Evaluation of the continuous dilatometer method of silicon carbide thermometry for passive irradiation temperature determination

被引:28
作者
Field, Kevin G. [1 ]
McDuffee, Joel L. [1 ]
Geringer, Josina W. [1 ]
Petrie, Christian M. [1 ]
Katoh, Yutai [1 ]
机构
[1] Oak Ridge Natl Lab, Oak Ridge, TN 37831 USA
关键词
Silicon carbide (SiC); Passive irradiation temperature monitor; Dilatometry; Annealing; DISLOCATION LOOP FORMATION; NEUTRON; MODEL; PRECIPITATION; ALPHA'; CALIBRATION; MONITORS; LENGTH;
D O I
10.1016/j.nimb.2019.02.022
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Silicon carbide (SiC) is a primary candidate for passive irradiation temperature monitoring, and continuous dilatometry (CD) has been proposed as the key method for extracting irradiation temperatures from SiC thermometry samples. The CD method was evaluated to determine the sensitivity of the technique to the analysis procedure, as well as its accuracy and precision. Analysis found that the CD method had a +/- 20 degrees C sensitivity to the algorithm used to determine the irradiation temperatures. Comparison of the CD method with the continuous length change method for SiC thermometry showed CD is a more viable method of extracting irradiation temperatures. A comparison of irradiation temperatures determined by CD with those from active thermocouple measurements further validated the CD method for accurately and precisely determining irradiation temperatures in materials test reactor irradiations.
引用
收藏
页码:46 / 56
页数:11
相关论文
共 37 条
[1]   Critical questions in materials science and engineering for successful development of fusion power [J].
Bloom, E. E. ;
Busby, J. T. ;
Duty, C. E. ;
Maziasz, P. J. ;
McGreevy, T. E. ;
Nelson, B. E. ;
Pint, B. A. ;
Tortorelli, P. F. ;
Zinkle, S. J. .
JOURNAL OF NUCLEAR MATERIALS, 2007, 367 :1-10
[2]   TEMPERATURE MONITORS FOR UNINSTRUMENTED IRRADIATION EXPERIMENTS [J].
BRAMMAN, JI ;
FRASER, AS ;
MARTIN, WH .
JOURNAL OF NUCLEAR ENERGY, 1971, 25 (06) :223-&
[3]   A combined APT and SANS investigation of α′ phase precipitation in neutron-irradiated model FeCrAl alloys [J].
Briggs, Samuel A. ;
Edmondson, Philip D. ;
Littrell, Kenneth C. ;
Yamamoto, Yukinori ;
Howard, Richard H. ;
Daily, Charles R. ;
Terrani, Kurt A. ;
Sridharan, Kumar ;
Field, Kevin G. .
ACTA MATERIALIA, 2017, 129 :217-228
[4]   Method for analyzing passive silicon carbide thermometry with a continuous dilatometer to determine irradiation temperature [J].
Campbell, Anne A. ;
Porter, Wallace D. ;
Katoh, Yutai ;
Snead, Lance L. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2016, 370 :49-58
[5]  
Davis K. L., 2012, INLCON1123913
[6]   Irradiation-enhanced α′ precipitation in model FeCrAl alloys [J].
Edmondson, P. D. ;
Briggs, S. A. ;
Yamamoto, Y. ;
Howard, R. H. ;
Sridharan, K. ;
Terrani, K. A. ;
Field, K. G. .
SCRIPTA MATERIALIA, 2016, 116 :112-116
[7]   University of Wisconsin Ion Beam Laboratory: A Facility for Irradiated Materials and Ion Beam Analysis [J].
Field, K. G. ;
Wetteland, C. J. ;
Cao, G. ;
Maier, B. R. ;
Dickerson, C. ;
Gerczak, T. J. ;
Field, C. R. ;
Kriewaldt, K. ;
Sridharan, K. ;
Allen, T. R. .
APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY, 2013, 1525 :159-164
[8]  
Field K. G., 2017, FUSION MAT RES
[9]   Dislocation loop formation in model FeCrAl alloys after neutron irradiation below 1 dpa [J].
Field, Kevin G. ;
Briggs, Samuel A. ;
Sridharan, Kumar ;
Yamamoto, Yukinori ;
Howard, Richard H. .
JOURNAL OF NUCLEAR MATERIALS, 2017, 495 :20-26
[10]   Precipitation of α′ in neutron irradiated commercial FeCrAl alloys [J].
Field, Kevin G. ;
Littrell, Kenneth C. ;
Briggs, Samuel A. .
SCRIPTA MATERIALIA, 2018, 142 :41-45