Characteristic of thoron (220Rn) in environment

被引:35
作者
Hosoda, Masahiro [1 ]
Kudo, Hiromi [1 ]
Iwaoka, Kazuki [2 ]
Yamada, Ryohei [1 ]
Suzuki, Takahito [1 ]
Tamakuma, Yuki [1 ]
Tokonami, Shinji [2 ]
机构
[1] Hirosaki Univ, Grad Sch Hlth Sci, 66-1 Hon Cho, Hirosaki, Aomori 0368564, Japan
[2] Hirosaki Univ, Inst Radiat Emergency Med, 66-1 Hon Cho, Hirosaki, Aomori 0368564, Japan
关键词
Thoron; Passive-type radon-thoron discrimination monitor; Spatial distribution; Equilibrium factor; Dose estimation; LONG-TERM MEASUREMENTS; PROGENY CONCENTRATIONS; INDOOR RADON; DWELLINGS; AREA;
D O I
10.1016/j.apradiso.2016.11.014
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
This paper describes importance of Rn-220 (hereafter thoron) progeny measurement for the dose estimation. Although the spatial distribution of thoron activity concentration strongly depends on the distance from wall surface as an indoor thoron source), a homogeneous distribution was expected to be observed for Pb-212 activity concentration which was one of thoron progeny. Furthermore, the mean equilibrium factor for thoron obtained by the recent measurements in several cotintries widely ranged from 0.008 to 0.07. Therefore the bronchial dose evaluated using the equilibrium factor and activity concentration of thoron instead of thoron progeny activity concentration may have a large uncertainty. Thus, the thoron progeny measurement should be investigated at each measurement point for the dose estimation for thoron.
引用
收藏
页码:7 / 10
页数:4
相关论文
共 28 条
[1]  
[Anonymous], 2018, WHO HDB INDOOR RADON
[2]  
[Anonymous], 2008, REP GEN ASS SCI ANN
[3]   Characteristics of thoron and thoron progeny in Canadian homes [J].
Chen, Jing ;
Moir, Deborah ;
Sorimachi, Atsuyuki ;
Tokonami, Shinji .
RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2011, 50 (01) :85-89
[4]   Radon in homes and risk of lung cancer:: collaborative analysis of individual data from 13 European case-control studies [J].
Darby, S ;
Hill, D ;
Auvinen, A ;
Barrios-Dios, JM ;
Baysson, H ;
Bochicchio, F ;
Deo, H ;
Falk, R ;
Forastiere, F ;
Hakama, M ;
Heid, I ;
Kreienbrock, L ;
Kreuzer, M ;
Lagarde, F ;
Mäkeläinen, I ;
Muirhead, C ;
Oberaigner, W ;
Pershagen, G ;
Ruano-Ravina, A ;
Ruosteenoja, E ;
Rosario, AS ;
Tirmarche, M ;
Tomásek, L ;
Whitley, E ;
Wichmann, HE ;
Doll, R .
BMJ-BRITISH MEDICAL JOURNAL, 2005, 330 (7485) :223-226
[5]  
DOI M, 1994, HEALTH PHYS, V66, P43, DOI 10.1097/00004032-199401000-00006
[6]   Calibration of CR-39-based thoron progeny device [J].
Fabian, F. ;
Csordas, A. ;
Shahrokhi, A. ;
Somlai, J. ;
Kovacs, T. .
RADIATION PROTECTION DOSIMETRY, 2014, 160 (1-3) :169-172
[7]   FIELD EXPERIENCE ON INDOOR RADON, THORON AND THEIR PROGENIES WITH SOLID-STATE DETECTORS IN A SURVEY OF KOSOVO AND METOHIJA (BALKAN REGION) [J].
Gulan, L. ;
Milic, G. ;
Bossew, P. ;
Omori, Y. ;
Ishikawa, T. ;
Mishra, R. ;
Mayya, Y. S. ;
Stojanovska, Z. ;
Nikezic, D. ;
Vuckovic, B. ;
Zunic, Z. S. .
RADIATION PROTECTION DOSIMETRY, 2012, 152 (1-3) :189-197
[8]   Measurement of the indoor and outdoor 220Rn (thoron) equilibrium factor: application to lung dose [J].
Harley, N. ;
Chittaporn, P. ;
Medora, R. ;
Merrill, R. .
RADIATION PROTECTION DOSIMETRY, 2010, 141 (04) :357-362
[9]   Comparative analysis of radon, thoron and thoron progeny concentration measurements [J].
Janik, Miroslaw ;
Tokonami, Shinji ;
Kranrod, Chutima ;
Sorimachi, Atsuyuki ;
Ishikawa, Tetsuo ;
Hosoda, Masahiro ;
Mclaughlin, James ;
Chang, Byung-Uck ;
Kim, Yong Jae .
JOURNAL OF RADIATION RESEARCH, 2013, 54 (04) :597-610
[10]   INDOOR CONCENTRATIONS OF RN-220 AND ITS DECAY PRODUCTS [J].
KATASE, A ;
MATSUMOTO, Y ;
SAKAE, T ;
ISHIBASHI, K .
HEALTH PHYSICS, 1988, 54 (03) :283-286