Value of transbronchial needle aspiration combined with a rapid on-site evaluation of cytology in the diagnosis of pulmonary lesions

被引:4
|
作者
Liang, Long [1 ]
Duan, Hongxia [2 ]
Zhu, Huiyuan [3 ]
Yang, Huiqiong [3 ]
Li, Xuan [1 ]
Wang, Changhui [1 ]
Xie, Shuanshuan [1 ]
机构
[1] Tongji Univ, Shanghai Peoples Hosp 10, Dept Resp Med, Sch Med, Shanghai, Peoples R China
[2] Nantong Univ, Dept Oncol, Affiliated Hosp, Nantong, Peoples R China
[3] Tongji Univ, Shanghai Peoples Hosp 10, Dept Pathol, Sch Med, Shanghai, Peoples R China
关键词
rapid on-site evaluation; endobronchial ultrasound-guided transbronchial needle aspiration; pulmonary lesions; diagnostic yield; complications; ENDOSCOPIC ULTRASOUND; LUNG-CANCER; ACCURACY; UTILITY; BRONCHOSCOPY; BIOPSY; IMPACT;
D O I
10.3389/fmed.2022.922239
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundThe diagnostic value of rapid on-site evaluation (ROSE) of cytology during endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) remains controversial. The purpose of this study was to validate the value of ROSE during the EUBS-TBNA procedure in the diagnosis of pulmonary lesions (PLs). MethodsEnrolled in this study were 260 patients with nodules, masses, cavities, or inflammatory lesions on pulmonary CT images. They were assigned to undergo EBUS-TBNA with ROSE (n = 134) or without ROSE (n = 126). The diagnostic results of ROSE during EBUS-TBNA and the final pathologic reports were analyzed and compared by utilizing SPSS21.0 software to evaluate the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). In addition, we further explored whether the ROSE method during EBUS-TBNA would improve the diagnostic yield and reduce the incidence of complications. ResultsThe overall diagnostic yield of EBUS-TBNA for malignant diseases in the ROSE and the non-ROSE group were 29.9 and 11.1%, respectively. The sensitivity, specificity, PPV and NPV of the ROSE method during EBUS-TBNA were 97.4, 96.9, 92.5, and 98.90%, respectively. The result of the chi-square test effectively proved that ROSE operation during EBUS-TBNA contributes to the diagnosis of malignancy compared with the non-ROSE group (chi(2) = 13.858, P < 0.001). The number of punctures in the ROSE group was significantly lower than that in the non-ROSE group (P < 0.001). ConclusionROSE examination during EBUS-TBNA could effectively improve the diagnostic yield of malignant diseases compared with the non-ROSE group and reduce the number of intraoperative punctures, which is a clinical application worth popularizing.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Diagnostic Value of Rapid On-Site Evaluation for CT-Guided Percutaneous Fine Needle Aspiration in the Diagnosis of Pulmonary Occupying Lesions
    Peng, Tian-Feng
    Ren, Tao
    Wang, Han-Sheng
    Feng, Zhe-Xiang
    Wang, Mei-Fang
    BIOMED RESEARCH INTERNATIONAL, 2020, 2020
  • [2] Diagnostic yield of rapid on-site evaluation transbronchial needle aspiration versus conventional transbronchial needle aspiration: a single center experience
    Guarino, Carmine
    Mollica, Mariano
    Cesaro, Cristiano
    Costigliola, Adriano
    Micheli, Maria Carolina
    Corcione, Nadia
    La Cerra, Giuseppe
    Tranfa, Carmelindo
    Cirillo, Salvatore
    Smeraglio, Riccardo
    Salvi, Rosario
    MONALDI ARCHIVES FOR CHEST DISEASE, 2020, 90 (01) : 73 - 77
  • [3] The value of rapid on-site evaluation during endobronchial ultrasound-guided transbronchial needle aspiration in the diagnosis of mediastinal lesions
    Adel S. Bediwy
    Khaled Zamzam
    Mohamed Hantira
    Dalia El-Sharawy
    Ayman ElSaqa
    Yomna Zamzam
    Egyptian Journal of Bronchology, 2017, 11 (4) : 336 - 341
  • [4] The value of transbronchial needle aspiration in the diagnosis of peripheral pulmonary lesions
    Reichenberger, F
    Weber, J
    Tamm, M
    Bolliger, CT
    Dalquen, P
    Perruchoud, AP
    Solèr, M
    CHEST, 1999, 116 (03) : 704 - 708
  • [5] Utilization of rapid on-site evaluation (ROSE) in transbronchial needle aspiration (TBNA), it is not a simple statistical issue
    Li, Cai-Li
    Sun, Wen-Wen
    Feng, Jing
    Cao, Jie
    Zhang, Peng
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (07): : 13298 - 13308
  • [6] Impact of rapid on-site cytologic evaluation during transbronchial needle aspiration
    Baram, D
    Garcia, RB
    Richman, PS
    CHEST, 2005, 128 (02) : 869 - 875
  • [7] Value of rapid on-site evaluation for ultrasound-guided thyroid fine needle aspiration
    Jiang, Danni
    Zang, Yichen
    Jiang, Dandan
    Zhang, Xiaojuan
    Zhao, Cheng
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2019, 47 (02) : 626 - 634
  • [8] Feasibility and accuracy of rapid on-site evaluation of touch imprint cytology during transbronchial biopsy
    Shikano, Kohei
    Ishiwata, Tsukasa
    Saegusa, Fumie
    Terada, Jiro
    Sakayori, Masashi
    Abe, Mitsuhiro
    Kawasaki, Takeshi
    Ikari, Jun
    Kawata, Naoko
    Tada, Yuji
    Tatsumi, Koichiro
    JOURNAL OF THORACIC DISEASE, 2020, 12 (06) : 3057 - 3064
  • [9] Value of transbronchial needle aspiration in the diagnosis of lung lesions
    Arslan, Zeliha
    Ilgazli, Ahmet
    Yildiz, Kursat
    Bakir, Meryem
    Arslan, Sibel
    EURASIAN JOURNAL OF PULMONOLOGY, 2008, 10 (02) : 115 - 118
  • [10] Rapid on-site evaluation of axillary fine-needle aspiration cytology in breast cancer
    O'Leary, D. P.
    O'Brien, O.
    Relihan, N.
    McCarthy, J.
    Ryan, M.
    Barry, J.
    Kelly, L. M.
    Redmond, H. P.
    BRITISH JOURNAL OF SURGERY, 2012, 99 (06) : 807 - 812