Intracranial Complex Ruptured Aneurysms Coiled with Overlapping Low-Profile Visualized Intraluminal Support Stents: Another Available Option for Complex Ruptured Intracranial Aneurysms

被引:8
作者
Yan, Zhiyuan [1 ]
Zheng, Kuang [1 ]
Xiong, Ye [1 ]
Lan, Fujun [1 ]
Wang, Yunhui [1 ]
Tan, Xianxi [1 ]
Zhong, Ming [1 ]
Li, Zequn [1 ]
机构
[1] Wenzhou Med Univ, Dept Neurosurg, Affiliated Hosp 1, Wenzhou, Zhejiang, Peoples R China
关键词
Complex; Intracranial aneurysms; LVIS stents; Overlapping; Ruptured; ASSISTED COILING; ENDOVASCULAR TREATMENT; CAVERNOUS ANEURYSMS; PARENT ARTERY; SAFETY; COMPLICATIONS; EMBOLIZATION; EFFICACY; LVIS;
D O I
10.1016/j.wneu.2018.12.142
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: Overlapping stents represent a new paradigm in endovascular interventions, especially for complex and wide-necked aneurysms. The low-profile visualized intraluminal support (LVIS) device is a new generation of self-expanding braided stents recently introduced in China for stent-assisted coiling of intracranial aneurysms. We report several cases of intracranial aneurysms coiled using overlapping LVIS stents to evaluate its efficacy and safety. METHODS: Patients with ruptured intracranial aneurysms treated with double LVIS stents at our center between November 2014 and May 2016 were reviewed. The clinical data and technical results are presented. RESULTS: Ten patients with 15 aneurysms were treated with double LVIS stents, with a 100% technical success rate. No mortality was observed. Immediate angiographic outcome evaluation showed complete occlusion in 13 aneurysms (86.7%) and neck remnants in 2 aneurysms (13.3%). CONCLUSIONS: Double LVIS stents are safe and effective in the treatment of intracranial aneurysms, especially complex aneurysms.
引用
收藏
页码:E22 / E28
页数:7
相关论文
共 26 条
  • [1] Endovascular Treatment of Intracranial Aneurysms With Flow Diverters A Meta-Analysis
    Brinjikji, Waleed
    Murad, Mohammad H.
    Lanzino, Giuseppe
    Cloft, Harry J.
    Kallmes, David F.
    [J]. STROKE, 2013, 44 (02) : 442 - 447
  • [2] Coiling of Large and Giant Aneurysms: Complications and Long-Term Results of 334 Cases
    Chalouhi, N.
    Tjoumakaris, S.
    Gonzalez, L. F.
    Dumont, A. S.
    Starke, R. M.
    Hasan, D.
    Wu, C.
    Singhal, S.
    Moukarzel, L. A.
    Rosenwasser, R.
    Jabbour, P.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (03) : 546 - 552
  • [3] Stent-Assisted Coiling Versus Balloon Remodeling of Wide-Neck Aneurysms: Comparison of Angiographic Outcomes
    Chalouhi, N.
    Starke, R. M.
    Koltz, M. T.
    Jabbour, P. M.
    Tjoumakaris, S. I.
    Dumont, A. S.
    Rosenwasser, R. H.
    Singhal, S.
    Gonzalez, L. F.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (10) : 1987 - 1992
  • [4] Overlapping stents for blood blister-like aneurysms of the internal carotid artery
    Fang, Yi-Bin
    Li, Qiang
    Wu, Yi-Na
    Zhang, Qi
    Yang, Peng-Fei
    Zhao, Wen-Yuan
    Huang, Qing-Hai
    Hong, Bo
    Xu, Yi
    Liu, Jian-Min
    [J]. CLINICAL NEUROLOGY AND NEUROSURGERY, 2014, 123 : 34 - 39
  • [5] Comparison of Recanalization and In-Stent Stenosis Between the Low-Profile Visualized Intraluminal Support Stent and Enterprise Stent-Assisted Coiling for 254 Intracranial Aneurysms
    Feng, Xin
    Qian, Zenghui
    Liu, Peng
    Zhang, Baorui
    Wang, Luyao
    Guo, Erkang
    Wen, Xiaolong
    Xu, Wenjuan
    Jiang, Chuhan
    Wu, Zhongxue
    Li, Youxiang
    Liu, Aihua
    [J]. WORLD NEUROSURGERY, 2018, 109 : E99 - E104
  • [6] The safety and efficacy of low profile visualized intraluminal support (LVIS) stents in assisting coil embolization of intracranial saccular aneurysms: a single center experience
    Feng, Zhengzhe
    Fang, Yibin
    Xu, Yi
    Hong, Bo
    Zhao, Wenyuan
    Liu, Jianmin
    Huang, Qinghai
    [J]. JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2016, 8 (11) : 1192 - 1196
  • [7] Stent-Assisted Coiling versus Coiling in Treatment of Intracranial Aneurysm: A Systematic Review and MetaAnalysis
    Hong, Yuan
    Wang, Yong-Jie
    Deng, Zheng
    Wu, Qun
    Zhang, Jian-Min
    [J]. PLOS ONE, 2014, 9 (01):
  • [8] Safety and effectiveness of the Low Profile Visualized Intraluminal Support (LVIS and LVIS Jr) devices in the endovascular treatment of intracranial aneurysms: results of the TRAIL multicenter observational study
    Iosif, Christina
    Piotin, Michel
    Saleme, Suzana
    Barreau, Xavier
    Sedat, Jacques
    Chau, Yves
    Sourour, Nader
    Aggour, Mohamed
    Brunel, Herve
    Bonafe, Alain
    Machi, Paolo
    Riquelme, Carlos
    Costalat, Vincent
    Pierot, Laurent
    Blanc, Raphael
    Mounayer, Charbel
    [J]. JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2018, 10 (07) : 675 - 681
  • [9] Simple Coiling versus Stent-Assisted Coiling of Paraclinoid Aneurysms : Radiological Outcome in a Single Center Study
    Kim, Soo Yeon
    Park, Dong Sun
    Park, Hye Yin
    Chun, Young Il
    Moon, Chang Taek
    Roh, Hong Gee
    [J]. JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2017, 60 (06) : 644 - 653
  • [10] Meta-analysis of treatment outcomes of posterior circulation non-saccular aneurysms by flow diverters
    Kiyofuji, Satoshi
    Graffeo, Christopher S.
    Perry, Avital
    Murad, Mohammad Hassan
    Flemming, Kelly D.
    Lanzino, Giuseppe
    Rangel-Castilla, Leonardo
    Brinjikji, Waleed
    [J]. JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2018, 10 (05) : 500 - 506