Activation of nylon net and its application to a biosensor for determination of glucose in human serum

被引:43
|
作者
Nan, Caifeng [1 ]
Zhang, Yan [1 ]
Zhang, Guomei [1 ]
Dong, Chuan [1 ]
Shuang, Shaomin [1 ]
Choi, Martin M. F. [2 ]
机构
[1] Shanxi Univ, Sch Chem & Chem Engn, Res Ctr Environm Sci & Engn, Taiyuan 030006, Peoples R China
[2] Hong Kong Baptist Univ, Dept Chem, Kowloon Tong, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
Glucose biosensor; Glucose oxidase; Nylon net; Activation; Glucose; EGGSHELL MEMBRANE; AMPEROMETRIC BIOSENSOR; LABORATORY EXPERIMENT; OXIDASE; IMMOBILIZATION; LACTATE; SENSOR; MICRODIALYSIS; FABRICATION; SYSTEM;
D O I
10.1016/j.enzmictec.2008.12.007
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A glucose biosensor using a glucose oxidase (GO(x))-immobilized nylon net with glutaraldehyde as cross-linking reagent and an oxygen (O-2) electrode for the determination of glucose has been fabricated. The detection scheme was based on the utilization of dissolved O-2 in oxidation of glucose by the membrane bound GO(x). Crucial factors including O-alkylation temperature, reaction times of nylon net with dimethyl Sulfate, L-lysine, and glutaraldehyde, and enzyme loading were examined to determine the optimal enzyme immobilization conditions for the best sensitivity of the developed glucose biosensor. In addition, the effects of pH and concentration of phosphate buffer on the response of the biosensor were Studied. The glucose biosensor had a linear range of 18 mu M to 1.10 mM with the detection limit of 9.0 mu M (S/N = 3) and response time of 80s. The biosensor exhibited both good operational stability with over 200 measurements and long-term storage stability. The results from this biosensor compared well with those of a commercial glucose assay kit in analyzing human serum glucose samples. (C) 2008 Elsevier Inc. All rights reserved
引用
收藏
页码:249 / 253
页数:5
相关论文
共 50 条
  • [41] HUMAN SERUM BILIRUBIN - AN IMMEDIATE METHOD OF DETERMINATION AND ITS APPLICATION TO THE ESTABLISHMENT OF NORMAL VALUES
    OHAGAN, JE
    HAMILTON, T
    LEBRETON, EG
    SHAW, AE
    CLINICAL CHEMISTRY, 1957, 3 (05) : 609 - 623
  • [42] Determination of biogenic amines with an electrochemical biosensor and its application to salted anchovies
    Draisci, R
    Volpe, G
    Lucentini, L
    Cecilia, A
    Federico, R
    Palleschi, G
    FOOD CHEMISTRY, 1998, 62 (02) : 225 - 232
  • [43] Synthesis, Characterization of a New Organosoluble Polyimide and Its Application in Development of Glucose Biosensor
    Pasahan, Aziz
    Koytepe, Suleyman
    Ekinci, Ergun
    POLYMER-PLASTICS TECHNOLOGY AND ENGINEERING, 2011, 50 (12) : 1239 - 1246
  • [44] Titanium dioxide-cellulose hybrid nanocomposite and its glucose biosensor application
    Maniruzzaman, Mohammad
    Jang, Sang-Dong
    Kim, Jaehwan
    MATERIALS SCIENCE AND ENGINEERING B-ADVANCED FUNCTIONAL SOLID-STATE MATERIALS, 2012, 177 (11): : 844 - 848
  • [45] NEW ENZYMATIC ASSAY FOR GLUCOSE DETERMINATION AND ITS APPLICATION
    CAVARI, BZ
    PHELPS, G
    ISRAEL JOURNAL OF MEDICAL SCIENCES, 1977, 13 (09): : 928 - 928
  • [46] Preparation, characterization and analytical application of an electrochemical laccase biosensor towards low level determination of isoprenaline in human serum samples
    Gopal, P.
    Reddy, T. Madhusudana
    Nagaraju, C.
    Narasimha, G.
    RSC ADVANCES, 2014, 4 (101) : 57591 - 57599
  • [47] Conducting polymer coated microelectrodes as biosensor devices: An application for pH and glucose determination.
    Oubda, T
    Zhao, P
    Nauer, GE
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1996, 212 : 79 - IEC
  • [48] THIN-FILM BIOSENSOR FOR THE MEASUREMENT OF GLUCOSE-CONCENTRATION IN HUMAN SERUM AND URINE
    YU, PG
    ZHOU, D
    ANALYTICA CHIMICA ACTA, 1995, 300 (1-3) : 91 - 97
  • [49] A disposable electrochemical biosensor for L-DOPA determination in undiluted human serum
    Brunetti, Barbara
    Valdes-Ramirez, Gabriela
    Litvan, Irene
    Wang, Joseph
    ELECTROCHEMISTRY COMMUNICATIONS, 2014, 48 : 28 - 31
  • [50] Application of potentiometric biosensor based on recombinant urease for urea determination in blood serum and hemodialyzate
    Marchenko, S. V.
    Kucherenko, I. S.
    Hereshko, A. N.
    Panasiuk, I. V.
    Soldatkin, O. O.
    El'skaya, A. V.
    Soldatkin, A. P.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 207 : 981 - 986