Relationship Between Oxygen Saturation and Umbilical Cord pH Immediately After Birth

被引:7
作者
Uslu, Sinan [1 ]
Bulbul, Ali [1 ]
Can, Emrah [1 ]
Zubarioglu, Umut [2 ]
Salihoglu, Ozgul [3 ]
Nuhoglu, Asiye [1 ]
机构
[1] Sisli Etfal Children Hosp, Div Neonatol, Dept Pediat, TR-34360 Istanbul, Turkey
[2] Sisli Children Hosp, Div Neonatol, Dept Pediat, Istanbul, Turkey
[3] Bakirkoy Sadi Konuk Educ & Res Hosp, Div Neonatol, Dept Pediat, Istanbul, Turkey
关键词
delivery room; newborn; oxygen saturation; umbilical cord blood pH; BLOOD-GAS ANALYSIS; NEONATAL RESUSCITATION; OXIDATIVE STRESS; PULSE OXIMETRY; ACID-BASE; CARDIOPULMONARY-RESUSCITATION; 100-PERCENT OXYGEN; TERM INFANTS; ARTERIAL; NEWBORN;
D O I
10.1016/j.pedneo.2012.08.005
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background: The aim of this study is to determine the relationship between oxygen saturation (SpO(2)) by pulse oximetry levels and umbilical cord arterial pH values in healthy newborns during the first 15 minutes of life. Methods: The study was performed with healthy term, appropriate-for-gestational-age newborn infants. The infants were divided in two groups: umbilical cord arterial blood pH value <= 7.19 (group 1) and >7.19 (group 2); SpO(2) levels during the first 15 minutes of life were compared between groups. Results: The study was completed with 129 infants (33 in group 1 and 96 in group 2). A significant correlation was found between first-measured preductal and postductal SpO(2) levels by pulse oximetry and umbilical cord arterial plivalues ([r(2):0.72(0.62-0.79); p<0.0011 and [r(2):0.32(0.25-0.54); p<0.001], respectively). In group 1, infants had lower SpO(2) levels at both preductal and postductal measurements during the first 11 minutes of life and time to reach >90% SpO(2) level was longer compared with infants in group 2. Conclusion: Determination of umbilical arterial blood pH values, in addition to clinical findings and oxygen saturation measurements, might be helpful in deciding the concentration of oxygen and whether or not to continue oxygen supplementation in the delivery room. Copyright (C) 2012, Taiwan Pediatric Association. Published by Elsevier Taiwan LLC. All rights reserved.
引用
收藏
页码:340 / 345
页数:6
相关论文
共 40 条
  • [1] ACOG Committee on Obstetric Practice, 2006, Obstet Gynecol, V108, P1319
  • [2] AHA/AAP Neonatal Resuscitation Program Steering Committee, 2006, TXB NEONATAL RESUSCI
  • [3] Low fetal oxygen saturation at birth and acidosis
    Arikan, GM
    Scholz, HS
    Haeusler, MCH
    Giuliani, A
    Haas, J
    Weiss, PAM
    [J]. OBSTETRICS AND GYNECOLOGY, 2000, 95 (04) : 565 - 571
  • [4] Meconium aspiration syndrome in term neonates with normal acid-base status at delivery: Is it different?
    Blackwell, SC
    Moldenhauer, J
    Hassan, SS
    Redman, ME
    Refuerzo, JS
    Berry, SM
    Sorokin, Y
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2001, 184 (07) : 1422 - 1426
  • [5] Outcomes among term infants when two-hour postnatal pH is compared with pH at delivery
    Casey, BM
    Goldaber, KG
    McIntire, DD
    Leveno, KJ
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2001, 184 (03) : 447 - 450
  • [6] Air or oxygen for neonatal resuscitation at birth?
    Chabernaud, J-L
    [J]. ARCHIVES DE PEDIATRIE, 2009, 16 (08): : 1194 - 1201
  • [7] Umbilical artery blood gases in healthy term newborn infants
    Dudenhausen, JW
    Luhr, C
    Dimer, JS
    [J]. INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 1997, 57 (03) : 251 - 258
  • [8] Intrauterine asphyxia: Clinical implications for providers of intrapartum care
    Fahey, J
    King, TL
    [J]. JOURNAL OF MIDWIFERY & WOMENS HEALTH, 2005, 50 (06) : 498 - 506
  • [9] CORRELATIONS BETWEEN OBSTETRIC CLINICAL EVENTS AND UMBILICAL-CORD BLOOD ACID-BASE AND BLOOD-GAS VALUES
    GOLDABER, KG
    GILSTRAP, LC
    [J]. CLINICAL OBSTETRICS AND GYNECOLOGY, 1993, 36 (01) : 47 - 59
  • [10] CHANGES IN ARTERIAL OXYGEN-SATURATION IMMEDIATELY AFTER BIRTH IN THE HUMAN NEONATE
    HARRIS, AP
    SENDAK, MJ
    DONHAM, RT
    [J]. JOURNAL OF PEDIATRICS, 1986, 109 (01) : 117 - 119