A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets

被引:482
作者
Castillo, Richard [2 ]
Castillo, Edward [3 ]
Guerra, Rudy [4 ]
Johnson, Valen E. [5 ]
McPhail, Travis [6 ]
Garg, Amit K. [1 ]
Guerrero, Thomas [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
[3] Univ Calif Irvine, Dept Math, Irvine, CA 92717 USA
[4] Rice Univ, Dept Stat, Houston, TX 77251 USA
[5] Univ Texas MD Anderson Canc Ctr, Dept Biostat & Appl Math, Houston, TX 77030 USA
[6] Rice Univ, Dept Comp Sci, Houston, TX USA
关键词
RADIATION-THERAPY; OPTICAL-FLOW; MOTION ESTIMATION; COMPUTED-TOMOGRAPHY; LUNG MOTION; CT IMAGES; RADIOTHERAPY; NONLINEARITY; VALIDATION; SIMULATION;
D O I
10.1088/0031-9155/54/7/001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Expert landmark correspondences are widely reported for evaluating deformable image registration (DIR) spatial accuracy. In this report, we present a framework for objective evaluation of DIR spatial accuracy using large sets of expert-determined landmark point pairs. Large samples (> 1100) of pulmonary landmark point pairs were manually generated for five cases. Estimates of inter- and intra-observer variation were determined from repeated registration. Comparative evaluation of DIR spatial accuracy was performed for two algorithms, a gradient-based optical flow algorithm and a landmark-based moving least-squares algorithm. The uncertainty of spatial error estimates was found to be inversely proportional to the square root of the number of landmark point pairs and directly proportional to the standard deviation of the spatial errors. Using the statistical properties of this data, we performed sample size calculations to estimate the average spatial accuracy of each algorithm with 95% confidence intervals within a 0.5 mm range. For the optical flow and moving least-squares algorithms, the required sample sizes were 1050 and 36, respectively. Comparative evaluation based on fewer than the required validation landmarks results in misrepresentation of the relative spatial accuracy. This study demonstrates that landmark pairs can be used to assess DIR spatial accuracy within a narrow uncertainty range.
引用
收藏
页码:1849 / 1870
页数:22
相关论文
共 34 条
[1]   Contact surface and material nonlinearity modeling of human lungs [J].
Al-Mayah, A. ;
Moseley, J. ;
Brock, K. K. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (01) :305-317
[2]  
[Anonymous], 1995, VIS INTERFACE
[3]  
[Anonymous], 2008, Digital image processing
[4]   The computation of optical flow [J].
Beauchemin, SS ;
Barron, JL .
ACM COMPUTING SURVEYS, 1995, 27 (03) :433-467
[5]  
Bevington P.R., 2003, DATA REDUCTION ERROR, V3
[6]   4D-CT lung motion estimation with deformable registration: Quantification of motion nonlinearity and hysteresis [J].
Boldea, Vlad ;
Sharp, Gregory C. ;
Jiang, Steve B. ;
Sarrut, David .
MEDICAL PHYSICS, 2008, 35 (03) :1008-1018
[7]   Accuracy of finite element model-based multi-organ deformable image registration [J].
Brock, KK ;
Sharpe, MB ;
Dawson, LA ;
Kim, SM ;
Jaffray, DA .
MEDICAL PHYSICS, 2005, 32 (06) :1647-1659
[8]   Accuracy and sensitivity of finite element model-based deformable registration of the prostate [J].
Brock, Kristy K. ;
Nichol, Alan M. ;
Menard, Cynthia ;
Moseley, Joanne L. ;
Warde, Padraig R. ;
Catton, Charles N. ;
Jaffray, David A. .
MEDICAL PHYSICS, 2008, 35 (09) :4019-4025
[9]  
Casella G., 2001, Statistical Inference, V2nd
[10]   Mutual information based CT registration of the lung at exhale and inhale breathing states using thin-plate splines [J].
Coselmon, MM ;
Balter, JM ;
McShan, DL ;
Kessler, ML .
MEDICAL PHYSICS, 2004, 31 (11) :2942-2948