Determination of Cr in water solution by laser-induced breakdown spectroscopy with different univariate calibration models

被引:23
作者
Huang, Lin [1 ]
Yao, Mingyin [1 ]
Xu, Yuan [1 ]
Liu, Muhua [1 ]
机构
[1] Jiangxi Agr Univ, Opt Elect Applicat Biomat Lab, Nanchang 330045, Jiangxi, Peoples R China
来源
APPLIED PHYSICS B-LASERS AND OPTICS | 2013年 / 111卷 / 01期
基金
中国国家自然科学基金;
关键词
TOXIC METALS; QUANTITATIVE-ANALYSIS; HEAVY-METALS; WASTE-WATER; CHROMIUM; LIQUIDS; PLANT; IONS;
D O I
10.1007/s00340-012-5305-1
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In order to prove the feasibility of laser-induced breakdown spectroscopy (LIBS) in measuring toxic metals Cr in water solution, a series of potassium bichromate standard solutions were prepared in the lab. The characteristic line intensity of Cromium (Cr) element at 357.87, 359.35, 360.53, 425.43, 427.48, and 428.97 nm was taken to build up the correlation with concentration. The indexes of relative standard deviation, intercept, slope, R (2) (coefficient of determination), and root mean square error of calibration were selected to verify the precision and accuracy of models. The comprehensive results showed that the 425.43 nm line had better superiority than other lines. And the detection limit of 6 ug/ml and repeatability of 3 % are reported. To improve the model accuracy further, the intensity ratio of single 425.43 nm line to the whole spectrum was extracted. And a linear relationship between the intensity ratio and the element Cr concentration was constructed. The results demonstrated the intensity ratio calibration had better accuracy than single line calibration, especially after smoothing. To verify the accuracy of prediction, the 100 ug/ml concentration sample was used as prediction sample. The relative error values are 13.2, 11.7, and 10.8 % for single line calibration, intensity ratio calibration with raw data, and by use of smooth processing data, respectively. The results further indicated that the intensity ratio calibration improved the accuracy of measurement than single line calibration. It is worth mentioning that the application of LIBS aiming the direct analysis of heavy metals in water is a great challenge that still needs efforts for its development and validation.
引用
收藏
页码:45 / 51
页数:7
相关论文
共 21 条
  • [1] On-line sequential injection dispersive liquid-liquid microextraction system for flame atomic absorption spectrometric determination of copper and lead in water samples
    Anthemidis, Aristidis N.
    Ioannou, Kallirroy-Ioanna G.
    [J]. TALANTA, 2009, 79 (01) : 86 - 91
  • [2] Fast quantitative determination of platinum in liquid samples by laser-induced breakdown spectroscopy
    Barreda, Flory-Anne
    Trichard, Florian
    Barbier, Sophie
    Gilon, Nicole
    Saint-Jalmes, Laurent
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 403 (09) : 2601 - 2610
  • [3] Quantitative analysis of trace metal ions in ice using laser-induced breakdown spectroscopy
    Cáceres, JO
    López, JT
    Telle, HH
    Ureña, AG
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (06) : 831 - 838
  • [4] Chitosan modified ordered mesoporous silica as micro-column packing materials for on-line flow injection-inductively coupled plasma optical emission spectrometry determination of trace heavy metals in environmental water samples
    Chen, Dahui
    Hu, Bin
    Huang, Chaozhang
    [J]. TALANTA, 2009, 78 (02) : 491 - 497
  • [5] Fast and sensitive trace metal analysis in aqueous solutions by laser-induced breakdown spectroscopy using wood slice substrates
    Chen, Zhijiang
    Li, Hongkun
    Liu, Ming
    Li, Runhua
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (01) : 64 - 68
  • [6] Quantitative analysis of toxic metals lead and cadmium in water jet by laser-induced breakdown spectroscopy
    Cheri, M. Sadegh
    Tavassoli, S. H.
    [J]. APPLIED OPTICS, 2011, 50 (09) : 1227 - 1233
  • [7] Christopher S., 2011, APPL PHYS A, V103, P1131
  • [8] Analysis of heavy metals in liquids using Laser Induced Breakdown Spectroscopy by liquid-to-solid matrix conversion
    Diaz Pace, D. M.
    D'Angelo, C. A.
    Bertuccelli, D.
    Bertuccelli, G.
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2006, 61 (08) : 929 - 933
  • [9] Detection of mercury in water by laser-induced breakdown spectroscopy with sample pre-concentration
    Fang, X.
    Ahmad, S. R.
    [J]. APPLIED PHYSICS B-LASERS AND OPTICS, 2012, 106 (02): : 453 - 456
  • [10] Evaluation of toxic metals in the industrial effluents and their segregation through peanut husk fence for pollution abatement
    Husaini, S. N.
    Zaidi, J. H.
    Matiullah
    Akram, M.
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2011, 289 (01) : 203 - 211