Changes in supramaximal M-wave amplitude at different regions of biceps brachii following eccentric exercise of the elbow flexors

被引:1
作者
Cabral, Helio V. [1 ]
Meiburger, Kristen M. [2 ,3 ]
de Oliveira, Liliam F. [1 ,4 ]
Vieira, Taian M. [3 ,5 ]
机构
[1] Univ Fed Rio de Janeiro, Biomech Lab, Biomed Engn Program COPPE, Rio De Janeiro, Brazil
[2] Politecn Torino, Biolab, Dept Elect & Telecommun, Turin, Italy
[3] Politecn Torino, PolitoBIOMed Lab, Turin, Italy
[4] Univ Fed Rio de Janeiro, PolitoBIOMed Lab, Rio De Janeiro, Brazil
[5] Politecn Torino, Lab Engn Neuromuscular Syst LISiN, Dept Elect & Telecommun, Turin, Italy
关键词
Eccentric contractions; Muscle damage; High-density surface electromyography; Ultrasound echo intensity; Neuromuscular electrical stimulation; MUSCLE DAMAGE; RELIABILITY; CONTRACTIONS; SUBSEQUENT; RECOVERY; POSITION; FORCE;
D O I
10.1007/s00421-020-04520-4
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Purpose Previous evidence from surface electromyograms (EMGs) suggests that exercise-induced muscle damage (EIMD) may manifest unevenly within the muscle. Here we investigated whether these regional changes were indeed associated with EIMD or if they were attributed to spurious factors often affecting EMGs. Methods Ten healthy male subjects performed 3 x 10 eccentric elbow flexions. Maximal voluntary contraction (MVC), muscle soreness and ultrasound images from biceps brachii distal and proximal regions were measured immediately before (baseline) and during each of the following 4 days after the exercise. Moreover, 64 monopolar surface EMGs were detected while 10 supramaximal pulses were applied to the musculocutaneous nerve. The innervation zone (IZ), the number of electrodes detecting largest M-waves and their centroid longitudinal coordinates were assessed to characterize the spatial distribution of the M-waves amplitude. Results The MVC torque decreased (similar to 25%;P < 0.001) while the perceived muscle soreness scale increased (similar to 4 cm; 0 cm for no soreness and 10 cm for highest imaginable soreness;P < 0.005) across days. The echo intensity of the ultrasound images increased at 48 h (71%), 72 h (95%) and 96 h (112%) for both muscle regions (P < 0.005), while no differences between regions were observed (P = 0.136). The IZ location did not change (P = 0.283). The number of channels detecting the greatest M-waves significantly decreased (up to 10.7%;P < 0.027) and the centroid longitudinal coordinate shifted distally at 24, 48 and 72 h after EIMD (P < 0.041). Conclusion EIMD consistently changed supramaximal M-waves that were detected mainly proximally from the biceps brachii, suggesting that EIMD takes place locally within the biceps brachii.
引用
收藏
页码:307 / 318
页数:12
相关论文
共 41 条
  • [1] APONEUROSIS LENGTH AND FASCICLE INSERTION ANGLES OF THE BICEPS BRACHII
    Asakawa, Deanna S.
    Pappas, George P.
    Drace, John E.
    Delp, Scott L.
    [J]. JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2002, 2 (3-4) : 449 - 455
  • [2] Reliability of quadriceps surface electromyography measurements is improved by two vs. single site recordings
    Balshaw, T. G.
    Fry, A.
    Maden-Wilkinson, T. M.
    Kong, P. W.
    Folland, J. P.
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2017, 117 (06) : 1085 - 1094
  • [3] Pulse charge and not waveform affects M-wave properties during progressive motor unit activation
    Botter, A.
    Merletti, R.
    Minetto, M. A.
    [J]. JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2009, 19 (04) : 564 - 573
  • [4] Botter A., 2016, SURFACE ELECTROMYOGR, P311, DOI [10.1002/9781119082934.ch11, DOI 10.1002/9781119082934.CH11]
  • [5] Reliability of the biceps brachii M-wave
    Calder K.M.
    Hall L.-A.
    Lester S.M.
    Inglis J.G.
    Gabriel D.A.
    [J]. Journal of NeuroEngineering and Rehabilitation, 2 (1) : 1 - 8
  • [6] Effect of electrode array position and subcutaneous tissue thickness on conduction velocity estimation in upper trapezius muscle
    Cescon, Corrado
    Rebecchi, Paola
    Merletti, Roberto
    [J]. JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2008, 18 (04) : 628 - 636
  • [7] Effects of set-repetition configuration in eccentric exercise on muscle damage and the repeated bout effect
    Chan, R.
    Newton, M.
    Nosaka, K.
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2012, 112 (07) : 2653 - 2661
  • [8] Effects of a second bout of maximal eccentric exercise on muscle damage and electromyographic activity
    Chen, TC
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2003, 89 (02) : 115 - 121
  • [9] CICCHETTI DV, 1981, AM J MENT DEF, V86, P127
  • [10] Texture analysis of ultrasound images is a sensitive method to follow-up muscle damage induced by eccentric exercise
    da Matta, Thiago Torres
    de Albuquerque Pereira, Wagner Coelho
    Radaelli, Regis
    Pinto, Ronei Silveira
    de Oliveira, Liliam Fernandes
    [J]. CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2018, 38 (03) : 477 - 482