) : 927 - 940
  • [49] Metabolic factors associated with the prognosis of oligometastatic patients treated with stereotactic body radiotherapy
    Rainer J. Klement
    Reinhart A. Sweeney
    Cancer and Metastasis Reviews, 2023, 42 : 927 - 940
  • [50] INFLUENCE OF ROTATIONS ON DOSE DISTRIBUTIONS IN SPINAL STEREOTACTIC BODY RADIOTHERAPY (SBRT)
    Gutfeld, Orit
    Kretzler, Annette E.
    Kashani, Rojano
    Tatro, Daniel
    Balter, James M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (05): : 1596 - 1601