Resolution of negative dysphotopsia after laser anterior capsulotomy

被引:29
作者
Cooke, David L. [1 ]
Kasko, Susan [2 ]
Platt, Lucas O. [1 ]
机构
[1] Great Lakes Eye Care, St Joseph, MI 49085 USA
[2] Michigan State Univ, Coll Osteopath Med, E Lansing, MI 48824 USA
关键词
INTRAOCULAR-LENS; IMPLANTATION; SYMPTOMS; ETIOLOGY;
D O I
10.1016/j.jcrs.2013.05.002
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
It has been suggested that a clear anterior nasal capsule contributes to negative dysphotopsia and that symptoms may resolve with opacification of the capsule. We describe a case in which negative dysphotopsia occurred despite a translucent anterior peripheral capsule and resolved following laser removal of the anterior nasal capsule. (C) 2013 ASCRS and ESCRS
引用
收藏
页码:1107 / 1109
页数:3
相关论文
共 10 条
[1]   Positive and negative dysphotopsia in patients with acrylic intraocular lenses [J].
Davison, JA .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (09) :1346-1355
[2]   Optical phenomena causing negative dysphotopsia [J].
Gosala, Seshubabu .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (09) :1620-1620
[3]  
Holladay JT, 2013, J CATARACT REFR SURG, V39, P486
[4]   Negative dysphotopsia: The enigmatic penumbra [J].
Holladay, Jack T. ;
Zhao, Huawei ;
Reisin, Carina R. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (07) :1251-1265
[5]  
Holladay JT, 2013, J CATARACT REFR SURG, V39, P1123
[6]   Pseudophakic negative dysphotopsia: Surgical management and new theory of etiology [J].
Masket, Samuel ;
Fram, Nicole R. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (07) :1199-1207
[7]   Negative dysphotopsia associated with implantation of the Z9000 intraocular lens [J].
Narváez, J ;
Banning, CS ;
Stulting, D .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (04) :846-847
[8]   Negative dysphotopsia: Long-term study and possible explanation for transient symptoms [J].
Osher, Robert H. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (10) :1699-1707
[9]   Negative dysphotopsia after intraocular lens implantation irrespective of design and material [J].
Trattler, WB ;
Whitsett, JC ;
Simone, PA .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (04) :841-845
[10]   Intraocular lens exchange in patients with negative dysphotopsia symptoms [J].
Vamosi, Peter ;
Csakany, Bela ;
Nemeth, Janos .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (03) :418-424