Sample patterning on NMR surface microcoils

被引:24
作者
Ehrmann, K [1 ]
Gersbach, M
Pascoal, P
Vincent, F
Massin, C
Stamou, D
Besse, PA
Vogel, H
Popovic, RS
机构
[1] Ecole Polytech Fed Lausanne, Inst Microsyst, CH-1015 Lausanne, Switzerland
[2] Ecole Polytech Fed Lausanne, Inst Chem Engn, CH-1015 Lausanne, Switzerland
[3] Univ Copenhagen, Nanosci Ctr, Bionanotechnol Lab, DK-2100 Copenhagen, Denmark
关键词
planar surface microcoil; B-1; homogeneity; signal-to-noise ratio; lipid vesicles; aligned microcontact printing;
D O I
10.1016/j.jmr.2005.08.018
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Aligned microcontact printing for patterning the sample in areas of homogeneous RF-field on the highly sensitive surface of planar NMR microprobes is presented. We experimentally demonstrate that sample patterning allows drastic improvement of the spin excitation uniformity. The NMR microprobes are designed for cell analysis and characterized using lipid vesicles as cell substitutes. Lipid vesicles are advantageous as composition and concentration of the confined solution are precisely controlled and because of their similarity to living cells. Using aligned microcontact printing, a monolayer of lipid vesicles is immobilized on the surface of the planar NMR microprobe in a patterned way. H-1 NMR spectra and CPMG spin echoes of sucrose solution confined within the lipid vesicles are successfully recorded. Nutation curves of the sample structured in different patterns demonstrate the impact of patterning on the spin excitation uniformity. The total detection volumes are between 1 and 2 nL and derived with help of a theoretic model based on 3D finite element simulation. This model predicts the signal-to-noise ratio and the progression of the nutation curves. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:96 / 105
页数:10
相关论文
共 25 条
[1]   Microfluidic devices for cellomics: a review [J].
Andersson, H ;
van den Berg, A .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 92 (03) :315-325
[2]  
[Anonymous], 2003, ANGEW CHEM
[3]  
Bosch C. S., 1992, NMR-BASIC PRINC PROG, V27, P3, DOI [10.1007/978-3-642-77208-5_1, DOI 10.1007/978-3-642-77208-5_1]
[4]  
Callaghan P.T., 1991, Principles of nuclear magnetic resonance microscopy, V1st
[5]   Chemical transformations in individual ultrasmall biomimetic containers [J].
Chiu, DT ;
Wilson, CF ;
Ryttsén, F ;
Strömberg, A ;
Farre, C ;
Karlsson, A ;
Nordholm, S ;
Gaggar, A ;
Modi, BP ;
Moscho, A ;
Garza-López, RA ;
Orwar, O ;
Zare, RN .
SCIENCE, 1999, 283 (5409) :1892-1895
[6]   NMR spiral surface microcoils: Design, fabrication, and imaging [J].
Eroglu, S ;
Gimi, B ;
Roman, B ;
Friedman, G ;
Magin, RL .
CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2003, 17B (01) :1-10
[7]   NMR spiral surface microcoils: Applications [J].
Gimi, B ;
Eroglu, S ;
Leoni, L ;
Desai, TA ;
Magin, RL ;
Roman, BB .
CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2003, 18B (01) :1-8
[8]  
GUPTA RK, 1987, NMR SPECTROSCOPY CEL
[9]   Experimental models of primitive cellular compartments: Encapsulation, growth, and division [J].
Hanczyc, MM ;
Fujikawa, SM ;
Szostak, JW .
SCIENCE, 2003, 302 (5645) :618-622
[10]   SIGNAL-TO-NOISE RATIO OF NUCLEAR MAGNETIC-RESONANCE EXPERIMENT [J].
HOULT, DI ;
RICHARDS, RE .
JOURNAL OF MAGNETIC RESONANCE, 1976, 24 (01) :71-85