Monte Carlo calculation of dose distributions in oligometastatic patients planned for spine stereotactic ablative radiotherapy

被引:4
|
作者
Moiseenko, V. [1 ]
Liu, M. [2 ]
Loewen, S. [2 ]
Kosztyla, R. [2 ]
Vollans, E. [2 ]
Lucido, J. [2 ]
Fong, M. [2 ]
Vellani, R. [2 ]
Popescu, I. A. [2 ]
机构
[1] Univ Calif San Diego, La Jolla, CA 92093 USA
[2] British Columbia Canc Agcy, Vancouver, BC V5Z 4E6, Canada
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2013年 / 58卷 / 20期
关键词
BODY RADIATION-THERAPY; WATER; SIMULATIONS; SBRT;
D O I
10.1088/0031-9155/58/20/7107
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Dosimetric consequences of plans optimized using the analytical anisotropic algorithm (AAA) implemented in the Varian Eclipse treatment planning system for spine stereotactic body radiotherapy were evaluated by re-calculating with BEAMnrc/DOSXYZnrc Monte Carlo. Six patients with spinal vertebral metastases were planned using volumetricmodulated arc therapy. The planning goal was to cover at least 80% of the planning target volume with a prescribed dose of 35 Gy in five fractions. Tissue heterogeneity-corrected AAA dose distributions for the planning target volume and spinal canal planning organ-at-risk volume were compared against those obtained from Monte Carlo. The results showed that the AAA overestimated planning target volume coverage with the prescribed dose by up to 13.5% (mean 8.3% +/- 3.2%) when compared to Monte Carlo simulations. Maximum dose to spinal canal planning organ-at-risk volume calculated with Monte Carlo was consistently smaller than calculated with the treatment planning system and remained under spinal cord dose tolerance. Differences in dose distribution appear to be related to the dosimetric effects of accounting for body composition in Monte Carlo simulations. In contrast, the treatment planning system assumes that all tissues are water-equivalent in their composition and only differ in their electron density.
引用
收藏
页码:7107 / 7116
页数:10
相关论文
共 50 条
  • [21] Esophageal tolerance to high-dose stereotactic ablative radiotherapy
    Abelson, J. A.
    Murphy, J. D.
    Loo, B. W., Jr.
    Chang, D. T.
    Daly, M. E.
    Wiegner, E. A.
    Hancock, S.
    Chang, S. D.
    Le, Q. -T.
    Soltys, S. G.
    Gibbs, I. C.
    DISEASES OF THE ESOPHAGUS, 2012, 25 (07) : 623 - 629
  • [22] Intensified systemic therapy and stereotactic ablative radiotherapy dose for patients with unresectable pancreatic adenocarcinoma
    Toesca, Diego A. S.
    Ahmed, Faisal
    Kashyap, Mehr
    Baclay, J. Richelcyn M.
    von Eyben, Rie
    Pollom, Erqi L.
    Koong, Albert C.
    Chang, Daniel T.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : 63 - 69
  • [23] Stereotactic body radiotherapy as local management for oligometastatic patients
    Gonzalez de Duenas, Maria
    Corral Fernandez, Carmen
    Agudo Rey, Esther
    Medina Cobacho, Maria
    Ruiz Leal, Patricia
    Vera Barragan, Victoria
    Cabrera Rodriguez, Joaquin
    Rios Kavadoy, Yesika
    Quiros Rivero, Juan
    Ropero Carmona, Maria Francisca
    Iglesias Garcia, Teresa
    Munoz Garcia, Julia
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S1938 - S1941
  • [24] Commissioning and validation of a Monte Carlo algorithm for spine stereotactic radiosurgery
    Knill, Cory
    Sandhu, Raminder
    Loughery, Brian
    Lin, Lifeng
    Halford, Robert
    Drake, Doug
    Snyder, Michael
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (11):
  • [25] The role of stereotactic ablative radiotherapy (SBRT) in the management of oligometastatic non small cell lung cancer
    Guerrero, Eduardo
    Ahmed, Merina
    LUNG CANCER, 2016, 92 : 22 - 28
  • [26] Safety and Survival Rates Associated With Ablative Stereotactic Radiotherapy for Patients With Oligometastatic Cancer A Systematic Review and Meta-analysis
    Lehrer, Eric J.
    Singh, Raj
    Wang, Ming
    Chinchilli, Vernon M.
    Trifiletti, Daniel M.
    Ost, Piet
    Siva, Shankar
    Meng, Mao-bin
    Tchelebi, Leila
    Zaorsky, Nicholas G.
    JAMA ONCOLOGY, 2021, 7 (01) : 92 - 106
  • [27] Comparative analysis of delivered and planned doses in target volumes for lung stereotactic ablative radiotherapy
    Yu, Geum Bong
    Kim, Jung In
    Kim, Hak Jae
    Lee, Seungwan
    Choi, Chang Heon
    Kang, Seonghee
    RADIATION ONCOLOGY, 2024, 19 (01)
  • [28] Performance of dose calculation algorithms from three generations in lung SBRT: comparison with full Monte Carlo-based dose distributions
    Ojala, Jarkko J.
    Kapanen, Mika K.
    Hyodynmaa, Simo J.
    Wigren, Tuija K.
    Pitkanen, Maunu A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (02): : 4 - 18
  • [29] Stereotactic Ablative Radiotherapy (SABR) in inoperable oligometastatic disease from colorectal cancer: a safe and effective approach
    Comito, Tiziana
    Cozzi, Luca
    Clerici, Elena
    Campisi, Maria Concetta
    Liardo, Rocco Luca Emanuele
    Navarria, Pierina
    Ascolese, AnnaMaria
    Tozzi, Angelo
    Iftode, Cristina
    De Rose, Fiorenza
    Villa, Elisa
    Personeni, Nicola
    Rimassa, Lorenza
    Santoro, Armando
    Fogliata, Antonella
    Mancosu, Pietro
    Tomatis, Stefano
    Scorsetti, Marta
    BMC CANCER, 2014, 14
  • [30] Low-Burden Oligometastatic Disease of the Lung Treated with Robotic Stereotactic Ablative Radiotherapy: A Retrospective Study
    Zygogianni, Anna
    Koukourakis, Ioannis M.
    Liakouli, Zoi
    Desse, Dimitra
    Georgakopoulos, Ioannis
    Armpilia, Christina
    Lymperopoulou, Georgia
    Kouloulias, Vasileios
    BIOMEDICINES, 2025, 13 (02)