Intercomparison exercise on external gamma dose rate under field conditions at the laboratory of natural radiation (Saelices el Chico, Spain)

被引:16
作者
Gutierrez-Villanueva, J. L. [1 ]
Sainz-Fernandez, C. [1 ]
Fuente-Merino, I. [1 ]
Saez-Vergara, J. C. [2 ]
Correa-Garces, E. [2 ]
Quindos-Poncela, L. S. [1 ]
机构
[1] Univ Cantabria, Fac Med, RADON Grp, Santander 39011, Spain
[2] CIEMAT, Ctr Invest Energet Medioambientales & Tecnol, Environm Radiol Restorat Programme, E-28040 Madrid, Spain
关键词
ENVIRONMENTAL RADIATION;
D O I
10.1093/rpd/nct016
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The last nuclear accident in Fukushima nuclear power plant has increased the necessity for measuring radiation in the environment. Therefore, radiation monitors providing results traceable throughout the country become essential and it is very important to test them under the same environmental conditions. The first intercomparison of natural radioactivity under field conditions was held in Saelices el Chico (Salamanca, Spain) in May 2011, including an exercise on environmental dose rate. This article presents the results achieved by 19 instruments belonging to 12 institutions from 7 different countries. The tested detectors are proportional counters, ionisation chambers, GeigerMller and scintillators measuring dose rate in three stations with reference values from 110 to 1800 nGy h(1). All the results were given in terms of air kerma (nGy h(1)) and the measurements show agreement within 25 in all the sites. Evaluation criteria based on accuracy and statistical uncertainty were also carried out and 25 of participants passed the test in all sites.
引用
收藏
页码:459 / 466
页数:8
相关论文
共 13 条
[1]  
European Commission, 1996, OFFICIAL J EC L, V39
[2]   The time variation of dose rate artificially increased by the Fukushima nuclear crisis [J].
Hosoda, Masahiro ;
Tokonami, Shinji ;
Sorimachi, Atsuyuki ;
Monzen, Satoru ;
Osanai, Minoru ;
Yamada, Masatoshi ;
Kashiwakura, Ikuo ;
Akiba, Suminori .
SCIENTIFIC REPORTS, 2011, 1
[3]  
ICRU, 1994, International Commission on Radiation Units and Measurements (ICRU) Report, V53
[4]  
International Atomic Energy Agency, 2010, IAEA AN QUAL NUCL AP, V15
[5]  
International Commission on Radiological Protection, 1987, ANN ICRP, V17
[6]  
International Commission Radiological Units, 1992, J ICRU OS
[7]   The second EURADOS intercomparison of national network systems used to provide early warning of a nuclear accident [J].
Saez-Vergara, J. C. ;
Thompson, I. M. G. ;
Gurriaran, R. ;
Dombrowski, H. ;
Funck, E. ;
Neumaier, S. .
RADIATION PROTECTION DOSIMETRY, 2007, 123 (02) :190-208
[8]  
Thompson I. M. G., 1999, 106 EC EURADOS WORK
[10]   An international intercomparison of national network systems used to provide early warning of a nuclear accident having transboundary implications [J].
Thompson, IMG ;
Andersen, CE ;
Botter-Jensen, L ;
Funck, E ;
Neumaier, S ;
Sáez-Vergara, JC .
RADIATION PROTECTION DOSIMETRY, 2000, 92 (1-3) :89-100