Influence of automated visual field testing on intraocular pressure

被引:1
作者
Bertaud, Samuel [1 ]
Skarbek Borowski, Elisabeth [1 ]
Abbas, Rachid [2 ,3 ]
Baudouin, Christophe [1 ,4 ,5 ]
Labbe, Antoine [1 ,4 ,5 ]
机构
[1] Quinze Vingts Natl Ophthalmol Hosp, IHU FOReSIGHT, INSERM DGOS CIC 1423, 28 Rue Charenton, F-75012 Paris, France
[2] Gustave Roussy, Dept Biostat & Epidemiol, Villejuif, France
[3] Univ Paris Saclay, Univ Paris Sud, INSERM U1018, CESP, Villejuif, France
[4] Univ Paris Saclay, Univ Versailles St Quentin Yvelines, Ambroise Pare Hosp, AP HP,IHU FOReSIGHT,Dept Ophthalmol, Versailles, France
[5] Sorbonne Univ, CNRS, INSERM, Inst Vis,IHU FOReSIGHT, Paris, France
关键词
Glaucoma; VF testing; intraocular pressure; OPEN-ANGLE GLAUCOMA; ACCOMMODATION;
D O I
10.1186/s12886-020-01622-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background To evaluate the influence of automated visual field (VF) testing on intraocular pressure (IOP) in patients with ocular hypertension (OHT) or glaucoma. Methods We conducted a prospective observational study in the glaucoma department at Quinze-Vingts National Ophthalmology Hospital in Paris. Ninety-five right eyes of 95 patients followed for glaucoma or OHT were included. IOP was measured three times using a Nidek NT-510 non-contact tonometer within a maximum of 5 min before and after VF testing. Sub analyses using logistic regression analysis were performed to evaluate the impact of gender, age, central corneal thickness (CCT), mean deviation (MD) of the VF, VF test duration and filtration surgery on IOP fluctuations. Results There was no significant change in IOP after VF testing, with IOP's 15.14 +/- 4.00 mmHg before and 14.98 +/- 3.33 mmHg after the VF (P = 0.4). The average change in IOP was 0.15 +/- 1.82 mmHg. Using multivariate analysis, no effect of the VF test on IOP was found (global model fit R-2 = 0.12), whether based on duration of the VF test (P = 0.18) or the MD (P = 0.7) after adjustment for age, gender, CCT and history of glaucoma surgery. Similarly, there was no significant difference within different types of glaucoma, including open-angle glaucoma(P = 0.36),chronic angle closure glaucoma (P = 0.85) and OHT (P = 0.42). The subgroup of patients with an IOP elevation >= 2 mmHg had a significantly higher VF test duration (P = 0.002). Conclusion VF testing does not influence IOP as measured with a non-contact tonometer.
引用
收藏
页数:6
相关论文
共 22 条
[1]  
ARMALY MF, 1962, INVEST OPHTH VISUAL, V1, P480
[2]   AUTOMATED PERIMETRY IN GLAUCOMA [J].
CAPRIOLI, J .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1991, 111 (02) :235-239
[3]   Influence of mental and physical stress on intraocular pressure - a pilot study [J].
Erb, C ;
Brody, S ;
Rau, H .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1998, 212 (05) :270-274
[4]   Repeatability and Reproducibility of Measurements Using a NT-530P Noncontact Tono/Pachymeter and Correlation of Central Corneal Thickness with Intraocular Pressure [J].
Fujimura, Fusako ;
Kamiya, Kazutaka ;
Fujiwara, Kazuko ;
Shoji, Nobuyuki ;
Shimizu, Kimiya .
BIOMED RESEARCH INTERNATIONAL, 2013, 2013
[5]  
GALLAR J, 1993, INVEST OPHTH VIS SCI, V34, P596
[6]   CHANGES IN INTRAOCULAR PRESSURE DURING AND AFTER DARK-ROOM TEST [J].
GLOSTER, J ;
POINOOSA.D .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1973, 57 (03) :170-178
[7]   CONSEQUENCES OF EYELID SQUEEZING ON INTRA-OCULAR PRESSURE [J].
GREEN, K ;
LUXENBERG, MN .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1979, 88 (06) :1072-1077
[8]  
GREENE PR, 1980, AM J OPTOM PHYS OPT, V57, P902
[9]  
GRIGNOLO FM, 1977, KLIN MONATSBL AUGENH, V170, P562
[10]   Assessment of Visual Function in Glaucoma A Report by the American Academy of Ophthalmology [J].
Jampel, Henry D. ;
Singh, Kuldev ;
Lin, Shan C. ;
Chen, Teresa C. ;
Francis, Brian A. ;
Hodapp, Elizabeth ;
Samples, John R. ;
Smith, Scott D. ;
Collins, Nancy .
OPHTHALMOLOGY, 2011, 118 (05) :986-1002