A Comparison of Different Techniques for Induction Motor Rotor Fault Diagnosis

被引:26
作者
Alwodai, A. [1 ]
Gu, F. [1 ]
Ball, A. D. [1 ]
机构
[1] Univ Huddersfield, Ctr Diagnost Engn, Huddersfield HD1 3DH, W Yorkshire, England
来源
25TH INTERNATIONAL CONGRESS ON CONDITION MONITORING AND DIAGNOSTIC ENGINEERING (COMADEM 2012) | 2012年 / 364卷
关键词
Induction motor; Broken bar; Motor current signature analysis; Vibration; Instantaneous angular speed (IAS); Power spectrum; CURRENT SIGNATURE ANALYSIS; STATOR CURRENT; VIBRATION; SPEED;
D O I
10.1088/1742-6596/364/1/012066
中图分类号
O59 [应用物理学];
学科分类号
摘要
The problem of failures in induction motors is a large concern due to its significant influence over industrial production. Therefore a large number of detection techniques were presented to avoid this problem. This paper presents the comparison results of induction motor rotor fault detection using three methods: motor current signature analysis (MCSA), surface vibration (SV), and instantaneous angular speed (IAS). These three measurements were performed under different loads with three rotor conditions: baseline, one rotor bar broken and two rotor bar broken. The faults can be detected and diagnosed based on the amplitude difference of the characteristic frequency components of power spectrum. However IAS may be the best technique because it gives the clearest spectrum representation in which the largest amplitude change is observed due to the faults.
引用
收藏
页数:11
相关论文
共 21 条
[1]  
Alwodai A, 2011, MOT CURR SIGN AN VAR, P884
[2]   Quantitative evaluation of induction motor broken bars by means of electrical signature analysis [J].
Bellini, A ;
Filippetti, F ;
Franceschini, G ;
Tassoni, C ;
Kliman, GB .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2001, 37 (05) :1248-1255
[3]   A validated model for the prediction of rotor bar failure in squirrel-cage motors using instantaneous angular speed [J].
Ben Sasi, Ahmed Y. ;
Gu, Fengshou ;
Li, Yuhua ;
Ball, Andrew D. .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2006, 20 (07) :1572-1589
[4]   A review of induction motors signature analysis as a medium for faults detection [J].
Benbouzid, ME .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2000, 47 (05) :984-993
[5]   What stator current processing-based technique to use for induction motor rotor faults diagnosis? [J].
Benbouzid, MEH ;
Kliman, GB .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2003, 18 (02) :238-244
[6]   Induction motor asymmetrical faults detection using advanced signal processing techniques [J].
Benbouzid, MEH ;
Nejjari, H ;
Beguenane, R ;
Vieira, M .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1999, 14 (02) :147-152
[7]   A DSP-based FFT-analyzer for the fault diagnosis of rotating machine based on vibration analysis [J].
Betta, G ;
Liguori, C ;
Paolillo, A ;
Pietrosanto, A .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2002, 51 (06) :1316-1322
[8]   AI techniques in induction machines diagnosis including the speed ripple effect [J].
Filippetti, F ;
Franceschini, G ;
Tassoni, C ;
Vas, P .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1998, 34 (01) :98-108
[9]   Detection of induction motor faults: A comparison of stator current, vibration and acoustic methods [J].
Li, WD ;
Mechefske, CK .
JOURNAL OF VIBRATION AND CONTROL, 2006, 12 (02) :165-188
[10]   The measurement of instantaneous angular speed [J].
Li, YH ;
Gu, FS ;
Harris, G ;
Ball, A ;
Bennett, N ;
Travis, K .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2005, 19 (04) :786-805