Comparison of the air kerma standards for 137Cs and 60Co gamma-ray beams between the IAEA and the NIST

被引:3
|
作者
Minniti, Ronaldo [1 ]
Czap, Ladislav [2 ]
机构
[1] NIST, Gaithersburg, MD 20899 USA
[2] IAEA, A-1400 Vienna, Austria
关键词
D O I
10.1088/0026-1394/48/1A/06005
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A comparison of the air kerma standards for Cs-137 and Co-60 gamma ray beams was performed between the NIST and the IAEA. Two reference class ionization chambers owned by the IAEA were used as part of this comparison and were calibrated at each facility. The calibration coefficients, N-K, were determined for both chambers and in both gamma-ray beams. The measurements were performed at the IAEA and NIST facilities starting in the fall of 2009 and were completed in 2010. The comparison ratio of the calibration coefficients for each chamber, N-K,N-IAEA/N-K,N-NIST, between the IAEA and NIST were 0.999 and 0.997 for the Cs-137 and Co-60 gamma ray beams respectively. The relative standard uncertainty for each of these ratios is 0.5 %.
引用
收藏
页数:8
相关论文
共 50 条
  • [2] Comparisons of the radiation protection standards for air kerma of the NIST and the BIPM for 60Co and 137Cs gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    Minniti, R.
    METROLOGIA, 2014, 51
  • [3] Comparisons of the standards for air kerma of the GUM and the BIPM for 60Co and 137Cs gamma radiation
    Allisy-Roberts, P. J.
    Kessler, C.
    Burns, D. T.
    Derlacinski, M.
    Kokocinski, J.
    METROLOGIA, 2011, 48
  • [4] Change of air kerma standards of the BEV for 137Cs and 60Co γ-rays
    Witzani, J
    Gabris, F
    Leitner, A
    METROLOGIA, 2004, 41 (01) : L1 - L2
  • [5] RE-EVALUATION OF THE AIR KERMA PRIMARY STANDARD OF THE SMU IN 60Co AND 137Cs GAMMA RAY BEAMS
    Durny, Norman
    RADIATION PROTECTION DOSIMETRY, 2019, 186 (2-3) : 235 - 238
  • [6] Comparison Between the NIST and the KEBS for the Determination of Air Kerma Calibration Coefficients for Narrow X-Ray Spectra and 137Cs Gamma-Ray Beams
    O'Brien, Michelle
    Minniti, Ronaldo
    Masinza, Stanslaus Alwyn
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2010, 115 (01) : 7 - 13
  • [7] Comparison of the standards for air kerma of the NIST and the BIPM for 60Co gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    Minniti, Ronaldo
    METROLOGIA, 2013, 50
  • [8] Comparison of the standards for air kerma of the KRISS and the BIPM for 137Cs gamma radiation
    Kessler, C.
    Roger, P.
    Allisy-Roberts, P. J.
    Yi, Chul-Young
    METROLOGIA, 2010, 47
  • [9] Comparison of the standards for air kerma of the BEV and the BIPM for 137Cs gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    Steurer, A.
    Tiefenboeck, W.
    Gabris, F.
    METROLOGIA, 2010, 47
  • [10] Comparison of the standards for air kerma of the MKEH and the BIPM for 137Cs gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    Csete, I.
    Machula, G.
    METROLOGIA, 2010, 47