Cardiac dual-source computed tomography - Effect of body mass index on image quality and diagnostic accuracy

被引:30
作者
Brodoefel, Harald [1 ]
Tsiflikas, Ilias [1 ]
Burgstahler, Christof [2 ]
Reimann, Anja [1 ]
Thomas, Christoph [1 ]
Schroeder, Stephen [2 ]
Kopp, Andreas F. [1 ]
Claussen, Claus D. [1 ]
Heuschmid, Martin [1 ]
机构
[1] Univ Tubingen, Dept Diagnost Radiol, D-72076 Tubingen, Germany
[2] Univ Tubingen, Dept Radiol, D-72076 Tubingen, Germany
关键词
dual-source computed tomography; coronary artery disease; obesity; image quality; diagnostic accuracy;
D O I
10.1097/RLI.0b013e318180bae1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The aim of our study was to assess the impact of body mass index (BMI) on image quality and diagnostic accuracy using dual-source computed tomography. Subjects and Methods: Dual-source computed tomography and invasive coronary angiography were performed in 125 consecutive patients. Coronary segments were assessed for both image quality (1: excellent; 4: poor) and presence of significant vessel stenosis (>= 50%). Accuracy of lesion detection was calculated using invasive coronary angiography as the standard of reference. The impact of BMI on image quality and accuracy was assessed by multivariate regression and between subgroups of BMI. Results: Mean BMI in our study was 28.4 +/- 4.1 kg/m(2). In multivariate regression, BMI was proved to have a significant and independent impact on image quality (P = 0.009). Similarly, the latter was significantly degraded in a subgroup of patients with BMI >= 30 kg/m(2) (P < 0.05). Although the proportion of segments with diagnostic image quality was equal in all BMI subgroups, linear regression suggested 25 kg/m(2) as the cut-off until which excellent or good image quality can be achieved. Sensitivity, specificity, positive, and negative predictive values were 91.6%, 93%, 75.2%, and 97.9% on a per-segment and 100%, 77.5%, 90.4%, and 100% on a per-patient level. In both multivariate analysis and comparison of subgroups, there was no significant effect of BMI on the per-segment diagnostic accuracy. Conclusion: Although in an unselected population, obesity turns out to have an independent impact on image quality, there is no translation of this effect into a deterioration of diagnostic accuracy.
引用
收藏
页码:712 / 718
页数:7
相关论文
共 25 条
[1]   Contrast-enhanced coronary artery visualization by dual-source computed tomography - Initial experience [J].
Achenbach, S ;
Ropers, D ;
Kuettner, A ;
Flohr, T ;
Ohnesorge, B ;
Bruder, H ;
Theessen, H ;
Karakaya, M ;
Daniel, WG ;
Bautz, W ;
Kalender, WA ;
Anders, K .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 57 (03) :331-335
[2]   American College of Cardiology/Society for Cardiac Angiography and Interventions clinical expert consensus document on Cardiac Catheterization Laboratory standards - A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents [J].
Bashore, TM ;
Bates, ER ;
Berger, PB ;
Clark, DA ;
Cusma, JT ;
Dehmer, GJ ;
Kern, MJ ;
Laskey, WK ;
O'Laughlin, MP ;
Oesterle, S ;
Popma, JJ ;
O'Rourke, RA ;
Abrams, J ;
Bates, ER ;
Brodie, BR ;
Douglas, PS ;
Gregoratos, G ;
Hlatky, MA ;
Hochman, JS ;
Kaul, S ;
Tracy, CM ;
Waters, DD ;
Winters, WL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (08) :2170-2214
[3]   Assessment of global left and right ventricular function using dual-source computed tomography (DSCT) in comparison to MRI -: An experimental study in a porcine model [J].
Bruners, Philipp ;
Mahnken, Andreas H. ;
Knackstedt, Christian ;
Lithmann, Nadja ;
Spuentrup, Ehnar ;
Das, Marco ;
Hohl, Christian ;
Wildberger, Joachim E. ;
Schmitz-Rode, Thomas ;
Guenther, Rolf W. ;
Muehlenbruch, Georg .
INVESTIGATIVE RADIOLOGY, 2007, 42 (11) :756-764
[4]   Image quality and diagnostic accuracy of 16-slice multidetector computed tomography for the detection of coronary artery disease in obese patients [J].
Burgstahler, C ;
Beck, T ;
Kuettner, A ;
Reimann, A ;
Kopp, AF ;
Heuschmid, M ;
Claussen, CD ;
Schroeder, S .
INTERNATIONAL JOURNAL OF OBESITY, 2006, 30 (03) :569-573
[5]   First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268
[6]   Obesity [J].
Haslam, DW ;
James, WPT .
LANCET, 2005, 366 (9492) :1197-1209
[7]   ACCF/ACR/SCCT/SCMR/ASNC/NASCI/SCAI/SIR 2006 appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging - A report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group, American College of Radiology, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, American Society of Nuclear Cardiology, North American Society for Cardiac Imaging, Society for Cardiovascular Angiography and Interventions, and Society of Interventional Radiology [J].
Hendel, Robert C. ;
Patel, Manesh R. ;
Kramer, Christopher M. ;
Poon, Michael ;
Hendel, Robert C. ;
Brindis, Ralph G. ;
Hendel, Robert C. ;
Douglas, Pamela S. ;
Peterson, Eric D. ;
Wolk, Michael J. ;
Allen, Joseph M. ;
Patel, Manesh R. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (07) :1475-1497
[8]   Usefulness of noninvasive cardiac imaging using dual-source computed tomography in an unselected population with high prevalence of coronary artery disease [J].
Heuschmid, Martin ;
Burgstahler, Christof ;
Reimann, Ania ;
Brodoefel, Harald ;
Mysal, Ines ;
Haeberle, Ellen ;
Tsiflikas, Ilijas ;
Claussen, Claus D. ;
Kopp, Andreas F. ;
Schroeder, Stephen .
AMERICAN JOURNAL OF CARDIOLOGY, 2007, 100 (04) :587-592
[9]   Diagnostic accuracy of dual-source computed tomography in the diagnosis of coronary artery disease [J].
Johnson, Thorsten R. C. ;
Nikolaou, Konstantin ;
Busch, Stephanie ;
Leber, Alexander W. ;
Becker, Alexander ;
Wintersperger, Bernd J. ;
Rist, Carsten ;
Knez, Andreas ;
Reiser, Maximilian F. ;
Becker, Christoph R. .
INVESTIGATIVE RADIOLOGY, 2007, 42 (10) :684-691
[10]   Dual-source CT cardiac imaging: initial experience [J].
Johnson, Thorsten R. C. ;
Nikolaou, Konstantin ;
Wintersperger, Bernd J. ;
Leber, Alexander W. ;
von Ziegler, Franz ;
Rist, Carsten ;
Buhmann, Sonja ;
Knez, Andreas ;
Reiser, Maximilian F. ;
Becker, Christoph R. .
EUROPEAN RADIOLOGY, 2006, 16 (07) :1409-1415