STARD 2015 guidelines for reporting diagnostic accuracy studies: explanation and elaboration

被引:1710
作者
Cohen, Jeremie F. [1 ,2 ]
Korevaar, Daniel A. [1 ]
Altman, Douglas G. [3 ]
Bruns, David E. [4 ]
Gatsonis, Constantine A. [5 ]
Hooft, Lotty [6 ]
Irwig, Les [7 ]
Levine, Deborah [8 ,9 ]
Reitsma, Johannes B. [10 ]
de Vet, Henrica C. W. [11 ]
Bossuyt, Patrick M. M. [1 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Clin Epidemiol Biostat & Bioinformat, Amsterdam, Netherlands
[2] Paris Descartes Univ, Necker Hosp, Dept Pediat, INSERM,UMR 1153, Paris, France
[3] Univ Oxford, Nuffield Dept Orthopaed Rheumatol & Musculoskelet, Ctr Stat Med, Oxford, England
[4] Univ Virginia, Sch Med, Dept Pathol, Charlottesville, VA 22908 USA
[5] Brown Univ, Sch Publ Hlth, Dept Biostat, Providence, RI 02912 USA
[6] Univ Utrecht, Univ Med Ctr Utrecht, Julius Ctr Hlth Sci & Primary Care, Cochrane Netherlands, Utrecht, Netherlands
[7] Univ Sydney, Sch Publ Hlth, Screening & Diagnost Test Evaluat Program, Sydney, NSW, Australia
[8] Beth Israel Deaconess Med Ctr, Dept Radiol, 330 Brookline Ave, Boston, MA 02215 USA
[9] Radiol Editorial Off, Boston, MA USA
[10] Univ Utrecht, Univ Med Ctr Utrecht, Julius Ctr Hlth Sci & Primary Care, Utrecht, Netherlands
[11] Vrije Univ Amsterdam Med Ctr, EMGO Inst Hlth & Care Res, Dept Epidemiol & Biostat, Amsterdam, Netherlands
关键词
FINE-NEEDLE-ASPIRATION; VERIFICATION BIAS; RANDOMIZED-TRIALS; SPECTRUM BIAS; DECISION RULE; PRIMARY-CARE; SAMPLE-SIZE; SENSITIVITY; TESTS; SPECIFICITY;
D O I
10.1136/bmjopen-2016-012799
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Diagnostic accuracy studies are, like other clinical studies, at risk of bias due to shortcomings in design and conduct, and the results of a diagnostic accuracy study may not apply to other patient groups and settings. Readers of study reports need to be informed about study design and conduct, in sufficient detail to judge the trustworthiness and applicability of the study findings. The STARD statement (Standards for Reporting of Diagnostic Accuracy Studies) was developed to improve the completeness and transparency of reports of diagnostic accuracy studies. STARD contains a list of essential items that can be used as a checklist, by authors, reviewers and other readers, to ensure that a report of a diagnostic accuracy study contains the necessary information. STARD was recently updated. All updated STARD materials, including the checklist, are available at http://www.equator-network.org/reporting-guidelines/stard. Here, we present the STARD 2015 explanation and elaboration document. Through commented examples of appropriate reporting, we clarify the rationale for each of the 30 items on the STARD 2015 checklist, and describe what is expected from authors in developing sufficiently informative study reports.
引用
收藏
页数:17
相关论文
共 119 条
[11]  
BEGG CB, 1986, J CHRON DIS, V39, P575
[12]   Sample size in studies on diagnostic accuracy in ophthalmology: a literature survey [J].
Bochmann, Frank ;
Johnson, Zoe ;
Azuara-Blanco, Augusto .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (07) :898-900
[13]   Using a dog's superior olfactory sensitivity to identify Clostridium difficile in stools and patients: proof of principle study [J].
Bomers, Marije K. ;
van Agtmael, Michiel A. ;
Luik, Hotsche ;
van Veen, Merk C. ;
Vandenbroucke-Grauls, Christina M. J. E. ;
Smulders, Yvo M. .
BMJ-BRITISH MEDICAL JOURNAL, 2012, 345
[14]  
Bossuyt PM, 2015, BMJ-BRIT MED J, V351, DOI [10.1136/bmj.h5527, 10.1148/radiol.2015151516, 10.1373/clinchem.2015.246280]
[15]   Diagnosis - Comparative accuracy: assessing new tests against existing diagnostic pathways [J].
Bossuyt, PM ;
Irwig, L ;
Craig, J ;
Glasziou, P .
BRITISH MEDICAL JOURNAL, 2006, 332 (7549) :1089-1092
[16]   Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD initiative [J].
Bossuyt, PM ;
Reitsma, JB ;
Bruns, DE ;
Gatsonis, CA ;
Glasziou, PP ;
Irwig, LM ;
Lijmer, JG ;
Moher, D ;
Rennie, D ;
de Vet, HCW .
CLINICAL CHEMISTRY, 2003, 49 (01) :1-6
[17]   Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD initiative [J].
Bossuyt, PM ;
Reitsma, JB ;
Bruns, DE ;
Gatsonis, CA ;
Glasziou, PP ;
Irwig, LM ;
Lijmer, JG ;
Moher, D ;
Rennie, D ;
de Vet, HCW .
ANNALS OF INTERNAL MEDICINE, 2003, 138 (01) :40-44
[18]   Bias in plain film reading performance studies [J].
Brealey, S ;
Scally, AJ .
BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (880) :307-316
[19]   The importance of work-up (verification) bias correction in assessing the accuracy of SPECT thallium-201 testing for the diagnosis of coronary artery disease [J].
Cecil, MP ;
Kosinski, AS ;
Jones, MT ;
Taylor, A ;
Alazraki, NP ;
Pettigrew, RI ;
Weintraub, WS .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 1996, 49 (07) :735-742
[20]   Increasing value and reducing waste: addressing inaccessible research [J].
Chan, An-Wen ;
Song, Fujian ;
Vickers, Andrew ;
Jefferson, Tom ;
Dickersin, Kay ;
Gotzsche, Peter C. ;
Krumholz, Harlan M. ;
Ghersi, Davina ;
van der Worp, H. Bart .
LANCET, 2014, 383 (9913) :257-266