Activation of nylon net and its application to a biosensor for determination of glucose in human serum

被引:43
|
作者
Nan, Caifeng [1 ]
Zhang, Yan [1 ]
Zhang, Guomei [1 ]
Dong, Chuan [1 ]
Shuang, Shaomin [1 ]
Choi, Martin M. F. [2 ]
机构
[1] Shanxi Univ, Sch Chem & Chem Engn, Res Ctr Environm Sci & Engn, Taiyuan 030006, Peoples R China
[2] Hong Kong Baptist Univ, Dept Chem, Kowloon Tong, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
Glucose biosensor; Glucose oxidase; Nylon net; Activation; Glucose; EGGSHELL MEMBRANE; AMPEROMETRIC BIOSENSOR; LABORATORY EXPERIMENT; OXIDASE; IMMOBILIZATION; LACTATE; SENSOR; MICRODIALYSIS; FABRICATION; SYSTEM;
D O I
10.1016/j.enzmictec.2008.12.007
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A glucose biosensor using a glucose oxidase (GO(x))-immobilized nylon net with glutaraldehyde as cross-linking reagent and an oxygen (O-2) electrode for the determination of glucose has been fabricated. The detection scheme was based on the utilization of dissolved O-2 in oxidation of glucose by the membrane bound GO(x). Crucial factors including O-alkylation temperature, reaction times of nylon net with dimethyl Sulfate, L-lysine, and glutaraldehyde, and enzyme loading were examined to determine the optimal enzyme immobilization conditions for the best sensitivity of the developed glucose biosensor. In addition, the effects of pH and concentration of phosphate buffer on the response of the biosensor were Studied. The glucose biosensor had a linear range of 18 mu M to 1.10 mM with the detection limit of 9.0 mu M (S/N = 3) and response time of 80s. The biosensor exhibited both good operational stability with over 200 measurements and long-term storage stability. The results from this biosensor compared well with those of a commercial glucose assay kit in analyzing human serum glucose samples. (C) 2008 Elsevier Inc. All rights reserved
引用
收藏
页码:249 / 253
页数:5
相关论文
共 50 条
  • [31] Chronocoulometric determination of urea in human serum using an inkjet printed biosensor
    Suman
    O'Reilly, Emmet
    Kelly, Michele
    Morrin, Aoife
    Smyth, Malcolm R.
    Killard, Anthony J.
    ANALYTICA CHIMICA ACTA, 2011, 697 (1-2) : 98 - 102
  • [32] Direct fluorimetric determination of γ-globulin in human serum with organic nanoparticle biosensor
    Wang, LY
    Wang, L
    Dong, L
    Bian, GR
    Xia, TT
    Chen, HQ
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2005, 61 (1-2) : 129 - 133
  • [33] IMMOBILIZATION OF GLUCOSE-OXIDASE ON NYLON MEMBRANES AND ITS APPLICATION IN A FLOW-THROUGH GLUCOSE REACTOR
    DASILVA, MA
    GIL, MH
    REDINHA, JS
    BRETT, AMO
    PEREIRA, JLC
    JOURNAL OF POLYMER SCIENCE PART A-POLYMER CHEMISTRY, 1991, 29 (02) : 275 - 279
  • [34] A novel glucose biosensor based on palladium nanoparticles and its application in detection of glucose level in urine
    Zhang, FF
    Wan, Q
    Li, CX
    Zhu, ZQ
    Xian, YZ
    Jin, LT
    Yamamoto, K
    CHINESE JOURNAL OF CHEMISTRY, 2003, 21 (12) : 1619 - 1623
  • [35] A Novel Glucose Biosensor Based on Palladium Nanoparticles and Its Application in Detection of Glucose Level in Urine
    张芬芬
    万巧
    李陈鑫
    朱自强
    鲜跃仲
    金利通
    山本胜信
    ChineseJournalofChemistry, 2003, (12) : 1619 - 1623
  • [36] Determination of granulocyte colony stimulating factor and its antibody in human serum samples using the BIAcore 3000 biosensor
    Ahmad, A
    Zong, Q
    Rock, M
    McLean, M
    Breau, A
    ANALYTICAL BIOCHEMISTRY, 2004, 324 (02) : 304 - 306
  • [37] IMMOBILIZATION OF GLUCOSE OXIDASE IN SILICA SOL-GEL FILM FOR APPLICATION TO BIOSENSOR AND AMPEROMETRIC DETERMINATION OF GLUCOSE
    Demirkiran, Nizamettin
    Ekinci, Ergun
    Asilturk, Meltem
    JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2012, 57 (04) : 1336 - 1339
  • [38] Application of the amplified luminol chemiluminescence method for the determination of serum glucose
    Haviger, A
    Sevcik, J
    Stransky, Z
    CHEMICKE LISTY, 1996, 90 (09): : 738 - 739
  • [39] HUMAN SERUM BILIRUBIN - AN IMMEDIATE METHOD OF DETERMINATION AND ITS APPLICATION TO THE ESTABLISHMENT OF NORMAL VALUES
    OHAGAN, JE
    HAMILTON, T
    LEBRETON, HG
    SHAW, AE
    CLINICAL CHEMISTRY, 1956, 2 (04) : 239 - 240
  • [40] Development of vial wall sorptive extraction and its application to determination of progesterone in human serum
    Kawaguchi, Migaku
    Fujii, Shin-ichiro
    Itoh, Nobuyasu
    Ito, Rie
    Nakazawa, Hiroyuki
    Takatsu, Akiko
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (44) : 7553 - 7557