Indoor air quality investigation according to age of the school buildings in Korea

被引:168
作者
Yang, Wonho [1 ]
Sohn, Jongryeul [2 ]
Kim, Jihwan [2 ]
Son, Busoon [3 ]
Park, Jinchul [4 ]
机构
[1] Catholic Univ Daegu, Dept Occupat Hlth, Gyongsan 712702, Kyongbuk, South Korea
[2] Korea Univ, Dept Environm Hlth, Seoul, South Korea
[3] Soonchunhyang Univ, Dept Environm Hlth, Chungnam, South Korea
[4] Chung Ang Univ, Sch Architecture, Seoul, South Korea
关键词
School; Indoor air quality; Season; New construction; VOLATILE ORGANIC-COMPOUNDS; OUTDOOR AIR; EXPOSURE; PREVALENCE;
D O I
10.1016/j.jenvman.2007.10.003
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Since the majority of schools are housed in buildings dating from the 1960s and 1970s, a comprehensive construction and renovation program of school buildings has been carried Out to improve the educational conditions in Korea. However, classrooms and computer rooms, with pressed wood desks, chairs and furnishings, as well as construction materials, might have negative effects on the indoor air quality. Furthermore, most schools have naturally ventilated classrooms. The purpose of this study was to characterize the concentrations of different indoor air pollutants within Korean schools and to compare their indoor levels within schools according to the age of school buildings. Indoor and outdoor air samples of carbon monoxide (CO), carbon dioxide (M), particulate matter (PM10), total microbial count (TBC), total volatile organic compounds (TVOCs) and formaldehyde (HCHO) were obtained during summer, autumn and winter from three sites a classroom, a laboratory and a computer classroom at 55 different schools. The selection of the schools was based on the number of years since the schools had been constructed. The problems causing indoor air pollution at the schools were chemicals emitted by building materials or furnishings, and insufficient ventilation rates. The I/O ratio for HCHO was 6.32 during the autumn, and the indoor HCHO concentrations (mean = 0.16 ppm) in schools constructed within I year were significantly higher than the Korean Indoor Air Standard, indicating that schools have indoor sources of HCHO. Therefore, increasing the ventilation rate by means of a mechanical system and the use of low-emission furnishings can play key roles in improving the indoor air quality within schools. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:348 / 354
页数:7
相关论文
共 19 条
[1]  
[Anonymous], 2004, 6212004 ASHRAE
[2]   Indoor and outdoor concentrations of RSP, NO2 and selected volatile organic compounds at 32 shoe stalls located near busy roadways in Seoul, Korea [J].
Bae, H ;
Yang, WH ;
Chung, MH .
SCIENCE OF THE TOTAL ENVIRONMENT, 2004, 323 (1-3) :99-105
[3]  
DALLY KA, 1981, ARCH ENVIRON HEALTH, V36, P277, DOI 10.1080/00039896.1981.10667638
[4]   Particulate matter in the indoor air of classrooms -: exploratory results from Munich and surrounding area [J].
Fromme, H. ;
Twardella, D. ;
Dietrich, S. ;
Heitmann, D. ;
Schierl, R. ;
Liebl, B. ;
Rueden, H. .
ATMOSPHERIC ENVIRONMENT, 2007, 41 (04) :854-866
[5]  
Gusten J., 1995, AIR INFILTRATION REV, V16, P5
[6]   Indoor and outdoor bioaerosol levels at recreation facilities, elementary schools, and homes [J].
Jo, WK ;
Seo, YJ .
CHEMOSPHERE, 2005, 61 (11) :1570-1579
[7]   Indoor air quality and health [J].
Jones, AP .
ATMOSPHERIC ENVIRONMENT, 1999, 33 (28) :4535-4564
[8]   Respiratory symptoms, asthma and allergen levels in schools -: comparison between Korea and Sweden [J].
Kim, J. L. ;
Elfman, L. ;
Norbaeck, D. .
INDOOR AIR, 2007, 17 (02) :122-129
[9]   The National Human Activity Pattern Survey (NHAPS): a resource for assessing exposure to environmental pollutants [J].
Klepeis, NE ;
Nelson, WC ;
Ott, WR ;
Robinson, JP ;
Tsang, AM ;
Switzer, P ;
Behar, JV ;
Hern, SC ;
Engelmann, WH .
JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 2001, 11 (03) :231-252
[10]   Indoor air and human exposure assessment - needs and approaches [J].
Kotzias, D .
EXPERIMENTAL AND TOXICOLOGIC PATHOLOGY, 2005, 57 :5-7