Realisation of a calorimetric gas sensor on polyimide foil for applications in aseptic food industry

被引:28
作者
Kirchner, Patrick [1 ,2 ]
Oberlaender, Jan [1 ]
Friedrich, Peter [3 ]
Berger, Joerg [4 ]
Rysstad, Gunnar [5 ]
Keusgen, Michael [6 ]
Schoening, Michael J. [1 ,2 ]
机构
[1] Aachen Univ Appl Sci, INB, D-52428 Julich, Germany
[2] Forschungszentrum Julich, Peter Grunberg Inst PGI 8, D-52425 Julich, Germany
[3] Aseptiksyst & Foodtechnol, D-52441 Linnich, Germany
[4] FillDesign GmbH, D-41199 Gudderath, Germany
[5] Elopak, N-3431 Spikkestad, Norway
[6] Univ Marburg, Inst Pharmaceut Chem, D-35032 Marburg, Germany
关键词
Calorimetric gas sensor; Polyimide; Hydrogen peroxide; Sterilisation process; HYDROGEN-PEROXIDE; HUMIDITY SENSORS; DECOMPOSITION; H2O2; KINETICS; ARRAY; FABRICATION; VALIDATION; MECHANISM; SUBSTRATE;
D O I
10.1016/j.snb.2011.01.032
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A calorimetric gas sensor is presented for the monitoring of vapour-phase H2O2 at elevated temperature during sterilisation processes in aseptic food industry. The sensor was built up on a flexible polyimide foil (thickness: 25 mu m) that has been chosen due to its thermal stability and low thermal conductivity. The sensor set-up consists of two temperature-sensitive platinum thin-film resistances passivated by a layer of SU-8 photo resist and catalytically activated by manganese(IV) oxide. Instead of an active heating structure, the calorimetric sensor utilises the elevated temperature of the evaporated H2O2 aerosol. In an experimental test rig, the sensor has shown a sensitivity of 4.78 degrees C/(%, v/v) in a H2O2 concentration range of 0%, v/v to 8%, v/v. Furthermore, the sensor possesses the same, unchanged sensor signal even at varied medium temperatures between 210 degrees C and 270 degrees C of the gas stream. At flow rates of the gas stream from 8 m(3)/h to 12 m(3)/h, the sensor has shown only a slightly reduced sensitivity at a low flow rate of 8 m(3)/h. The sensor characterisation demonstrates the suitability of the calorimetric gas sensor for monitoring the efficiency of industrial sterilisation processes. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:60 / 66
页数:7
相关论文
共 29 条
[1]   Polyimide membrane for micro-heated gas sensor array [J].
Aslam, M ;
Gregory, C ;
Hatfield, JV .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 103 (1-2) :153-157
[2]   Integration of MOX gas sensors on polyimide hotplates [J].
Briand, D. ;
Colin, S. ;
Courbat, J. ;
Raible, S. ;
Kappler, J. ;
de Rooij, N. F. .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 130 (01) :430-435
[3]  
Cerny G., 1992, PACKAG TECHNOL SCI, V5, P77
[4]   Micromachined infrared bolometers on flexible polyimide substrates [J].
Dayeh, SA ;
Butler, DP ;
Çelik-Butler, Z .
SENSORS AND ACTUATORS A-PHYSICAL, 2005, 118 (01) :49-56
[5]   Hydrogen peroxide decomposition on manganese oxide (pyrolusite): Kinetics, intermediates, and mechanism [J].
Do, Si-Hyun ;
Batchelor, Bill ;
Lee, Hong-Kyun ;
Kong, Sung-Ho .
CHEMOSPHERE, 2009, 75 (01) :8-12
[6]   Development of polyimide flexible tactile sensor skin [J].
Engel, J ;
Chen, J ;
Liu, C .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2003, 13 (03) :359-366
[7]   The interaction between hydrogen peroxide and metal oxides: EPR investigations [J].
Giamello, E ;
Rumori, P ;
Geobaldo, F ;
Fubini, B ;
Paganini, MC .
APPLIED MAGNETIC RESONANCE, 1996, 10 (1-3) :173-192
[8]   THERMAL CONDUCTIVITY OF SILICON + GERMANIUM FROM 3 DEGREES K TO MELTING POINT [J].
GLASSBRENNER, CJ ;
SLACK, GA .
PHYSICAL REVIEW, 1964, 134 (4A) :1058-+
[9]   Methods for preservation and extension of shelf life [J].
Gould, GW .
INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 1996, 33 (01) :51-64
[10]  
Haber F., 1935, P ROYAL SOC LONDON, VA147, P332, DOI [10.1098/rspa.1934.0221, DOI 10.1098/RSPA.1934.0221]