Subendocardial steal effect seen with real-time perfusion imaging at low emission power during adenosine stress: Replenishment M-mode processing allows visualization of vertical steal

被引:3
作者
Tiemann, K [1 ]
Ghanem, A [1 ]
Schlosser, T [1 ]
Ehlgen, A [1 ]
Kuntz-Hehner, S [1 ]
Haushofer, M [1 ]
Bimmel, D [1 ]
Borovac, M [1 ]
Nanda, NC [1 ]
Omran, H [1 ]
Becher, H [1 ]
机构
[1] Univ Bonn, Dept Cardiol, D-53105 Bonn, Germany
来源
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES | 2001年 / 18卷 / 08期
关键词
myocardial contrast echocardiography; real-time perfusion imaging; parametric imaging; replenishment M-mode processing; subendocardial steal effect; vertical steal;
D O I
10.1046/j.1540-8175.2001.00689.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We present a patient in whom power pulse inversion imaging clearly demonstrated a subendocardial myocardial perfusion defect during contrast vasodilator stress using adenosine. The defect was best appreciated with M-mode postprocessing of power pulse inversion imaging data.
引用
收藏
页码:689 / 694
页数:6
相关论文
共 11 条
[1]   Mechanisms of limited maximum coronary flow in severe single-vessel coronary artery disease in humans due to vertical steal [J].
Hamasaki, S ;
Arima, S ;
Fukumoto, N ;
Yamaguchi, T ;
Nakano, F ;
Kamekou, M ;
Kihara, K ;
Shono, H ;
Nakao, S ;
Tanaka, H .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (12) :1597-+
[2]   Assessment of myocardial perfusion by harmonic power Doppler imaging at rest and during adenosine stress comparison with 99mTc-Sestamibi SPECT imaging [J].
Heinle, SK ;
Noblin, J ;
Goree-Best, P ;
Mello, A ;
Ravad, G ;
Mull, S ;
Mammen, P ;
Grayburn, PA .
CIRCULATION, 2000, 102 (01) :55-60
[3]  
KUNTZHEHNER S, IN PRESS RADIOLOGY
[4]  
Lentz C., 1999, European Heart Journal, V20, P33
[5]  
SCHLOSSER T, IN PRESS ULTRASOUND
[6]   Pulse inversion Doppler: A new method for detecting nonlinear echoes from microbubble contrast agents [J].
Simpson, DH ;
Chin, CT ;
Burns, PN .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (02) :372-382
[7]   Stimulated acoustic emission: Pseudo-Doppler shifts seen during the destruction of nonmoving microbubbles [J].
Tiemann, K ;
Pohl, C ;
Schlosser, T ;
Goenechea, J ;
Bruce, M ;
Veltmann, C ;
Kuntz, S ;
Bangard, M ;
Becher, H .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (07) :1161-1167
[8]   Real-time contrast echo assessment of myocardial perfusion at low emission power:: First experimental and clinical results using power pulse inversion imaging [J].
Tiemann, K ;
Lohmeier, S ;
Kuntz, S ;
Köster, J ;
Pohl, C ;
Burns, P ;
Porter, TR ;
Nanda, NC ;
Lüderitz, B ;
Becher, H .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1999, 16 (08) :799-809
[9]  
TIEMANN K, 2000, EUR J ECHOCARDIOG S1, V1, P56
[10]  
TIEMANN K, 2001, Z KARDIOL S2, V90