Identification and localization of incipient intermittent inter-turn fault in the stator of a three phase permanent magnet synchronous motor

被引:0
|
作者
Obeid, Najla Haje [1 ]
Battiston, Alexandre [1 ]
Boileau, Thierry [2 ]
Nahid-Mobarakeh, Babak [2 ]
机构
[1] IFP Energies Nouvelles, Rueil Malmaison, Mecatron & Numer Dept, Rueil Malmaison, France
[2] Lorraine Univ, GREEN Lab, Lorraine, France
关键词
adapted wavelet; fault detection; fault localization; incipient fault; intermittent fault; inter-turn fault;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper discusses the detection and the localization of incipient intermittent fault in the stator winding. The study is applied to a permanent magnet synchronous motor. The detection method uses the fault signature to identify its presence and then it uses the phase to phase voltages to localize the phase containing the defected turns. The theoretical and the experimental results show the effectiveness of the method.
引用
收藏
页码:173 / 180
页数:8
相关论文
共 50 条
  • [1] Modeling and Diagnostic of Incipient Inter-turn Faults for a Three Phase Permanent Magnet Synchronous Motor Using Wavelet Transform
    Obeid, Najla Haje
    Boileau, Thierry
    Nahid-Mobarakeh, Babak
    2015 51ST IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, 2015,
  • [2] Detection and Analysis of Stator Winding Inter-Turn Short Circuit Fault in Permanent Magnet Linear Synchronous Motor
    Gao, Caixia
    Hao, Chen
    Zhao, Yuebing
    OPTICAL, ELECTRONIC MATERIALS AND APPLICATIONS II, 2012, 529 : 322 - +
  • [3] Research on modeling and fault diagnosis of inter-turn short fault of permanent magnet synchronous motor
    Hu, Hongqian
    Shi, Weifeng
    Venditti, Benjamin
    JOURNAL OF COMPUTATIONAL METHODS IN SCIENCES AND ENGINEERING, 2020, 20 (03) : 959 - 973
  • [4] Inter-Turn Stator Winding fault Diagnosis for Permanent Magnet Synchronous Motor based Power Spectral Density Estimators
    Zerdani, Sara
    El Hafyani, Mohammed Larbi
    Zouggar, Smail
    2020 8TH INTERNATIONAL CONFERENCE ON SMART GRID AND CLEAN ENERGY TECHNOLOGIES (ICSGCE 2020), 2020, : 137 - 142
  • [5] Inter-turn Fault Identification of Surface-Mounted Permanent Magnet Synchronous Motor Based on Inverter Harmonics
    Gao, Fengyang
    Zhang, Guoheng
    Li, Mingming
    Gao, Yunbo
    Zhuang, Shengxian
    ENERGIES, 2020, 13 (04)
  • [6] Study on the offline inter-turn fault diagnosis according to the parameter of permanent magnet synchronous motor
    Kim H.
    Park Y.
    Oh S.-T.
    Jang H.
    Bae J.-N.
    Lee J.
    Transactions of the Korean Institute of Electrical Engineers, 2020, 69 (10): : 1456 - 1463
  • [7] Thermal Field Analysis on Inter-Turn Short Circuit Fault of Permanent Magnet Synchronous Motor
    Xie Y.
    Hu S.
    Chen P.
    Ma Z.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2022, 37 (02): : 322 - 331
  • [8] Fault-tolerant torque control of a three-phase permanent magnet synchronous motor with inter-turn winding short circuit
    Forstner, G.
    Kugi, A.
    Kemmetmüller, W.
    Control Engineering Practice, 2021, 113
  • [9] Fault-tolerant torque control of a three-phase permanent magnet synchronous motor with inter-turn winding short circuit
    Forstner, G.
    Kugi, A.
    Kemmetmueller, W.
    CONTROL ENGINEERING PRACTICE, 2021, 113
  • [10] Modelling and simulation of stator winding inter-turn faults in permanent magnet synchronous motors
    Farooq, Jawad Ahmed
    Raminosoa, Tsarafidy
    Djerdir, Abdesslem
    Miraoui, Abdellatif
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2008, 27 (04) : 887 - 896