3-D Field Mapping and Active Shimming of a Screening-Current-Induced Field in an HTS Coil Using Harmonic Analysis for High-Resolution NMR Magnets

被引:20
作者
Ahn, Min Cheol [1 ]
Hahn, Seungyong [2 ]
Lee, Haigun [3 ]
机构
[1] Kunsan Natl Univ, Dept Elect Engn, Gunsan, Jeonbuk, South Korea
[2] MIT, Francis Bitter Magnet Lab, Cambridge, MA 02139 USA
[3] Korea Univ, Dept Mat Sci & Engn, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
Active shimming; harmonic analysis; screening-current-induced field; 3-D field mapping;
D O I
10.1109/TASC.2012.2237491
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A screening-current-induced field (SCF) in a superconducting magnet is now considered as one of the major technical challenges for HTS (high-temperature superconducting) magnets, particularly wound with tape-shape conductors such as Bi2223 and YBCO, to be used for NMR (nuclear magnetic resonance) applications where a ppb (part-per-billion) level of field homogeneity is required. To date, many attempts to characterize the SCF and minimize its impact on field homogeneity have been undertaken, but it is still one of bottlenecks for HTS NMR magnets. In general, magnetic fields generated by an NMR magnet are expressed by the spatial harmonics in order to systematically characterize the field errors and obtain a target field homogeneity by shimming. Thus, it is important to analyze the spatial harmonics of the SCF in an HTS magnet for its application to a high-resolution NMR device. In this paper, magnetic fields of an HTS coil were measured within a target space using an in-house 3-D field mapper, and their spatial harmonics were obtained using associated Legendre equations. Also, the temporal behavior of the SCF was investigated by continuous field mappings and their analyses. Finally, a radial shim coil, ZY, was designed, constructed, and operated with the HTS test coil, and the hysteresis and the temporal behavior of the SCF during shimming were also studied. With a shim coil current, the ZY gradient of the SCF was reduced by 70%.
引用
收藏
页数:4
相关论文
共 9 条
[1]   Spatial and Temporal Variations of a Screening Current Induced Magnetic Field in a Double-Pancake HTS Insert of an LTS/HTS NMR Magnet [J].
Ahn, Min Cheol ;
Yagai, Tsuyoshi ;
Hahn, Seungyong ;
Ando, Ryuya ;
Bascunan, Juan ;
Iwasa, Yukikazu .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2009, 19 (03) :2269-2272
[2]   On the 600 MHz HTS Insert for a 1.3 GHz NMR Magnet [J].
Bascunan, Juan ;
Hahn, Seungyong ;
Park, Dong Keun ;
Kim, Youngjae ;
Iwasa, Yukikazu .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2012, 22 (03)
[3]   Measurement and calculation of residual magnetic field in a Bi2223/Ag magnet [J].
Gu, Chen ;
Qu, Timing ;
Han, Zhenghe .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2007, 17 (02) :2394-2397
[4]   Field mapping, NMR lineshape, and screening currents induced field analyses for homogeneity improvement in LTS/HTS NMR magnets [J].
Hahn, Seung-yong ;
Bascunan, Juan ;
Kim, Woo-Seok ;
Bobrov, Emanuel S. ;
Lee, Haigun ;
Iwasa, Yukikazu .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2008, 18 (02) :856-859
[5]   Nonlinear Behavior of a Shim Coil in an LTS/HTS NMR Magnet With an HTS Insert Comprising Double-Pancake HTS-Tape Coils [J].
Hahn, Seung-yong ;
Ahn, Min Cheol ;
Bascunan, Juan ;
Yao, Weijun ;
Iwasa, Yukikazu .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2009, 19 (03) :2285-2288
[6]   Operation and performance analyses of 350 and 700 MHz low-/high-temperature superconductor nuclear magnetic resonance magnets: A march toward operating frequencies above 1 GHz [J].
Hahn, Seungyong ;
Bascunan, Juan ;
Lee, Haigun ;
Bobrov, Emanuel S. ;
Kim, Wooseok ;
Ahn, Min Cheol ;
Iwasa, Yukikazu .
JOURNAL OF APPLIED PHYSICS, 2009, 105 (02)
[7]   Towards beyond 1 GHz NMR: Mechanism of the long-term drift of screening current-induced magnetic field in a Bi-2223 coil [J].
Koyama, Y. ;
Takao, T. ;
Yanagisawa, Y. ;
Nakagome, H. ;
Hamada, M. ;
Kiyoshi, T. ;
Takahashi, M. ;
Maeda, H. .
PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2009, 469 (13) :694-701
[8]   Perspective on a superconducting 30 T/1.3 GHz NMR spectrometer magnet [J].
Markiewicz, W. Denis ;
Miller, John R. ;
Schwartz, Justin ;
Trociewitz, Ulf P. ;
Weijers, Huub W. .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2006, 16 (02) :1523-1526
[9]   Magnitude of the Screening Field for YBCO Coils [J].
Yanagisawa, Y. ;
Kominato, Y. ;
Nakagome, H. ;
Hu, R. ;
Takematsu, T. ;
Takao, T. ;
Uglietti, D. ;
Kiyoshi, T. ;
Takahashi, M. ;
Maeda, H. .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (03) :1640-1643