Building materials. VOC emissions, diffusion behaviour and implications from their use

被引:25
作者
Katsoyiannis, Athanasios [1 ]
Leva, Paolo [1 ]
Barrero-Moreno, Josefa [1 ]
Kotzias, Dimitrios [1 ]
机构
[1] Commiss European Communities, Joint Res Ctr, IHCP, Chem Assessment & Testing Unit, I-21020 Ispra, VA, Italy
关键词
VOCs; Neopentylglycol; Emission test; Environmental chamber; Building materials; VOLATILE ORGANIC-COMPOUNDS; COEFFICIENTS;
D O I
10.1016/j.envpol.2012.04.030
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Five cement- and five lime-based building materials were examined in an environmental chamber for their emissions of Volatile Organic Compounds (VOCs). Typical VOCs were below detection limits, whereas not routinely analysed VOCs, like neopentyl glycol (NPG), dominated the cement-based products emissions, where, after 72 h, it was found to occur, in levels as high as 1400 mu g m(-3), accounting for up to 93% of total VOCs. The concentrations of NPG were not considerably changed between the 24 and 72 h of sampling. The permeability of building materials was assessed through experiments with a dual environmental chamber; it was shown that building materials facilitate the diffusion of chemicals through their pores, reaching equilibrium relatively fast (6 h). (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:230 / 234
页数:5
相关论文
共 20 条
  • [11] VOC and carbonyl emissions from carpets: A comparative study using four types of environmental chambers
    Katsoyiannis, Athanasios
    Leva, Paolo
    Kotzias, Dirnitrios
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2008, 152 (02) : 669 - 676
  • [12] Kotzias D, 2004, FRESEN ENVIRON BULL, V13, P1536
  • [13] Evaluation of the fate of the active ingredients of insecticide sprays used indoors
    Leva, Paolo
    Katsoyiannis, Athanasios
    Barrero-Morero, Josefa
    Kephalopoulos, Stylianos
    Kotzias, Dimitrios
    [J]. JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART B-PESTICIDES FOOD CONTAMINANTS AND AGRICULTURAL WASTES, 2009, 44 (01) : 51 - 57
  • [14] Molhave L., 1990, INDOOR AIR 90 PROC 5, V5, P15
  • [15] OECD, OECD PUBL NEOP GLYC
  • [16] Organic air pollutants inside and outside residences in Shimizu, Japan: Levels, sources and risks
    Ohura, Takeshi
    Amagai, Takashi
    Senga, Yoshinori
    Fusaya, Masahiro
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2006, 366 (2-3) : 485 - 499
  • [17] Exposure to major volatile organic compounds and carbonyls in European indoor environments and associated health risk
    Sarigiannis, Dimosthenis A.
    Karakitsios, Spyros P.
    Gotti, Alberto
    Liakos, Ioannis L.
    Katsoyiannis, Athanasios
    [J]. ENVIRONMENT INTERNATIONAL, 2011, 37 (04) : 743 - 765
  • [18] Seifert B., 1990, PROC 5 INT C INDOOR, V5, P35
  • [19] Ultra-fine particles release from hardcopy devices: Sources, real-room measurements and efficiency of filter accessories
    Wensing, Michael
    Schripp, Tobias
    Uhde, Erik
    Salthammer, Tunga
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2008, 407 (01) : 418 - 427
  • [20] An experimental study of relative humidity effect on VOCs' effective diffusion coefficient and partition coefficient in a porous medium
    Xu, Jing
    Zhang, Jianshun S.
    [J]. BUILDING AND ENVIRONMENT, 2011, 46 (09) : 1785 - 1796