Characterization of mixtures of biocidal oligoguanidines by capillary electrophoresis and high-performance liquid chromatography coupled to mass spectrometry

被引:5
作者
Buchberger, Wolfgang W. [1 ]
Hattinger, Ingrid [1 ]
Hirnmelsbach, Markus [1 ]
机构
[1] Johannes Kepler Univ Linz, Inst Analyt Chem, A-4040 Linz, Austria
关键词
Oligomeric guanidines; Liquid chromatography; Capillary electrophoresis; Mass spectrometry; Structure elucidation;
D O I
10.1016/j.chroma.2008.11.023
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The polycondensation of guanidine hydrochloride and 2,2'-(ethylenedioxy)bis(ethylamine) leads to various types of oligomeric guanidines exhibiting a broad spectrum of biocidal activities. In the present work a reversed-phase high-performance liquid chromatographic method with a gradient consisting of aqueous 0.1% trifluoroacetic acid and acetonitrile as mobile phase has been developed to separate these oligoguanidines according to type and chain length. The combination with electrospray mass spectrometry allowed the identification of the various Compounds. By this technique, some structures already suggested in the literature could be confirmed, and several additional oligoguanidines not yet reported could be identified. As a complementary technique, capillary zone electrophoresis was investigated. Best results were obtained with carrier electrolytes consisting of phosphoric acid in water/acetonitrile mixtures. Although the number of peaks that could be separated by the electrophoretic method was considerably lower than in case of the chromatographic method, capillary electrophoresis in combination with UV detection at 195 nm may still be a fast method suitable for quantitation of some of the major compounds and for monitoring the reaction rate during the polycondensation reaction. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:113 / 118
页数:6
相关论文
共 7 条
[1]   Determination of chlorhexidine digluconate and polyhexamethylene biguanide in eye drops by capillary electrophoresis with contactless conductivity detection [J].
Abad-Villar, EM ;
Etter, SF ;
Thiel, MA ;
Hauser, PC .
ANALYTICA CHIMICA ACTA, 2006, 561 (1-2) :133-137
[2]   Evaluation of trifluoroacetic acid as an ion-pair reagent in the separation of small ionizable molecules by reversed-phase liquid chromatography [J].
Cai, B ;
Li, JW .
ANALYTICA CHIMICA ACTA, 1999, 399 (03) :249-258
[3]   Analysis of guazatine mixture by LC and LC-MS and antimycotic activity determination of principal components [J].
Dreassi, Elena ;
Zizzari, Alessandra Tania ;
D'Arezzo, Silvia ;
Visca, Paolo ;
Botta, Maurizio .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (04) :1499-1506
[4]   Structural characterization of biocidal oligoguanidines [J].
Feiertag, P ;
Albert, M ;
Ecker-Eckhofen, EM ;
Hayn, G ;
Hönig, H ;
Oberwalder, HW ;
Saf, R ;
Schmidt, A ;
Schmidt, O ;
Topchiev, D .
MACROMOLECULAR RAPID COMMUNICATIONS, 2003, 24 (09) :567-570
[5]   Studies of signal suppression in liquid chromatography-electrospray ionization mass spectrometry using volatile ion-pairing reagents [J].
Gustavsson, SA ;
Samskog, J ;
Markides, KE ;
Långström, B .
JOURNAL OF CHROMATOGRAPHY A, 2001, 937 (1-2) :41-47
[6]   Determination of polyhexamethyleneguanidine by capillary electrophoresis [J].
Rudnev, A. V. ;
Dzherayan, T. G. .
JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 61 (10) :1002-1005
[7]   Synthesis and antimicrobial activity of polymeric guanidine and biguanidine salts [J].
Zhang, YM ;
Jiang, JM ;
Chen, YM .
POLYMER, 1999, 40 (22) :6189-6198